                                                                                Manufacturer | 
                                                                        N/A American Standard® | 
                                                                                Tank Capacity | 
                                                                        N/A 100 gal | 
                                                                                Input Power | 
                                                                        N/A 300000 BTU | 
                                                                                Type | 
                                                                        N/A Natural Gas | 
                                                                                Thermal Efficiency | 
                                                                        N/A 80 % | 
                                                                                Size | 
                                                                        N/A C | 
                                                                                Test Pressure | 
                                                                        N/A 300 psi | 
                                                                                Working Pressure | 
                                                                        N/A 150 psi | 
                                                                                Industry Standards | 
                                                                        N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 ASME Certified NSF | 
                                                                                Recovery at 40 ºF Temperature Rise | 
                                                                        N/A 727 gal/h | 
                                                                                Recovery at 50 ºF Temperature Rise | 
                                                                        N/A 582 gal/h | 
                                                                                Recovery at 60 ºF Temperature Rise | 
                                                                        N/A 485 gal/h | 
                                                                                Recovery at 70 ºF Temperature Rise | 
                                                                        N/A 416 gal/h | 
                                                                                Recovery at 80 ºF Temperature Rise | 
                                                                        N/A 364 gal/h | 
                                                                                Recovery at 90 ºF Temperature Rise | 
                                                                        N/A 323 gal/h | 
                                                                                Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 291 gal/h | 
                                                                                Recovery at 110 ºF Temperature Rise | 
                                                                        N/A 265 gal/h | 
                                                                                Recovery at 120 ºF Temperature Rise | 
                                                                        N/A 242 gal/h | 
                                                                                Recovery at 130 ºF Temperature Rise | 
                                                                        N/A 224 gal/h | 
                                                                                Recovery at 140 ºF Temperature Rise | 
                                                                        N/A 208 gal/h | 
                                                                                Storage Capacity | 
                                                                        N/A 100 U.S. gal | 
                                                                                One Hour Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 291 gal/h | 
                                                                                Maximum Hot Water Delivery (1 Hour) | 
                                                                        N/A 361 L | 
                                                                                Maximum Hot Water Delivery (2 Hours) | 
                                                                        N/A 652 L | 
                                                                                Maximum Hot Water Delivery (3 Hours) | 
                                                                        N/A 943 L | 
                                                                                Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise | 
                                                                        N/A 4.9 g/min | 
                                                                                Testing and Certifications | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
                                                                                Features | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
                                                                                Warranty | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          
  | 
                                                    
                                                                                Note | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          This water heater meets the requirements of ASHRAE 90.1-1999 and meets or exceeds the thermal efficiency and standby loss requirements of california and other states recognizing ASHRAE. Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.  |