Specifications

Manufacturer

Bradford White®

Capacity

75 U.S. gal
62
Imp. gal
284
L

Input Power

155000 BTU/hr
45.4
kW·h

First Hour Delivery at 100 ºF Temperature Rise

208

First Hour Delivery at 56 ºC Temperature Rise

787

Water Connection Type (Imperial)

Front
Top

Water Connection Type (Metric)

Front
Top

Gas Connection Diameter

3/4 in
19
mm

Relief Valve Opening

3/4 in
19
mm

Standard Approximate Shipping Weight

520 lb
236
kg

Type

Liquid Propane Gas

Style

Flue Damper Electronic Ignition

Size

C

Test Pressure

300 psi
2068
kPa

Working Pressure

150 psi
1034
kPa

Available Kits

239-81764-00

Industry Standards

AGA/CGA
AHRI Certified®

ANSI Standards Z-21.10.3

ASME Certified

CSA® Certified

NSF


Maximum Recovery

Recovery at 40 ºF Degree Rise

View
389 gal/h

Recovery at 22 ºC Degree Rise

View
1431 L/h

Recovery at 100 ºF Degree Rise

View
155 gal/h

Recovery at 56 ºC Degree Rise

View
572 L/h

Recovery at 140 ºF Degree Rise

View
111 gal/h

Recovery at 78 ºC Degree Rise

View
409 L/h


Dimensions

Schematic

Top Vent Height A

72-1/4 in
1835
mm

Jacket Diameter B

28-1/4 in
718
mm

Vent Diameter C

6 in
152
mm

Front Hot Water Connection D

54-1/2 in
1384
mm

Floor to Gas Connection E

4-3/4 in
121
mm

Front Cold Water Connection F

34 in
864
mm

Floor to Top of Heater H

65 in
1651
mm

Floor to Top Water Connection J

67-1/8 in
1705
mm

Water Connection

1-1/2 in
38
mm


General Information
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.



Warranty
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.




Features
The Commercial Flue Damper Models feature:
  • ICON HD™ - Intelligent proven design combines temperature control, diagnostic codes, and system ignition functions into a single control board with a digital LCD display. Control panel cover tilts down for ease of wiring and service.
  • Operation Mode - Two different digitally displayed operation modes have the capability of adjusting the temperature setting up to 180 ºF (82 ºC), and adjusting the degree setting (ºF to ºC, or ºC to ºF).
  • Service Mode - Eight different digitally displayed service modes can be easily cycled through by pressing the select button. There is the capability of adjusting the temperature setting up to 180 ºF (82 ºC), adjusting the degree setting (ºF to ºC, or ºC to ºF), locking the maximum temperature setting that can be adjusted in operation mode, displaying the average water temperature (if water heater has two sensors), displaying the upper temperature sensor, displaying the lower temperature sensor, displaying flame current of the pilot flame, and displaying diagnostic codes.
  • Electronic Ignition - High voltage, low current electricity is sent to the pilot electrode initiating a spark to ignite the pilot gas. This results in savings pilot gas during stand-by periods because the pilot flame only operates when there's a call for heat.
  • Automatic Flue Damper - Reduces stand-by loss, saving gas consumption and improving overall efficiency.
  • Factory Installed Hydrojet® Sediment Reduction System - Cold water inlet sediment reducing device helps prevent sediment build up in the tank.
  • Vitraglas® Lining - Bradford White tanks are lined with an exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to steel surface by firing at a temperature of over 1600 ºF (871 ºC).
  • Non-CFC Foam Insulation - Covers the sides and top of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
  • Water Connections - Factory installed true dielectric waterway fittings extend water heater life and eases installation. Multiple water connection locations allow for greater installation flexibility.
  • Hand Hole Cleanout - Allows inspection of tank interior and facilitates removal of sediment deposits.
  • E.C.O. - An automatic re-set Energy Cut Off (E.C.O) shuts off all gas in event of an overheat condition. This automatically re-sets when operation conditions are back to normal.
  • Magnesium Anode Rods - Provide added protection against corrosion long trouble-free service.
  • Sanitizing Capability - Temperature setting up to 180 ºF (82 ºC).
  • ASME Code Available on all Models Above 200,000 BTU/Hr.
  • NSF Construction Available.
  • Low NOx Construction Available.
  • North Carolina Code Compliant.
  • T&P Relief Valve - Installed.
  • Brass Drain Valve - Tamper proof.
  • Design certified by CSA International.




Note
Power Vent Kits Available

Amperage Draw = 0.5 for damper models/less than 4 for induced draft models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed



 MORE IMAGES 

·  Standards for Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters

·  Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters - 3

·  Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters - 4

·  Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters - Model D-75T-(125,160)


 DOWNLOADS 

Brochure for Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters
(PDF, 709KB)


^