            The American Standard® Commercial Gas Model D-100-270-AS is designed to deliver large quantities of hot water economically through utilization of the most energy-saving techniques. Customary applications include industrial buildings, motels, hotels, schools, hospitals, restaurants, laundromats, car washes and multi-family developments up to eighteen single or thirteen double bath units.
        
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Dimensions
                            |
                        Maximum Recovery
                            |
                        Maximum Hot Water Delivery
                            |
                        Electrical Characteristics
                            |
                        Testing and Certifications
                            |
                        Features
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
                                                                                Manufacturer | 
                                                                        N/A American Standard® | 
                                                                                Tank Capacity | 
                                                                        N/A 100 gal | 
                                                                                Input Power | 
                                                                        N/A 270000 BTU | 
                                                                                Type | 
                                                                        N/A Liquid Propane Gas | 
                                                                                Thermal Efficiency | 
                                                                        N/A 80 % | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Test Pressure | 
                                                                        N/A 300 psi | 
                                                                                Working Pressure | 
                                                                        N/A 150 psi | 
                                                                                Industry Standards | 
                                                                        N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 NSF | 
Dimensions
Maximum Recovery
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 655 gal/h | 
                                                                                Recovery at 50 ºF Temperature Rise | 
                                                                        N/A 524 gal/h | 
                                                                                Recovery at 60 ºF Temperature Rise | 
                                                                        N/A 436 gal/h | 
                                                                                Recovery at 70 ºF Temperature Rise | 
                                                                        N/A 374 gal/h | 
                                                                                Recovery at 80 ºF Temperature Rise | 
                                                                        N/A 327 gal/h | 
                                                                                Recovery at 90 ºF Temperature Rise | 
                                                                        N/A 291 gal/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 262 gal/h | 
                                                                                Recovery at 110 ºF Temperature Rise | 
                                                                        N/A 238 gal/h | 
                                                                                Recovery at 120 ºF Temperature Rise | 
                                                                        N/A 218 gal/h | 
                                                                                Recovery at 130 ºF Temperature Rise | 
                                                                        N/A 201 gal/h | 
                                                                                Recovery at 140 ºF Temperature Rise | 
                                                                        N/A 187 gal/h | 
Maximum Hot Water Delivery
                                                                                Storage Capacity | 
                                                                        N/A 100 U.S. gal | 
                                                                                One Hour Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 262 gal/h | 
                                                                                Maximum Hot Water Delivery (1 Hour) | 
                                                                        N/A 332 L | 
                                                                                Maximum Hot Water Delivery (2 Hours) | 
                                                                        N/A 594 L | 
                                                                                Maximum Hot Water Delivery (3 Hours) | 
                                                                        N/A 856 L | 
                                                                                Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 4.4 g/min | 
Testing and Certifications
                                                                                Testing and Certifications | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Features
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Warranty
                                                                                Warranty | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Note
                                                                                Note | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          This water heater meets the requirements of ASHRAE 90.1-1999 and meets or exceeds the thermal efficiency and standby loss requirements of california and other states recognizing ASHRAE. Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.  | 
                                                    