Catalog
The Polaris® has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service no anode required. A submerged combustion chamber with spiral flue provides up to 96% thermal efficiency and ultra-low standby heat loss of approximately 1%.
Unit of Measure
Specifications
|
Dimensions
|
Maximum Recovery
|
First Hour Rating Available
|
Maximum First Hour Recovery and Storage
|
Maximum Recovery (Continuous Operation)
|
General Information
|
Woven Metal Burner
|
Whisper Quiet Blower
|
Easy to Install and Service
|
Features
|
Other Features
|
Warranty
|
Note
Specifications
Manufacturer |
N/A American® Water Heater Company |
Capacity |
N/A 34 gal |
Input Power |
N/A 130000 BTU/hr |
Thermal Efficiency |
N/A 96 % |
Approximate Shipping Weight |
N/A 150 lb |
Tank |
N/A Stainless Steel |
Diameter |
N/A 22 in |
Minimum Approximate Installed Height |
N/A 67 in |
Side Wall Vent Option |
N/A Standard |
Vent Type |
N/A ABS CPVC Plastic PVC |
Sealed Combustion |
N/A Yes |
Self-Diagnostic Control |
N/A Yes |
Resists Negative Building Pressure |
N/A Yes |
Maximum Temperature Setting |
N/A 185 ºF |
Insulation Thickness |
N/A 2 in |
Low NOx |
N/A Standard |
Style |
N/A Polaris® High Efficiency |
Size |
N/A C |
Type |
N/A Natural Gas |
Industry Standards |
N/A ANSI Standards Z-21.10.3 ASHRAE Standards CSA® 4.3 IESNA 90.1 |
Dimensions
Maximum Recovery
Recovery at 40 ºF Temperature Rise |
N/A 378 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 303 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 252 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 216 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 189 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 168 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 152 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 126 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 116 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 106 gal/h |
First Hour Rating Available
First Hour Rating at 40 ºF Temperature Rise |
N/A 405 gal |
First Hour Rating at 50 ºF Temperature Rise |
N/A 330 gal |
First Hour Rating at 60 ºF Temperature Rise |
N/A 279 gal |
First Hour Rating at 70 ºF Temperature Rise |
N/A 243 gal |
First Hour Rating at 80 ºF Temperature Rise |
N/A 216 gal |
First Hour Rating at 90 ºF Temperature Rise |
N/A 195 gal |
First Hour Rating at 100 ºF Temperature Rise |
N/A 179 gal |
First Hour Rating at 110 ºF Temperature Rise |
N/A 165 gal |
First Hour Rating at 120 ºF Temperature Rise |
N/A 153 gal |
First Hour Rating at 130 ºF Temperature Rise |
N/A 143 gal |
First Hour Rating at 140 ºF Temperature Rise |
N/A 135 gal |
Maximum First Hour Recovery and Storage
Maximum First Hour Recovery and Storage at 40 ºF Temperature Rise |
N/A 6.8 gal/h |
Maximum First Hour Recovery and Storage at 50 ºF Temperature Rise |
N/A 5.5 gal/h |
Maximum First Hour Recovery and Storage at 60 ºF Temperature Rise |
N/A 4.7 gal/h |
Maximum First Hour Recovery and Storage at 70 ºF Temperature Rise |
N/A 4.1 gal/h |
Maximum First Hour Recovery and Storage at 80 ºF Temperature Rise |
N/A 3.6 gal/h |
Maximum First Hour Recovery and Storage at 90 ºF Temperature Rise |
N/A 3.3 gal/h |
Maximum First Hour Recovery and Storage at 100 ºF Temperature Rise |
N/A 3 gal/h |
Maximum First Hour Recovery and Storage at 110 ºF Temperature Rise |
N/A 2.8 gal/h |
Maximum First Hour Recovery and Storage at 120 ºF Temperature Rise |
N/A 2.6 gal/h |
Maximum First Hour Recovery and Storage at 130 ºF Temperature Rise |
N/A 2.4 gal/h |
Maximum First Hour Recovery and Storage at 140 ºF Temperature Rise |
N/A 2.3 gal/h |
Maximum Recovery (Continuous Operation)
Maximum Recovery at 40 ºF Temperature Rise (Continuous Operation) |
N/A 6.3 gpm |
Maximum Recovery at 50 ºF Temperature Rise (Continuous Operation) |
N/A 5.1 gpm |
Maximum Recovery at 60 ºF Temperature Rise (Continuous Operation) |
N/A 4.2 gpm |
Maximum Recovery at 70 ºF Temperature Rise (Continuous Operation) |
N/A 3.6 gpm |
Maximum Recovery at 80 ºF Temperature Rise (Continuous Operation) |
N/A 3.2 gpm |
Maximum Recovery at 90 ºF Temperature Rise (Continuous Operation) |
N/A 2.8 gpm |
Maximum Recovery at 100 ºF Temperature Rise (Continuous Operation) |
N/A 2.5 gpm |
Maximum Recovery at 110 ºF Temperature Rise (Continuous Operation) |
N/A 2.3 gpm |
Maximum Recovery at 120 ºF Temperature Rise (Continuous Operation) |
N/A 2.1 gpm |
Maximum Recovery at 130 ºF Temperature Rise (Continuous Operation) |
N/A 1.9 gpm |
Maximum Recovery at 140 ºF Temperature Rise (Continuous Operation) |
N/A 1.8 gpm |
General Information
General Information |
N/A
Up to 96% Efficient
An ultra quiet radial blower is combined with a submerged burner for whisper quiet operation. Indicator lights illuminate when the power is on and when the igniter and burner are operating. |
Woven Metal Burner
Woven Metal Burner |
N/A
|
Whisper Quiet Blower
Whisper Quiet Blower |
N/A A high capacity, quiet, brushless, DC motor is combined with an integrated gas/air control safety system resulting in excellent combustion with flexible venting options. |
Easy to Install and Service
Easy to Install and Service |
N/A
|
Features
Features |
N/A
|
Other Features
Other Features |
N/A
|
Note
Note |
N/A
This water heater design has been tested by CSA International and complies with ANSI Z21.10.1, Section 2.35 Flammable Vapor Resistance 3" Concentric Vent Part «6911089 of 2" Concentric Vent Part »6911088. Specification are subject to change without notice In accordance with our policy of continuous improvement. Input output and recovery may vary depending upon air inlet and exhaust outlet Installations. Length and number of bends In Inlet and outlet pipes may reduce Input and output.1/2" gas supply line can be used for up to 150,000 BTU units; units over 150,000 BTU's require a 3/4" gas supply line. All installations are one or two temperature, with or without recirculation. |