Print Back
Unit of Measure

Specifications

Manufacturer

N/A American® Water Heater Company

Input Power

N/A 310000 KBTU/hr91 kW

Capacity

N/A 85 U.S. gal322 L

Thermal Efficiency

N/A 82 %

Standard Type

N/A Non-ASME

Minimum Gas Supply Pressure

N/A 0.87 kPa3.50 inWc

Maximum Gas Supply Pressure

N/A 14 inWc3.48 kPa

Standard Approximate Shipping Weight

N/A 850 lb386 kg

Options

N/A
  • Meets NSF Standard 5 with optional leg kit - Part #9008214005

Type

N/A Natural Gas

Style

N/A Ultra-Low NOx Heavy-Duty

Size

N/A C

Industry Standards

N/A AHRI Certified® ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed

Dimensions

Schematic

N/A
Schematic Drawing for Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Dimension A

N/A 76 in193 cm

Dimension B

N/A 16-1/4 in41.2 cm

Dimension C

N/A 78-1/4 in198.8 cm

Dimension D

N/A 65-3/4 in167 cm

Dimension E

N/A 25-3/4 in65.4 cm

Dimension F

N/A 21 in53.3 cm

Dimension G

N/A 3/4 in. NPT

Dimension H

N/A 66-1/4 in168.3 cm

Dimension I

N/A 6 in15.2 cm

Dimension J

N/A 27-3/4 in70.5 cm

Dimension K

N/A 1-1/2 in. NPT

Dimension L

N/A 1-1/2 in NPT

Dimension M

N/A 41 in104 cm

Maximum Recovery

Recovery at 36 ºF Temperature Rise

N/A 849 gal/h

Recovery at 20 ºC Temperature Rise

N/A 3216 L/h

Recovery at 40 ºF Temperature Rise

N/A 765 gal/h

Recovery at 22 ºC Temperature Rise

N/A 2894 L/h

Recovery at 50 ºF Temperature Rise

N/A 612 gal/h

Recovery at 28 ºC Temperature Rise

N/A 2315 L/h

Recovery at 54 ºF Temperature Rise

N/A 566 gal/h

Recovery at 30 ºC Temperature Rise

N/A 2144 L/h

Recovery at 60 ºF Temperature Rise

N/A 510 gal/h

Recovery at 33 ºC Temperature Rise

N/A 1929 L/h

Recovery at 70 ºF Temperature Rise

N/A 437 gal/h

Recovery at 39 ºC Temperature Rise

N/A 1654 L/h

Recovery at 72 ºF Temperature Rise

N/A 425 gal/h

Recovery at 40 ºC Temperature Rise

N/A 1608 L/h

Recovery at 80 ºF Temperature Rise

N/A 382 gal/h

Recovery at 44 ºC Temperature Rise

N/A 1447 L/h

Recovery at 90 ºF Temperature Rise

N/A 340 gal/h

Recovery at 50 ºC Temperature Rise

N/A 1286 L/h

Recovery at 100 ºF Temperature Rise

N/A 306 gal/h

Recovery at 56 ºC Temperature Rise

N/A 1158 L/h

Recovery at 108 ºF Temperature Rise

N/A 283 gal/h

Recovery at 60 ºC Temperature Rise

N/A 1072 L/h

Recovery at 110 ºF Temperature Rise

N/A 278 gal/h

Recovery at 61 ºC Temperature Rise

N/A 1052 L/h

Recovery at 120 ºF Temperature Rise

N/A 255 gal/h

Recovery at 67 ºC Temperature Rise

N/A 965 L/h

Recovery at 126 ºF Temperature Rise

N/A 243 gal/h

Recovery at 70 ºC Temperature Rise

N/A 919 L/h

Recovery at 130 ºF Temperature Rise

N/A 235 gal/h

Recovery at 72 ºC Temperature Rise

N/A 890 L/h

Recovery at 140 ºF Temperature Rise

N/A 218 gal/h

Recovery at 78 ºC Temperature Rise

N/A 827 L/h

Electrical Characteristics

Voltage

N/A 120 V

Frequency

N/A 60 Hz

Current

N/A <5 A

Clearances to Combustibles

Sides and Rear Clearance to Combustibles

N/A 0 in

Top Cover Clearance to Combustibles

N/A 12 in

Sides and Rear Clearance to Non-Combustibles

N/A 0 in

Top Cover Clearance to Non-Combustibles

N/A 12 in

Water Connection

Top Inlet Water Connection

N/A 1-1/2 in

Front Inlet Water Connection

N/A 1-1/2 in

Back Inlet Water Connection

N/A 1-1/2 in

Top Outlet Water Connection

N/A 1-1/2 in

Front Outlet Water Connection

