Catalog
		
            The American Standard® Commercial Gas Model 75-76-AS is designed to fill the hot water requirements of large residences, small restaurants, businesses, barber and beauty shops, small office buildings and multi-family developments up to four single or three double bath units.
        
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Dimensions
                            |
                        Maximum Recovery
                            |
                        Maximum Hot Water Delivery
                            |
                        Testing and Certifications
                            |
                        Features
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
                                                                                Manufacturer | 
                                                                        N/A American Standard® | 
                                                                                Tank Capacity | 
                                                                        N/A 75 gal | 
                                                                                Input Power | 
                                                                        N/A 76100 BTU | 
                                                                                Type | 
                                                                        N/A Natural Gas | 
                                                                                Model Type | 
                                                                        N/A SCAQMD Low NOx | 
                                                                                Thermal Efficiency | 
                                                                        N/A 80 % | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Test Pressure | 
                                                                        N/A 300 psi | 
                                                                                Working Pressure | 
                                                                        N/A 150 psi | 
                                                                                Industry Standards | 
                                                                        N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 NSF | 
Dimensions
Maximum Recovery
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 185 gal/h | 
                                                                                Recovery at 50 ºF Temperature Rise | 
                                                                        N/A 148 gal/h | 
                                                                                Recovery at 60 ºF Temperature Rise | 
                                                                        N/A 123 gal/h | 
                                                                                Recovery at 70 ºF Temperature Rise | 
                                                                        N/A 105 gal/h | 
                                                                                Recovery at 80 ºF Temperature Rise | 
                                                                        N/A 92 gal/h | 
                                                                                Recovery at 90 ºF Temperature Rise | 
                                                                        N/A 82 gal/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 74 gal/h | 
                                                                                Recovery at 110 ºF Temperature Rise | 
                                                                        N/A 67 gal/h | 
                                                                                Recovery at 120 ºF Temperature Rise | 
                                                                        N/A 62 gal/h | 
                                                                                Recovery at 130 ºF Temperature Rise | 
                                                                        N/A 57 gal/h | 
                                                                                Recovery at 140 ºF Temperature Rise | 
                                                                        N/A 53 gal/h | 
Maximum Hot Water Delivery
                                                                                Storage Capacity | 
                                                                        N/A 75 U.S. gal | 
                                                                                One Hour Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 74 gal/h | 
                                                                                Maximum Hot Water Delivery (1 Hour) | 
                                                                        N/A 127 L | 
                                                                                Maximum Hot Water Delivery (2 Hours) | 
                                                                        N/A 201 L | 
                                                                                Maximum Hot Water Delivery (3 Hours) | 
                                                                        N/A 275 L | 
                                                                                Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 1.2 g/min | 
Testing and Certifications
                                                                                Testing and Certifications | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Features
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Warranty
                                                                                Warranty | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Note
                                                                                Note | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          This water heater meets the requirements of ASHRAE and meets or exceeds the thermal efficiency requirements of california and other states recognizing ASHRAE. Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.  | 
                                                    