Catalog
All commercial electric units have a Fused Ceramic Shield applied under pressure and fired at 1600 ºF to completely cover the tank interior. This provides a tough interior surface for storage tanks and maximum protection against the wearing effects of high-volume and high-temperature water.
Unit of Measure

Specifications

Manufacturer

American® Water Heater Company

Capacity

30 gal

Standard Voltage

240 V

Standard Input Power

4.5 kW

Maximum Input Power

12 kW

Element Power

5000 W

Operation Type

Interlocking Operation Simultaneous Operation

Voltage

208 V240 V277 V480 V

Phase

Single Three

Water Connection

3/4 in

Style

Standard

Size

C

Type

Electric

Industry Standards

ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed

Dimensions

Schematic


Schematic Drawing for Commercial Electric Water Heaters

Jacket Diameter A

18 in

Height to Top of Heater B

45-1/4 in

Height to Side T and P Opening C

38-1/2 in

Maximum Recovery

Recovery at 40 ºF Temperature Rise

51 gal/h

Recovery at 50 ºF Temperature Rise

41 gal/h

Recovery at 60 ºF Temperature Rise

34 gal/h

Recovery at 70 ºF Temperature Rise

29 gal/h

Recovery at 80 ºF Temperature Rise

26 gal/h

Recovery at 90 ºF Temperature Rise

23 gal/h

Recovery at 100 ºF Temperature Rise

20 gal/h

Electrical Characteristics

Full Load Current Single Phase 208 V

24.0 A

Full Load Current Single Phase 240 V

20.8 A

Full Load Current Single Phase 277 V

18.1 A

Full Load Current Single Phase 480 V

10.4 A

Full Load Current Three Phase 208 V (All Terminals L1, L2, and L3)

24 A

Full Load Current Three Phase 240 V (All Terminals L1, L2, and L3)

20.8 A

Full Load Current Three Phase 480 V (All Terminals L1, L2, and L3)

10.4 A

Full Load Current Three Phase 208 V (Terminal L3)

41.6 A

Full Load Current Three Phase 240 V (Terminal L3)

36.1 A

Full Load Current Three Phase 480 V (Terminal L3)

18 A

Full Load Current Three Phase 208 V (Terminal L1 and L2)

24 A

Full Load Current Three Phase 240 V (Terminal L1 and L2)

20.8 A

Full Load Current Three Phase 480 V (Terminal L1 and L2)

10.4 A

Features

Features

  • "Environmentally-Friendly" Non-CFC Insulation.
    Foam insulation traps heat within the tank, saving energy.
  • Combination Surface-Mounted Thermostats with High Limits.
    Adjustable to 170 ºF. One thermostat provided for each element. High limit factory set at 190 ºF.
  • Anode Rod.
    Promotes longer tank life through protection against corrosion of tank interior.
  • Incoloy Screw-In Elements.
    For ease of service and long life.
  • Wattages from 3 kW to 12 kW.
  • 208, 240, 277, 480 Voltages Available.
  • UL® Listed.
  • Non-Metallic, Corrosion-free Durable, Brass Drain Valve.
  • Interlocking or Simultaneous Element Wiring.
  • Single-Phase or Unbalanced Three-Phase Operation Available (277 volt, single phase only).
  • Dip Tube
    Carries cold inlet water deep into the tank to minimize temperature dilution of hot water.
  • 3/4" Water Connections
    Located on top.

Warranty

Warranty

  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.

Note

Note

Limited warranty on tank and parts. Complete details in manual. Specify wattage, voltage and phase when ordering.