Catalog
		
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Dimensions
                            |
                        Maximum Recovery (ºF)
                            |
                        Maximum Recovery (ºC)
                            |
                        Electrical Characteristics
                            |
                        Features
                            |
                        Options
                            |
                        Testing and Certifications
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
| Manufacturer | N/A A. O. Smith® | 
| Capacity | N/A 98 gal | 
| Type | N/A Liquid Propane Gas Natural Gas | 
| Input Power | N/A 90000 BTU/hr26.4 kW | 
| Manifold Pressure | N/A For Liquid Propane Gas: 2.49 kPaFor Natural Gas: 1.12 kPaFor Liquid Propane Gas: 10 inWcFor Natural Gas: 4.5 inWc | 
| Maximum Gas Supply Pressure | N/A 14 inWc3.48 kPa | 
| Minimum Supply Pressure for Natural Gas | N/A 1.24 kPa5 in | 
| Minimum Supply Pressure for Liquid Propane Gas | N/A 11 inWc2.74 kPa | 
| Industry Standards | N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 | 
Dimensions
Maximum Recovery (ºF)
| Recovery at 30 ºF Temperature Rise | N/A 291 gal/h | 
| Recovery at 36 ºF Temperature Rise | N/A 242 gal/h | 
| Recovery at 40 ºF Degree Rise | N/A 218 gal/h | 
| Recovery at 50 ºF Temperature Rise | N/A 175 gal/h | 
| Recovery at 54 ºF Temperature Rise | N/A 162 gal/h | 
| Recovery at 60 ºF Temperature Rise | N/A 145 gal/h | 
| Recovery at 70 ºF Temperature Rise | N/A 125 gal/h | 
| Recovery at 72 ºF Temperature Rise | N/A 121 gal/h | 
| Recovery at 80 ºF Temperature Rise | N/A 109 gal/h | 
| Recovery at 90 ºF Temperature Rise | N/A 97 gal/h | 
| Recovery at 100 ºF Temperature Rise | N/A 87 gal/h | 
| Recovery at 108 ºF Temperature Rise | N/A 81 gal/h | 
| Recovery at 110 ºF Temperature Rise | N/A 79 gal/h | 
| Recovery at 120 ºF Temperature Rise | N/A 73 gal/h | 
| Recovery at 126 ºF Temperature Rise | N/A 69 gal/h | 
| Recovery at 130 ºF Temperature Rise | N/A 67 gal/h | 
| Recovery at 140 ºF Temperature Rise | N/A 62 gal/h | 
Maximum Recovery (ºC)
| Recovery at 17 ºC Temperature Rise | N/A 1104 L/h | 
| Recovery at 20 ºC Temperature Rise | N/A 915 L/h | 
| Recovery at 23 ºC Temperature Rise | N/A 825 L/h | 
| Recovery at 28 ºC Temperature Rise | N/A 662 L/h | 
| Recovery at 30 ºC Temperature Rise | N/A 613 L/h | 
| Recovery at 33 ºC Temperature Rise | N/A 548 L/h | 
| Recovery at 39 ºC Temperature Rise | N/A 473 L/h | 
| Recovery at 40 ºC Temperature Rise | N/A 457 L/h | 
| Recovery at 44 ºC Temperature Rise | N/A 412 L/h | 
| Recovery at 50 ºC Temperature Rise | N/A 367 L/h | 
| Recovery at 56 ºC Temperature Rise | N/A 329 L/h | 
| Recovery at 60 ºC Temperature Rise | N/A 306 L/h | 
| Recovery at 61 ºC Temperature Rise | N/A 299 L/h | 
| Recovery at 67 ºC Temperature Rise | N/A 276 L/h | 
| Recovery at 70 ºC Temperature Rise | N/A 261 L/h | 
| Recovery at 72 ºC Temperature Rise | N/A 253 L/h | 
| Recovery at 78 ºC Temperature Rise | N/A 234 L/h | 
Features
| Features | N/A
                                                                                          The BTN-80 and BTN-100 are equipped with a factory-mounted blower that is pre-wired. This blower produces a pre-ignition draft of make-up air prior to burner ignition and provides more efficient control of heat and helps ensure an adequate supply of make-up air. Prior to ignition, the control proves a working draft. Factory-installed Blower 
 
 
 
 Glass Lined Tank 
 
 Optional Leg Kit To Meet Nsf Standard 5 (Part # 9006645005 BTN 80 & 100) Intelli-Vent™ is a registered trademark of Emerson Electric Company. | 
Options
| Options | N/A
                                                                                          Conservationist® Btn Options Optional Leg Kit to Meet NSF Standard 5 (Part # 9006645005 BTN 80 & 100) Intelli-Vent™ is a registered trademark of Emerson Electric Company. | 
Testing and Certifications
| Testing and Certifications | N/A
                                                                                          CSA® Certified and ASME Rated T&P Relief Valve Codes and Standards 
 | 