Catalog
Unit of Measure
Specifications
|
Dimensions
|
Standard Features
|
Other Standard Features
|
Optional Dual-Energy Source Capability
|
Limited Warranty Outline
|
General Information
|
Options
|
Special Construction
|
Other Optional Features
|
Control Options
|
Note
Specifications
Manufacturer |
N/A State® |
Nominal Capacity |
N/A 800 gal |
Maximum Input Power |
N/A 780 kW |
Drain Opening |
N/A 1-1/2 in |
Valve Opening |
N/A 1 in |
Standard Voltage |
N/A 208 V240 V480 V600 V |
Working Pressure |
N/A 125 psi |
Phase |
N/A Single Three |
Type |
N/A Electric |
Style |
N/A Large Volume |
Size |
N/A C |
Industry Standards |
N/A ASME Certified UL® Listed |
Dimensions
Standard Features
Standard Features |
N/A
Advanced Electronic Control provides precise + or - 1 ºF temperature control, that is ideal for industrial and food service applications where exact temperatures of hot water are needed.
|
Other Standard Features
Other Standard Features |
N/A
|
Optional Dual-Energy Source Capability
Optional Dual-Energy Source Capability |
N/A Provides emergency back up energy source or winter/summer boiler operation. Can be specified with optional water to water or steam to water heat exchangers. Both single and double-wall heat exchangers are available. Complete control packages can be factory-installed for hook up and run capability. |
Limited Warranty Outline
Limited Warranty Outline |
N/A
If the tank should leak any time during the first three years, under the terms of the warranty, State will repair or replace the heater; installation, labor, handling repair or replace the heater; installation, labor, handling and local delivery extra. This outline is not a warranty. Warranty does not apply to product installed outside of the United States of America or its territorial possessions and Canada. |
General Information
General Information |
N/A
Solid State Modulating Step Control (All Models 180 KW and up)
|
Options
Options |
N/A
Tank Linings Cement - A special formulation of cement providing excellent corrosion protection. Available on 200-gallon and larger tanks. Epoxy - A solvent less two component epoxy lining applied to a minimum ten-mil (0.010") dry thickness. Available on 200-gallon and larger tanks. |
Special Construction
Special Construction |
N/A
Stainless Steel Vessels - Are available for deionized water. Built with stainless steel under rules of Section IV of the ASME Boiler and Pressure Vessel Code for operation on deionized water having a minimum specific resistivity of 10 megohm/cm. 150 or 160 psi Working Pressure - Must be specified at time of order. |
Other Optional Features
Other Optional Features |
N/A
Temperature and Pressure Relife Valves - For working pressures other than standard; consult factory. Horizontal and Vertical - Most gallon capacities may be obtained in vertical or horizontal construction. Circulating Pump Package - Circulating pump and piping sized to turn over entire storage capacity of tank once each hour. Recommended to optimize available water at temperature in horizontal tanks particularly where low draw conditions are anticipated. Optional International Voltages - 380 and 415 volts three phase. 3-1/2" Dial-Type Pressure Gauge - Factory-installed. 3-1/2" Dial-Type Temperature Gauge - Factory-installed. 11" x 15" Manhole - Available as option on tanks 700 gallons or smaller. |
Control Options
Control Options |
N/A
Copper Tube Tank Heater - Double wall copper tube tank heaters are designed for heating potable water with both potable or non-potable liquids or steam, and are specifically engineered for installation in models SEV and SEH for dual-energy applications. Tank heaters have a positive fail-safe means of leak detection in the event of either tube failure to prevent mixture of heating medium and potable water. Singlewall heat exchangers are also available. Terminal Blocks - Allows for remote connection to building demand limiter or other functions. Automatic Reset High Limit - A control that in the event of high temperature, interrupts power, de-energizing elements, automatic reset. (Standard with modulating step control). Indicating Lights - Denotes heating stage(s) in operation. Up to one light per contactor is available. Override Switches - A simple means of load control allows all or part of unit input to be controlled manually. Up to one switch per contactor is available. Safety Door Interlock - Prevents opening of control panel door when heater power supply is on. NOTE: Once door is opened heater may be energized if necessary for service diagnosis. Shunt Trip Circuit Breaker - A safety device (circuit breaker) which disconnects power to heater in the event of over-current, high temperature or low water level, breaker must be manually reset. Circuit Breaker - A safety device which disconnects power to the heater in the event of overcurrent. |