            Specifications
| Manufacturer | N/A A. O. Smith® | 
| Equipment Grade | N/A Commercial | 
| Input Power | N/A 199000 KBTU/hr58 kW | 
| Capacity | N/A 93 U.S. gal352 L | 
| Thermal Efficiency | N/A 82 % | 
| Type | N/A Natural Gas | 
| Minimum Gas Supply Pressure | N/A 0.87 kPa15 inWc | 
| Maximum Gas Supply Pressure | N/A 14 inWc3.48 kPa | 
| Sides and Rear Clearance to Combustibles | N/A 0 in | 
| Top Cover Clearance to Combustibles | N/A 12 in | 
| Sides and Rear Clearance to Non-Combustibles | N/A 0 in | 
| Top Cover Clearance to Non-Combustibles | N/A 12 in | 
| Top Inlet Water Connection | N/A 1-1/2 in | 
| Front Inlet Water Connection | N/A 1-1/2 in | 
| Back Inlet Water Connection | N/A 1-1/2 in | 
| Top Outlet Water Connection | N/A 1-1/2 in | 
| Front Outlet Water Connection | N/A 1-1/2 in | 
| Back Outlet Water Connection | N/A 1-1/2 in | 
| Standard Approximate Shipping Weight | N/A 835 lb379 kg | 
| Industry Standards | N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 ASME Certified | 
Dimensions
Maximum Recovery (ºF)
| Recovery at 36 ºF Temperature Rise | N/A 549 gal/h | 
| Recovery at 40 ºF Temperature Rise | N/A 494 gal/h1040 L/h | 
| Recovery at 50 ºF Temperature Rise | N/A 396 gal/h | 
| Recovery at 54 ºF Temperature Rise | N/A 366 gal/h | 
| Recovery at 60 ºF Temperature Rise | N/A 330 gal/h | 
| Recovery at 70 ºF Temperature Rise | N/A 283 gal/h | 
| Recovery at 72 ºF Temperature Rise | N/A 275 gal/h | 
| Recovery at 90 ºF Temperature Rise | N/A 247 gal/h | 
| Recovery at 100 ºF Temperature Rise | N/A 198 gal/h | 
| Recovery at 108 ºF Temperature Rise | N/A 183 gal/h | 
| Recovery at 110 ºF Temperature Rise | N/A 180 gal/h | 
| Recovery at 120 ºF Temperature Rise | N/A 165 gal/h | 
| Recovery at 126 ºF Temperature Rise | N/A 157 gal/h | 
| Recovery at 130 ºF Temperature Rise | N/A 152 gal/h | 
| Recovery at 140 ºF Temperature Rise | N/A 141 gal/h | 
Maximum Recovery (ºC)
| Recovery at 20 ºC Temperature Rise | N/A 2080 L/h | 
| Recovery at 22 ºC Temperature Rise | N/A 1872 L/h | 
| Recovery at 28 ºC Temperature Rise | N/A 1497 L/h | 
| Recovery at 30 ºC Temperature Rise | N/A 1386 L/h | 
| Recovery at 33 ºC Temperature Rise | N/A 1248 L/h | 
| Recovery at 39 ºC Temperature Rise | N/A 1070 L/h | 
| Recovery at 50 ºC Temperature Rise | N/A 832 L/h | 
| Recovery at 56 ºC Temperature Rise | N/A 749 L/h | 
| Recovery at 60 ºC Temperature Rise | N/A 693 L/h | 
| Recovery at 61 ºC Temperature Rise | N/A 681 L/h | 
| Recovery at 67 ºC Temperature Rise | N/A 624 L/h | 
| Recovery at 70 ºC Temperature Rise | N/A 594 L/h | 
| Recovery at 72 ºC Temperature Rise | N/A 576 L/h | 
| Recovery at 78 ºC Temperature Rise | N/A 535 L/h | 
Features
| Features | N/A
                                                                                          82% thermal efficiency means lower operating costs. Fan Assisted Combustion - The blower is built into the Low NOx burner assembly for Ultra-Low NOx readings that comply with SCQAMD rule1146.2 of 14 ng/j or 20 ppm. Metal Venting - Rated Category I Appliance. Uses standard double wall type "B" vent. Can be commonly vented with other Category I appliances. Vent connects directly to the vent connector outlet. No Draft hood or barometric damper required. Perfect choice for retrofit and upgrade installations. Water Connections - For ease of installation, all BTLs feature water connections on the top, front, and rear. "The Eliminator™" inlet water connection eliminates harmful scale buildup, extending the life of the product. The front inlet connection must be used for the Eliminator™ benefits. Glass Lined Tank - Permaglas® Ultracoat is the proprietary ceramic coating developed by A. O. Smith®’s ceramic engineers specifically for the heater. It is applied after the complete tank has been assembled to give a seamless barrier against hot water corrosion. Installed Cost Savings - When multiple BTL units are exclusively used in a vent manifold, use the National Fuel Gas Code Table 13 Vent Sizing information to determine vent diameter and specifications. The BTL often uses a smaller vent diameter than a natural draft water heater which saves on installation cost. Fully Automatic Digital Controls with Safety Shutoff - Accurate, dependable control system. Features a two speed blower control for smooth main burner light-off. Manual reset gas shutoff device for added safety. Maximum inlet gas pressure is 14" W.C. Minimum gas pressure is 3.5" W.C. Natural Gas. Foam Insulation - Saves fuel, helps reduce standby heat loss. Jacket - Heavy gauge steel finished with a baked enamel finish over a bonderized undercoat. Easy Cleaning - Handhole cleanout allows access for easy cleaning. Intermittent Ignition Device - Eliminates standing pilot. Provides flame failure response in less than one second. Spark igniter and power ON/OFF switch. Easy-to-install - Completely factory-assembled. Only gas, water, vent and electric connections need be made. Provided with drain valve. Anodes - CoreGuard™ long-life, stainless steel core anode rods. Plug Kits - Pipe nipples and caps are included to plug unused water connections. | 
Other Standard Features
| Other Standard Features | N/A 
 | 
Testing and Certifications
| Testing and Certifications | N/A
                                                                                          Fully Tested for Safety and Performance - Design certified by the Underwriters Laboratory for 180°F hot water service. Meets rigid requirements of the National Sanitation Foundation when equipped with optional leg kit. Certified for use on combustible flooring. Approval Ratings and Certification - All models meet ANSI Z21.10.3 - CSA® 4.3 standards and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. NSF LEG Kit 
 | 