Catalog
Compact commercial electric units have a Fused Ceramic Shield applied under pressure and fired at 1600 ºF to completely cover the tank interior. This provides a tough interior surface for storage tanks and maximum protection against the wearing effects of high-volume and high temperature water.
Unit of Measure

Specifications

Manufacturer

American® Water Heater Company

Capacity

12 gal

Standard Voltage

120 V

Standard Input Power

1.5 kW

Maximum Input Power

5.5 kW

Element Power

6000 W

Full Load Current Single Phase 240 V

25 A

Full Load Current Single Phase 277 V

21.7 A

Full Load Current Single Phase 480 V

12.5 A

Voltage

240 V277 V480 V

Phase

Single

Water Connection

3/4 in

Test Pressure

300 psi

Working Pressure

150 psi

Style

Utility

Size

C

Type

Electric

Industry Standards

UL® 174

Dimensions

Schematic


Schematic Drawing for Compact Commercial Electric Water Heaters

Jacket Diameter A

16 in

Height to Top of Heater B

22-3/4 in

Height to Side T and P Opening C

16-1/2 in

Maximum Recovery

Recovery at 40 ºF Temperature Rise

61.4 gal/h

Recovery at 50 ºF Temperature Rise

49.2 gal/h

Recovery at 60 ºF Temperature Rise

41 gal/h

Recovery at 70 ºF Temperature Rise

35.1 gal/h

Recovery at 80 ºF Temperature Rise

30.7 gal/h

Recovery at 90 ºF Temperature Rise

27.3 gal/h

Recovery at 100 ºF Temperature Rise

24.6 gal/h

Features

Features

  • Foam Insulation
    The tank is surrounded by a thick coat of polyurethane foam to trap heat inside the tank, saving energy.
  • Heating Element
    Screw-in, direct immersion, 1500 watt, 120 volt heating element for maximum efficiency. Available in other wattages and voltages for every job.
  • Dip Tube
    Carries cold inlet water deep into the tank to minimize temperature dilution of hot water.
  • T & P Valve
    Conveniently located on the side of the tank to facilitate piping to a drain or external to the building.
  • 3/4" Water Connections
    Located on top. Optional side connections.
  • Anode Rod
    Top-mounted, heavy-duty anode for added tank protection, extending the life of the tank.
  • Built-In Electric Junction Box
    Top-located, convenient junction box, ready for 1/2" conduit.
  • Thermostat/High Limit Control
    Single-element thermostat adjustable to 170 ºF with high limit for single-element heaters.
  • Code Approvals
    Listed to UL 174. All models are certified at 300 PSI test pressure and 150 PSI working pressure.
  • Drain Valve
    Child-resistant, corrosion-free drain valve.

Warranty

Warranty

  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.

Note

Note

Limited warranty on tank and parts. Complete details in manual. Specify wattage, voltage and phase when ordering.