Catalog
		
            For medium-demand commercial applications, State Titan™ (GPG and GPV) commercial gas water heaters offer precise power burner performance, plus flexible venting options including conventional atmospheric venting, sidewall venting or direct venting. Professional start-up service is also available from State on these Titan™ units to help ensure optimum performance.
        
                    Unit of Measure
                    
               
        
            
                        Specifications
                            |
                        Maximum Recovery
                            |
                        Dimensions
                            |
                        Features
                            |
                        Testing and Certifications
                            |
                        Warranty
                            |
                        Note
                
            
            Specifications
                                                                                Manufacturer | 
                                                                        N/A State® | 
                                                                                Input Power | 
                                                                        N/A 740000 BTU/hr | 
                                                                                Tank Capacity | 
                                                                        N/A 85 U.S. gal | 
                                                                                First Hour Rating at 100 ºF Temperature Rise | 
                                                                        N/A 778 U.S. gal | 
                                                                                Gas Connection | 
                                                                        N/A 1 in25.4 mm | 
                                                                                Type | 
                                                                        N/A Natural Gas | 
                                                                                Style | 
                                                                        N/A State Titan® | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Approximate Shipping Weight | 
                                                                        N/A 950 lb431 kg | 
                                                                                Industry Standards | 
                                                                        N/A AHRI Certified® ASME Certified CSA® Certified Start-Up UL® Listed | 
                                                                                Maximum Working Pressure | 
                                                                        N/A 160 psi | 
Maximum Recovery
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 1794 gal/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 718 gal/h | 
                                                                                Recovery at 140 ºF Temperature Rise | 
                                                                        N/A 512 gal/h | 
Dimensions
Features
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          Powered Gas Low NOx Burner (Natural Gas Only)
 
 
 
 
 Factory-Installed CSA Certified and ASME Rated T & P Relief Valve Glasslined Tank 
 Handhole Cleanout 
  | 
                                                    
Testing and Certifications
                                                                                Testing and Certifications | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
Note
                                                                                Note | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 5.0 amps, use 15 amps supply power. Minimum gas supply pipe size is 1 1/4". Maximum supply gas pressure 14" W.C.  | 
                                                    