Catalog
Commercial Electric Water Heaters
American® Water Heater Company Electric Commercial Water Heaters
All commercial electric units have a Fused Ceramic Shield applied under pressure and fired at 1600 ºF to completely cover the tank interior. This provides a tough interior surface for storage tanks and maximum protection against the wearing effects of high-volume and high-temperature water.
Item # |
Capacity |
Element Power |
Full Load Current Single Phase 240 V |
Full Load Current Single Phase 277 V |
Add To Cart/Request Quote |
---|---|---|---|---|---|
LDCE32-50R-5500W | Capacity N/A 50 gal | Element Power N/A 5500 W | Full Load Current Single Phase 240 V N/A 22.9 A | Full Load Current Single Phase 277 V N/A 19.9 A | Request Quote |
LDCE32-65H-5500W | Capacity N/A 65 gal | Element Power N/A 5500 W | Full Load Current Single Phase 240 V N/A 22.9 A | Full Load Current Single Phase 277 V N/A 19.9 A | Request Quote |
LDCE32-80H-5500W | Capacity N/A 80 gal | Element Power N/A 5500 W | Full Load Current Single Phase 240 V N/A 22.9 A | Full Load Current Single Phase 277 V N/A 19.9 A | Request Quote |
LDCE32-119R-5500W | Capacity N/A 119 gal | Element Power N/A 5500 W | Full Load Current Single Phase 240 V N/A 22.9 A | Full Load Current Single Phase 277 V N/A 19.9 A | Request Quote |
LDCE32-30H-6000W | Capacity N/A 30 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-40R-6000W | Capacity N/A 40 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-50R-6000W | Capacity N/A 50 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-65H-6000W | Capacity N/A 65 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-80H-6000W | Capacity N/A 80 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-119R-6000W | Capacity N/A 119 gal | Element Power N/A 6000 W | Full Load Current Single Phase 240 V N/A 25 A | Full Load Current Single Phase 277 V N/A 21.7 A | Request Quote |
LDCE32-30H-7000W | Capacity N/A 30 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-40R-7000W | Capacity N/A 40 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-50R-7000W | Capacity N/A 50 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-65H-7000W | Capacity N/A 65 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-80H-7000W | Capacity N/A 80 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-119R-7000W | Capacity N/A 119 gal | Element Power N/A 7000 W | Full Load Current Single Phase 240 V N/A 29.2 A | Full Load Current Single Phase 277 V N/A 25.3 A | Request Quote |
LDCE32-30H-8000W | Capacity N/A 30 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-40R-8000W | Capacity N/A 40 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-50R-8000W | Capacity N/A 50 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-65H-8000W | Capacity N/A 65 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-80H-8000W | Capacity N/A 80 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-119R-8000W | Capacity N/A 119 gal | Element Power N/A 8000 W | Full Load Current Single Phase 240 V N/A 33.3 A | Full Load Current Single Phase 277 V N/A 28.9 A | Request Quote |
LDCE32-30H-9000W | Capacity N/A 30 gal | Element Power N/A 9000 W | Full Load Current Single Phase 240 V N/A 37.5 A | Full Load Current Single Phase 277 V N/A 32.5 A | Request Quote |
LDCE32-40R-9000W | Capacity N/A 40 gal | Element Power N/A 9000 W | Full Load Current Single Phase 240 V N/A 37.5 A | Full Load Current Single Phase 277 V N/A 32.5 A | Request Quote |
LDCE32-50R-9000W | Capacity N/A 50 gal | Element Power N/A 9000 W | Full Load Current Single Phase 240 V N/A 37.5 A | Full Load Current Single Phase 277 V N/A 32.5 A | Request Quote |