Catalog
		
            Designed as the Universal Replacement for All brands of Non-Ultra-Low NOx commercial models
Ultra-Low NOx Heavy Duty Commercial Product Offering - The most complete line - 12 models ranging from 125,000 BTU to 512,000 BTU input.
Ultra-Low NOx Heavy Duty Commercial Product Offering - The most complete line - 12 models ranging from 125,000 BTU to 512,000 BTU input.
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Dimensions
                            |
                        Maximum Hot Water Delivery
                            |
                        Maximum Recovery
                            |
                        Features
                            |
                        Testing and Certifications
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
                                                                                Manufacturer | 
                                                                        N/A American Standard® | 
                                                                                Tank Capacity | 
                                                                        N/A 80 gal | 
                                                                                Input Power | 
                                                                        N/A 180000 BTU | 
                                                                                Thermal Efficiency | 
                                                                        N/A 80.04 % | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Type | 
                                                                        N/A Natural Gas | 
                                                                                Industry Standards | 
                                                                        N/A C.E.C. Listed ETL | 
Dimensions
Maximum Hot Water Delivery
                                                                                One Hour Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 174.5 gal/h | 
                                                                                Maximum Hot Water Delivery (1 Hour) | 
                                                                        N/A 231 L | 
                                                                                Maximum Hot Water Delivery (2 Hours) | 
                                                                        N/A 406 L | 
                                                                                Maximum Hot Water Delivery (3 Hours) | 
                                                                        N/A 581 L | 
                                                                                Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 2.9 g/min | 
                                                                                Storage Capacity | 
                                                                        N/A 80 U.S. gal | 
Maximum Recovery
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 430.1 gal/h | 
                                                                                Recovery at 50 ºF Temperature Rise | 
                                                                        N/A 344.1 gal/h | 
                                                                                Recovery at 60 ºF Temperature Rise | 
                                                                        N/A 286.7 gal/h | 
                                                                                Recovery at 70 ºF Temperature Rise | 
                                                                        N/A 245.8 gal/h | 
                                                                                Recovery at 80 ºF Temperature Rise | 
                                                                        N/A 215 gal/h | 
                                                                                Recovery at 90 ºF Temperature Rise | 
                                                                        N/A 191.1 gal/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 174.5 gal/h | 
                                                                                Recovery at 110 ºF Temperature Rise | 
                                                                        N/A 156.4 gal/h | 
                                                                                Recovery at 120 ºF Temperature Rise | 
                                                                        N/A 143.3 gal/h | 
                                                                                Recovery at 130 ºF Temperature Rise | 
                                                                        N/A 132.3 gal/h | 
                                                                                Recovery at 140 ºF Temperature Rise | 
                                                                        N/A 122.9 gal/h | 
Features
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Testing and Certifications
                                                                                Testing and Certifications | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          ETL Design Certified in accordance with ANSI Z21.10.3 for up  to 180 degree operation as an automatic storage and/or automatic  circulation tank heater and meets ASHRAE  90.1-1999 CEC listed, ETL certified to meet NSF/ANSI 5 Standards  | 
                                                    



