Catalog
Heavy Duty Surface Thermostat Commercial Electric - The STCE31 models are designed to provide years of reliable operation in commercial applications. Multiple anodes promote longer tank life through even distribution, for protection of the new tank interior.
Unit of Measure

Specifications

Manufacturer

N/A American® Water Heater Company

Input Power

N/A 12 kW13.5 kW15 kW18 kW24 kW27 kW30 kW36 kW40.5 kW45 kW54 kW6 kW9 kW

Capacity

N/A 119 gal

Water Connection

N/A 1-1/4 in

Approximate Shipping Weight

N/A 390 lb

Working Pressure

N/A 150 psi1034 kPa

Finish

N/A Baked Enamel

Equipment Grade

N/A Commercial

Industry Standards

N/A ASHRAE 90.1b-1992 ASHRAE/IESNA 90.1-2004 ASME Optional UL® Listed

Maximum Recovery (ºF) 54 kW Input

Recovery at 30 ºF Temperature Rise

N/A 738 gal/h

Recovery at 40 ºF Temperature Rise

N/A 554 gal/h

Recovery at 50 ºF Temperature Rise

N/A 443 gal/h

Recovery at 60 ºF Temperature Rise

N/A 359 gal/h

Recovery at 70 ºF Temperature Rise

N/A 316 gal/h

Recovery at 80 ºF Temperature Rise

N/A 277 gal/h

Recovery at 90 ºF Temperature Rise

N/A 246 gal/h

Recovery at 100 ºF Temperature Rise

N/A 221 gal/h

Recovery at 110 ºF Temperature Rise

N/A 201 gal/h

Recovery at 120 ºF Temperature Rise

N/A 185 gal/h

Recovery at 130 ºF Temperature Rise

N/A 170 gal/h

Recovery at 140 ºF Temperature Rise

N/A 158 gal/h

Electrical Characteristics

Standard Voltage

N/A 208 V240 V277 V480 V

Phase

N/A Single Three

Dimensions

Schematic

N/A
Schematic Drawing for Heavy Duty STCE31 Series Commercial Electric Water Heaters

Height Top of Heater A

N/A 62-1/4 in

Width B

N/A 29-1/2 in

Depth C

N/A 35 in

Features

Features

N/A
  • Gold Plated Elements - The STCE models ship with gold plated elements. These gold elements provide long life and superior scale resistance.
  • Glass-Lined Tank - Three sizes; 50, 80, and 119 gallon capacity. Tank interior is coated with glass specially developed for water heater use. Tanks rated at 150 psi (1034 kPa) working pressure (ASME 150 psi). Foam insulation reduces costly heat loss, and is vermin proof.
  • Fusing - Protects all elements, thermostats, and internal wiring circuits against excess current flow. Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps.
  • Standard Voltages - 208, 240, and 480 V single-phase and three-phase delta. Convertible from three-phase to single-phase (in field) and vice versa. 277 V single-phase also available.
  • Terminal Block - Factory installed. Just bring the service to the heater and connect to block.
  • Controls - One temperature control (adjustable through a range of 120 to 180 ºF) and manual reset high temperature cut-off per element. Thermostat step control may be achieved by varying settings on individual temperature controls. Located behind hinged control compartment door for quick, easy access.

Testing and Certifications

Testing and Certifications

N/A Meets or exceeds the requirements of ASHRAE 90.1b 1992 and ASHRAE/IESNA 90.1-2004.

Other Standard Features

Other Standard Features

N/A
  • Simplified circuitry, color coded for ease of service
  • Two anode rods for maximum corrosion protection
  • Cabinet has bonderized undercoat with baked enamel finish
  • Bottom inlet and top outlet openings
  • Brass drain valve
  • CSA®/ASME temperature and pressure relief valve
  • Single panel control box

Options

Options

N/A
  • UL listed conversion kits to correct some voltage and kW requirements in the field before and after installation
  • ASME 150 psi tank construction
  • International voltages - 220, 380, 400, 415, 575, and 600 volts, three phase available with Y connected elements
  • Manifold Kits - for multiple tank installations. Two heaters - part #9003429205, three heaters part #9003430205 and four heaters - part #9003431205

Warranty

Warranty

N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.

Note

Note

N/A Elements available in incoloy only.

208 V models may contain three (3) additional elements.