N/A 1-1/2 in

Back Outlet Water Connection

N/A 1-1/2 in

Features

Features

N/A 82% thermal efficiency means lower operating costs.

Fan Assisted Combustion
  • The blower is built into the Low NOx burner assembly for Ultra-Low NOx readings that comply with SCQAMD rule 1146.2 of 14 ng/j or 20 ppm.
Metal Venting
  • Rated Category I Appliance. Uses standard double wall type "B" vent.
  • Can be commonly vented with other Category I appliances.
  • Vent connects directly to the vent connector outlet.
  • No Draft hood or barometric damper required.
  • Perfect choice for retrofit and upgrade installations.
Water Connections
  • For ease of installation, all BCL3s feature water connections on the top, front, and rear.
  • Self Cleaning inlet water connection eliminates harmful scale buildup, extending the life of the product.
  • The front inlet connection must be used for the Self Cleaning benefits.
Glasslined Tank
  • Our proprietary slush coating is applied after the complete tank has been assembled to give a seamless barrier against hot water corrosion.
  • Maximum working pressure 160 psi.
Installed Cost Savings
  • When multiple BCL3 units are exclusively used in a vent manifold, use the National Fuel Gas Code Table 13 Vent Sizing information to determine vent diameter and specifications.
Fully Automatic Digital Control with Safety Shutoff
  • Accurate, dependable control system. Features a two speed blower control for smooth main burner light off.
  • Manual reset gas shutoff device for added safety.
  • Maximum inlet gas pressure is 14" W.C. Minimum gas pressure is 3.5" W.C. Natural Gas.
Foam Insulation
  • Saves fuel, helps reduce standby heat loss.
Jacket
  • Heavy gauge steel finished with a baked enamel finish over a bonderized undercoat.
Easy Cleaning
  • Handhole cleanout allows access for easy cleaning.
Fully Tested for Safety and Performance
  • Design certified by the Underwriters Laboratory for 180 ºF hot water service.
  • Meets rigid requirements of the National Sanitation Foundation when equipped with optional leg kit.
  • Certified for use on combustible flooring.
Intermittent Ignition Device.
  • Eliminates standing pilot.
  • Provides flame failure response in less than one second.
  • Spark ignitor and power ON/OFF switch.
Easy-To-Install
  • Completely factory-assembled.
  • Only gas, water, vent and electric connections need be made.
  • Provided with drain valve.
Anodes
  • Long-life, stainless steel core anode rods.
Plug Kits
  • Pipe nipples and caps are included to plug unused water connections.

Testing and Certifications

Testing and Certifications

N/A Approval Ratings and Certification
  • All models meet ANSI Z21.10.3 - CSA 4.3 standards and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1

Other Features

Other Features

N/A
  • Integral automatic gas shutoff system prevents excessive water temperature
  • CSA Certified and ASME Rated T&P Relief Valve are factory-installed
  • Maximum working pressure is 160 psi standard
  • Adjustable thermostat with a 120 to 180 ºF range
  • All models certified up to 7,700 ft

Warranty

Warranty

N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.

Note

Note

N/A Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

All models rated at 82% thermal efficiency.

Models available for sale in California only.