Catalog
		
            Designed for use as recovery heaters for light-duty hot water supply service. Patriot™ PCE water heaters are available with tank capacities from 6 through 119 gallons. They can be installed for non- simultaneous and single element operation (maximum input up to 6 kW), or for simultaneous dual-element operation (Maximum input up to 12 kW).
        
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Maximum Recovery
                            |
                        Dimensions
                            |
                        Testing and Certifications
                            |
                        Other Patriot™ PCE Series Features
                            |
                        Features
                            |
                        Warranty
                
            
            Specifications
                                                                                Manufacturer | 
                                                                        N/A State® | 
                                                                                Operation Type | 
                                                                        N/A Non-Simultaneous Operation | 
                                                                                Number of Elements | 
                                                                        N/A 2 | 
                                                                                Tank Capacity | 
                                                                        N/A 40 U.S. gal151 L | 
                                                                                Maximum Hydrostatic Working Pressure | 
                                                                        N/A 150 psi | 
                                                                                Element Type | 
                                                                        N/A Lower Upper | 
                                                                                Input Power | 
                                                                        N/A 3000 W | 
                                                                                Approximate Shipping Weight | 
                                                                        N/A 113 lb51.3 kg | 
                                                                                Voltage | 
                                                                        N/A 120 V208 V240 V277 V480 V | 
                                                                                Style | 
                                                                        N/A Patriot™ Series | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Type | 
                                                                        N/A Electric | 
                                                                                Industry Standards | 
                                                                        N/A CSA® Certified UL® Listed | 
Maximum Recovery
                                                                                Recovery at 36 ºF Temperature Rise | 
                                                                        N/A 34 U.S. gal/h | 
                                                                                Recovery at 20 ºC Temperature Rise | 
                                                                        N/A 128 L/h | 
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 30 U.S. gal/h | 
                                                                                Recovery at 22.2 ºC Temperature Rise | 
                                                                        N/A 115 L/h | 
                                                                                Recovery at 54 ºF Temperature Rise | 
                                                                        N/A 23 U.S. gal/h | 
                                                                                Recovery at 30 ºC Temperature Rise | 
                                                                        N/A 85 L/h | 
                                                                                Recovery at 60 ºF Temperature Rise | 
                                                                        N/A 20 U.S. gal/h | 
                                                                                Recovery at 33.3 ºC Temperature Rise | 
                                                                        N/A 77 L/h | 
                                                                                Recovery at 72 ºF Temperature Rise | 
                                                                        N/A 17 U.S. gal/h | 
                                                                                Recovery at 40 ºC Temperature Rise | 
                                                                        N/A 64 L/h | 
                                                                                Recovery at 80 ºF Temperature Rise | 
                                                                        N/A 15 U.S. gal/h | 
                                                                                Recovery at 44.4 ºC Temperature Rise | 
                                                                        N/A 58 L/h | 
                                                                                Recovery at 90 ºF Temperature Rise | 
                                                                        N/A 14 U.S. gal/h | 
                                                                                Recovery at 50 ºC Temperature Rise | 
                                                                        N/A 51 L/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 12 U.S. gal/h | 
                                                                                Recovery at 55.5 ºC Temperature Rise | 
                                                                        N/A 46 L/h | 
                                                                                Recovery at 108 ºF Temperature Rise | 
                                                                        N/A 11 U.S. gal/h | 
                                                                                Recovery at 60 ºC Temperature Rise | 
                                                                        N/A 43 L/h | 
                                                                                Recovery at 120 ºF Temperature Rise | 
                                                                        N/A 10 U.S. gal/h | 
                                                                                Recovery at 66.6 ºC Temperature Rise | 
                                                                        N/A 38 L/h | 
                                                                                Recovery at 126 ºF Temperature Rise | 
                                                                        N/A 10 U.S. gal/h | 
                                                                                Recovery at 70 ºC Temperature Rise | 
                                                                        N/A 37 L/h | 
Dimensions
                                                                                Dimension A | 
                                                                        N/A 45-1/8 in1146 mm | 
                                                                                Dimension B | 
                                                                        N/A 20-1/2 in521 mm | 
                                                                                Dimension D | 
                                                                        N/A 8 in203 mm | 
Testing and Certifications
                                                                                Testing and Certifications | 
                                                                        N/A Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 | 
Other Patriot™ PCE Series Features
                                                                                Other Patriot™ PCE Series Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Features
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          Zinc-Plated Copper Sheath Heating Elements Standards
 
 
 
 
  | 
                                                    