Catalog
		
                    Unit of Measure
                    
               
        
            Specifications
| Manufacturer | N/A Bradford White® | 
| Capacity | N/A 100 U.S. gal83 Imp. gal379 L | 
| Input Power | N/A 270000 BTU/hr79.1 kW | 
| Water Connection Diameter | N/A 1-1/2 in38 mm | 
| Gas Connection Diameter | N/A 3/4 in19 mm | 
| Relief Valve Opening | N/A 1 in25 mm | 
| Approximate Shipping Weight | N/A 700 lb318 kg | 
| Current | N/A 1.0 to 2.6 A | 
| Test Pressure | N/A 300 psi2068 kPa | 
| Working Pressure | N/A 150 psi1034 kPa | 
| Thermal Efficiency | N/A 84 % | 
| Style | N/A ULN Atmospheric Vent | 
| Size | N/A C | 
| Type | N/A Natural Gas | 
| Industry Standards | N/A AHRI Certified® ANSI Standards Z-21.10.3 ASHRAE 90.1b (Current Standards) ASME Certified C.E.C. Listed CSA® Certified NSF | 
Maximum Recovery
| Recovery at 40 ºF Temperature Rise | N/A 687 gal/h | 
| Recovery at 22 ºC Temperature Rise | N/A 2601 L/h | 
| Recovery at 100 ºF Temperature Rise | N/A 275 gal/h | 
| Recovery at 56 ºC Temperature Rise | N/A 1041 L/h | 
| Recovery at 140 ºF Temperature Rise | N/A 196 gal/h | 
| Recovery at 78 ºC Temperature Rise | N/A 742 L/h | 
Dimensions
General Information
| General Information | N/A All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), to ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it can supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). | 
Features
| Features | N/A
                                                                                          The Ultra-Low NOx Models feature: 
 | 
Note
| Note | N/A
                                                                                          Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed. Complies with the latest Ultra-Low NOx requirements - 14 ng/joule or less. Gas Pressure: 14.0" w.c. maximum static, 4.5" w.c. minimum running (Recommend 7.0" w.c. minimum running). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. | 