Catalog
Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters
Bradford White® NON NOx Commercial Water Heaters
Unit of Measure
Items |
/ImgCustom/1002/placeholder_notavailable.gif PDV-80S-150-3N Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif PDV-80S-200-3N Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif PDV-80S-250-3NA Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif PDV-80S-150-3X Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif PDV-80S-200-3X Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Model Type | N/A | |||||||||
Capacity | N/A 80 U.S. gal66 Imp. gal303 L | |||||||||
Input Power | N/A 150000 BTU/hr43.9 kW | N/A 199999 BTU/hr58.6 kW | N/A 250000 BTU/hr73.3 kW | N/A 150000 BTU/hr43.9 kW | N/A 199999 BTU/hr58.6 kW | |||||
Recovery at 40 ºF Degree Rise | N/A 364 gal/h | N/A 485 gal/h | N/A 606 gal/h | N/A 364 gal/h | N/A 485 gal/h | |||||
Recovery at 4.4 ºC Degree Rise | N/A 1378 L/h | N/A 1836 L/h | N/A 2294 L/h | N/A 1378 L/h | N/A 1836 L/h | |||||
Recovery at 100 ºF Degree Rise | N/A 145 gal/h | N/A 194 gal/h | N/A 242 gal/h | N/A 145 gal/h | N/A 194 gal/h | |||||
Recovery at 56 ºC Degree Rise | N/A 549 L/h | N/A 734 L/h | N/A 916 L/h | N/A 549 L/h | N/A 734 L/h | |||||
Recovery at 140 ºF Degree Rise | N/A 104 gal/h | N/A 139 gal/h | N/A 173 gal/h | N/A 104 gal/h | N/A 139 gal/h | |||||
Recovery at 60 ºC Degree Rise | N/A 394 L/h | N/A 526 L/h | N/A 655 L/h | N/A 394 L/h | N/A 526 L/h | |||||
Schematic |
N/A
Schematic Drawing for Commercial Power Direct Vent Independent Vent Energy Saver Gas Water Heaters |
|||||||||
Floor to Top of Heater A | N/A 63-7/8 in1603 mm | |||||||||
Jacket Diameter B | N/A 28-1/4 in718 mm | |||||||||
Vent Size C | N/A 3 in76 mm | N/A 3 in76 mm | N/A 4 in102 mm | N/A 3 in76 mm | N/A 3 in76 mm | |||||
Floor to Gas Connection D | N/A 17-3/8 in438 mm | |||||||||
Front Cold Water Connection E | N/A 20-3/4 in525 mm | |||||||||
Front Hot Water Connection F | N/A 51-3/8 in1303 mm | |||||||||
Floor to Top Water Connection G | N/A 65-3/4 in1654 mm | |||||||||
Floor to Vent Connection H | N/A 68-7/8 in1732 mm | N/A 68-7/8 in1732 mm | N/A 68-7/8 in1856 mm | N/A 68-7/8 in1732 mm | N/A 68-7/8 in1732 mm | |||||
Depth K | N/A 43-7/8 in1117 mm | |||||||||
Standard Approximate Shipping Weight | N/A 645 lb293 kg | |||||||||
ASME Approximate Shipping Weight | N/A | N/A | N/A 720 lb327 kg | N/A | N/A | |||||
Maximum Intake Length for 3" Vent Pipe | N/A 45 ft | N/A 45 ft | N/A | N/A 45 ft | N/A 45 ft | |||||
Maximum Exhaust Length for 3" Vent Pipe | N/A 45 ft | N/A 45 ft | N/A | N/A 45 ft | N/A 45 ft | |||||
Maximum Intake Length for 4" Vent Pipe | N/A 60 ft | |||||||||
Maximum Exhaust Length for 4" Vent Pipe | N/A 60 ft | |||||||||
Style | N/A Power Direct Independent Vent | |||||||||
Size | N/A C | |||||||||
Type | N/A Natural Gas | N/A Natural Gas | N/A Natural Gas | N/A Liquid Propane Gas | N/A Liquid Propane Gas | |||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Industry Standards | N/A AHRI Certified® ANSI Standards Z-21.10.3 ASME Certified CSA® Certified NSF | |||||||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. |
|||||||||
Features |
N/A
The Power Direct Vent Independent Vent Models feature:
|
|||||||||
Warranty |
N/A
|
|||||||||
Note | N/A Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency. | N/A Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency. |
N/A
ASME code available. Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency. |
N/A Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency. | N/A Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency. | |||||
|