Catalog
		
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        3" Vent Pipe
                            |
                        4" Vent Pipe
                            |
                        Maximum Recovery
                            |
                        Dimensions
                            |
                        General Information
                            |
                        Optional Equipment Features
                            |
                        Additional Equipment Features
                            |
                        Features
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
| Manufacturer | N/A Bradford White® | 
| Standard Type | N/A Non-ASME | 
| Capacity | N/A 100 U.S. gal83 Imp. gal379 L | 
| Input Power | N/A 250000 BTU/hr73.2 kW·h | 
| First Hour Delivery at 100 ºF Temperature Rise | N/A 364 gal | 
| Water Connection Diameter | N/A 1-1/2 in38 mm | 
| Gas Connection Diameter | N/A 3/4 in19 mm | 
| Relief Valve Opening | N/A 1 in25 mm | 
| Approximate Shipping Weight | N/A 900 lb408 kg | 
| Type | N/A Natural Gas | 
| Style | N/A Ultra-High Efficiency | 
| Size | N/A C | 
| Test Pressure | N/A 300 psi2068 kPa | 
| Working Pressure | N/A 150 psi1034 kPa | 
| Industry Standards | N/A AHRI Certified® ASME Certified CSA® Certified NSF | 
3" Vent Pipe
| Maximum Intake Length for 3" Vent Pipe (Power Direct Vent) | N/A 40 ft | 
| Maximum Exhaust Length for 3" Vent Pipe (Power Direct Vent) | N/A 40 ft | 
| Maximum Exhaust Length for 3" Vent Pipe (Power Vent) | N/A 80 ft | 
4" Vent Pipe
| Maximum Intake Length for 4" Vent Pipe (Power Direct Vent) | N/A 65 ft | 
| Maximum Exhaust Length for 4" Vent Pipe (Power Direct Vent) | N/A 65 ft | 
| Maximum Exhaust Length for 4" Vent Pipe (Power Vent) | N/A 130 ft | 
Maximum Recovery
| Recovery at 40 ºF Degree Rise | N/A 735 gal/h | 
| Recovery at 22 ºC Degree Rise | N/A 2782 L/h | 
| Recovery at 100 ºF Degree Rise | N/A 294 gal/h | 
| Recovery at 56 ºC Degree Rise | N/A 1113 L/h | 
| Recovery at 140 ºF Degree Rise | N/A 210 gal/h | 
| Recovery at 78 ºC Degree Rise | N/A 795 L/h | 
| Thermal Efficiency | N/A 97 % | 
Dimensions
General Information
| General Information | N/A
                                                                                          All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. | 
Optional Equipment Features
| Optional Equipment Features | N/A
                                                                                          Maxitrol Gas Pressure Regulating valve - Ensures proper supply pressure to eF unit of 7" to 11" W.C. (provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. NSF Compliance Kit - p/n 265-44542-04. Low Gas Inlet Pressure Option - Pre-assembled to allow operation at lower inlet natural gas pressure (Down to 3.5" w.c.). | 
Additional Equipment Features
| Additional Equipment Features | N/A 
 | 
Features
| Features | N/A 
 | 
Note
| Note | N/A
                                                                                          Air intake cannot exceed exhaust by more than 30 ft. in any venting situation. Subtract 5 ft. for each additional 90º elbow. All models comply with the latest ultra-low NOx requirements of 14 ng/J or less. Amp Draw range = 1.0 to 1.8 amps. 14.0" w.c. maximum static, 4.5" w.c. minimum running (Recommend 7.0" w.c. minimum running) Concentric Vent Kit Termination - 3" termination fitting provides for only one exit opening through wall or roof (p/n 239-44069-01). Diagrams are for both 60 and 100 gallon models. | 