Catalog
Unit of Measure
Specifications
|
Maximum Recovery
|
Dimensions
|
Electrical Characteristics
|
3" Vent Pipe
|
4" Vent Pipe
|
Features
|
General Information
|
Warranty
|
Note
Specifications
Manufacturer |
N/A Bradford White® |
Capacity |
N/A 75 U.S. gal62 Imp. gal284 L |
Input Power |
N/A 55000 BTU/hr16.2 kW |
First Hour Rating1 | N/A 122 gal462 L |
Approximate Shipping Weight |
N/A 375 lb170 kg |
Test Pressure |
N/A 300 psi2068 kPa |
Working Pressure |
N/A 150 psi1034 kPa |
Gas Connection |
N/A 1/2 in13 mm |
Style |
N/A ULN Power Direct Vent |
Type |
N/A Natural Gas |
Size |
N/A C |
Industry Standards |
N/A AHRI Certified® ANSI CSA® Certified |
Maximum Recovery
Recovery at 100 ºF Temperature Rise2 | N/A 53 U.S. gal/h44 Imp. gal/h |
Recovery at 56 ºC Temperature Rise3 | N/A 201 L/h |
Dimensions
3" Vent Pipe
Maximum Intake Length for 3" Vent Pipe |
N/A 50 ft |
Maximum Exhaust Length for 3" Vent Pipe |
N/A 50 ft |
Minimum Vent Length for 3" Vent Pipe |
N/A 7 ft |
One 90º Elbows for 3" Vent Pipe |
N/A 45 ft |
Two 90º Elbows for 3" Vent Pipe |
N/A 40 ft |
Three 90º Elbows for 3" Vent Pipe |
N/A 35 ft |
4" Vent Pipe
Maximum Intake Length for 4" Vent Pipe |
N/A 90 ft |
Maximum Exhaust Length for 4" Vent Pipe |
N/A 90 ft |
Minimum Vent Length for 4" Vent Pipe |
N/A 7 ft |
One 90º Elbows for 4" Vent Pipe |
N/A 85 ft |
Two 90º Elbows for 4" Vent Pipe |
N/A 80 ft |
Three 90º Elbows for 4" Vent Pipe |
N/A 75 ft |
Features
Features |
N/A
The Light Duty UPDX Eco-Defender Safety System Models Feature:
|
General Information
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All water connections are 3/4" NPT (19 mm) on 11" (203 mm) centers. All gas connections are 1/2" (13 mm). All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. |
- 1 First Hour Rating is based on the latest AHRI Directory Listings.
- 2 Based on manufacturers rated recovery efficiency.
- 3 Based on manufacturers rated recovery efficiency.