Catalog
Universal™ is a family of commercial gas water heaters that are designed to fit into tight retrofit applications.
Unit of Measure
Specifications
|
Maximum Recovery
|
Maximum Delivery
|
Dimensions
|
Water Connection
|
Clearances to Combustibles
|
Features and Benefits
|
General Information
|
Warranty
|
Note
Specifications
Manufacturer |
N/A Rheem® |
Capacity |
N/A 35 to 100 gal |
Thermal Efficiency |
N/A 80 % |
Input Power |
N/A 250000 BTU/hr |
Tank Capacity |
N/A 100 gal379 L |
Temperature Rise |
N/A 100 ºF56 ºC |
Minimum to Recovery Contents |
N/A 25 |
Standard Approximate Shipping Weight |
N/A 795 lb360 kg |
ASME Approximate Shipping Weight |
N/A 835 lb378 kg |
Style |
N/A Universal™ |
Size |
N/A C |
Type |
N/A Liquid Propane Gas Natural Gas |
Industry Standards |
N/A ANSI ASME Certified C.E.C. Listed CSA® Certified |
Maximum Recovery
Recovery at 40 ºF Temperature Rise |
N/A 606 U.S. gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 2294 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 485 U.S. gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 1835 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 404 U.S. gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 1529 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 346 U.S. gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 1311 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 303 U.S. gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 1147 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 269 U.S. gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 1020 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 242 U.S. gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 918 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 220 U.S. gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 834 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 202 U.S. gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 765 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 186 U.S. gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 706 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 173 U.S. gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 655 L/h |
Maximum Delivery
Maximum Delivery (5 Minutes) |
N/A 90 U.S. gal341 L |
Maximum Delivery (10 Minutes) |
N/A 110 U.S. gal418 L |
Maximum Delivery (15 Minutes) |
N/A 131 U.S. gal494 L |
Maximum Delivery (20 Minutes) |
N/A 151 U.S. gal571 L |
Maximum Delivery (30 Minutes) |
N/A 191 U.S. gal724 L |
Maximum Delivery (45 Minutes) |
N/A 252 U.S. gal953 L |
Maximum Delivery (60 Minutes) |
N/A 312 U.S. gal1183 L |
Maximum Delivery (120 Minutes) |
N/A 555 U.S. gal2100 L |
Maximum Delivery (180 Minutes) |
N/A 797 U.S. gal3018 L |
Dimensions
Water Connection
Top Inlet/Outlet Water Connection |
N/A 1-1/2 in38 mm |
Front Side Water Connection |
N/A 2 in51 mm |
Rear Side Water Connection |
N/A 2 in51 mm |
Features and Benefits
Features and Benefits |
N/A
The tighter the commercial retrofit, the more you will appreciate how the Universal™’s compact size and multiple water connections simplify installations. Choose from 80% thermal efficiency models that range from 98,000-399,900 Btu/h and have maximum temperature setting of 180 degrees Fahrenheit. Space Saver Design The short heights and narrow jacket diameters, plus the top, front and rear water inlets/outlets offer the ultimate in installation flexibility. System Sentinel ™ LED Diagnostic System Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence. Patented Technology Universal’s proprietary steel formulation, patented multi-flue design, combined with two coats of porcelain enamel, results in a superior heat exchanger design. Stainless Steel Burners Precision burners, raised port design, are formed from high chromium stainless steel. Each burner assembly slides out like a drawer for quick inspection and maintenance. Low Profile Automatic Flue Damper Low profile damper minimizes overall product height. Heavy duty vent hood supports are designed to withstand the rigors of installation. Full-port, Full-flow Drain Valve Factory installed brass drain valve allows for faster draining and servicing. Direct Spark-to-Pilot Ignition System Energy saving ignition that ignites pilot only when there is a call for heat. Altitude Certifications Up to 5,000 feet for natural gas and 2,000 feet for LP; with high altitude certification kit, up to 8,000 feet. Patented Anode Rods Anode design utilizes multiple magnesium rods to ensure corrosion resistance for a long tank life. |
General Information
General Information |
N/A
Efficiency All models tested according to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction Design certified by CSA: For operation at 180 degrees; meets all safety and construction requirement of ANSI Z21.10.3; as an automatic storage or instantaneous water heater; as an automatic circulating tank water heater; and for operation on combustible floors and in alcove installations. Certified for 150 PSI maximum working pressure (160 PSI for ASME models). Optional Construction ASME construction is available on designated models. UL Sanitation (NSF5) compliant models are available when equipped with optional seal kit (Part No. AM35450). CSA/ASME Rated T&P Valve Factory installed relief valve Insulation Sag and moisture proof fiberglass insulation surrounds the storage tank and heavy mineral wool insulation surrounds the combustion chamber. Hand-hole Cleanout For easy removal of lime/sediment deposits. Manual Reset High Limit ASME models are factory equipped with manual reset high limit to meet the code requirements in many states. Gas Control System Thermostat adjusts from 100 to 180 degrees Fahrenheit, 24 volt combination gas valve includes main gas pressure regulation, on-off manual valve, 120/24 volt transformer and high limit temperature cut-out. |
Warranty
Warranty |
N/A
|
Note
Note |
N/A
All Models Require a 120 V Power Source/0.3 amps. (A) indicates available ASME model. (A) Suffix Indicates ASME Tank Construction Available. When ordering ASME construction, place (A) after the model number (for trade reference only) Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and Pressure Vessel Code, Section IV Part HLW. |