Catalog
Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters
Bradford White® Ultra-Low NOx Commercial Water Heaters
Unit of Measure
Items |
/Asset/a1338.jpg UDH-50T-45FR-3N Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif UDH-50T-45FR-5N Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif UDH-65T-45FR-3N Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif UDH-65T-45FR-5N Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif UDH-75T-50FR-3N Light Duty Commercial Ultra-Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Capacity | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 65 U.S. gal54 Imp. gal246 L | N/A 65 U.S. gal54 Imp. gal246 L | N/A 75 U.S. gal62 Imp. gal284 L | |||||
Input Power | N/A 45000 BTU/hr13.8 kW | N/A 45000 BTU/hr13.8 kW | N/A 45000 BTU/hr13.8 kW | N/A 45000 BTU/hr13.8 kW | N/A 50000 BTU/hr14.6 kW | |||||
First Hour Rating1 | N/A 88 gal333 L | N/A 88 gal333 L | N/A 101 gal382 L | N/A 101 gal382 L | N/A 110 gal416 L | |||||
Recovery at 100 ºF Temperature Rise |
N/A 43 U.S. gal/h35 Imp. gal/h | N/A 43 U.S. gal/h35 Imp. gal/h | N/A 43 U.S. gal/h35 Imp. gal/h | N/A 43 U.S. gal/h35 Imp. gal/h | N/A 48 U.S. gal/h40 Imp. gal/h | |||||
Recovery at 56 ºC Temperature Rise |
N/A 163 L/h | N/A 163 L/h | N/A 163 L/h | N/A 163 L/h | N/A 182 L/h | |||||
Schematic |
N/A
Schematic Drawing for Light Duty Commercial Ultra Low NOx High Input Direct Vent Energy Saver Gas Water Heaters |
|||||||||
Floor to Center Line of Vent A | N/A 75-1/4 in1411 mm | N/A 75-1/4 in1411 mm | N/A 78-1/4 in1988 mm | N/A 78-1/4 in1988 mm | N/A 75-1/2 in1918 mm | |||||
Jacket Diameter B | N/A 20 in508 mm | N/A 20 in508 mm | N/A 22 in559 mm | N/A 22 in559 mm | N/A 24 in610 mm | |||||
Vent Size C | N/A 4 to 6 in102 to 152 mm | |||||||||
Floor to T and P Connection D | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 56 in1422 mm | N/A 56 in1422 mm | N/A 52 in1321 mm | |||||
Floor to Gas Connection E | N/A 15 in381 mm | |||||||||
Floor to Top of Heater F | N/A 58-3/4 in1492 mm | N/A 58-3/4 in1492 mm | N/A 62 in1575 mm | N/A 62 in1575 mm | N/A 59 in1499 mm | |||||
Floor to Space Heating Outlet G | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 56 in1422 mm | N/A 56 in1422 mm | N/A 52 in1320 mm | |||||
Floor to Water Connection H | N/A 59-3/4 in1518 mm | N/A 59-3/4 in1518 mm | N/A 63 in1600 mm | N/A 63 in1600 mm | N/A 60 in1524 mm | |||||
Floor to Space Heating Inlet J | N/A 15-3/4 in400 mm | N/A 15-3/4 in400 mm | N/A 15-3/4 in400 mm | N/A 15-3/4 in400 mm | N/A 16-1/2 in419 mm | |||||
Depth K | N/A 31-1/4 in768 mm | N/A 31-1/4 in768 mm | N/A 34-1/4 in864 mm | N/A 34-1/4 in864 mm | N/A 35-1/4 in889 mm | |||||
Approximate Shipping Weight | N/A 190 lb86 kg | N/A 190 lb86 kg | N/A 226 lb102 kg | N/A 226 lb102 kg | N/A 261 lb118 kg | |||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Gas Connection | N/A 1/2 in13 mm | |||||||||
Type | N/A Natural Gas | |||||||||
Style | N/A Light-Duty Ultra Low NOx High Input Direct Vent | |||||||||
Size | N/A C | |||||||||
Industry Standards | N/A AHRI Certified® ANSI CSA® Certified | |||||||||
Optional Telescoping Solid Vent Kits |
N/A
Kit "F" - Telescopes from 4-3/4" to 5-11/16" - Part No. 239-42516-00 Kit "G" - Telescopes from 6-1/2" to 9-3/16" - Part No. 239-42517-00 Kit "H" - Telescopes from 13-3/4" to 23-11/16" - Part No. 239-42514-00 Kit "I" - Telescopes from 49-13/16" to 95-13/16" - Part No. 239-42512-00 |
|||||||||
Features |
N/A
The Direct Vent FVIR Eco-Defender Safety System® Models Feature:
|
|||||||||
Warranty |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All potable water connections are 3/4" NPT (19 mm) on 11" (203 mm) centers. All gas connections 1/2" (13 mm). All models design certified by CSA® International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. |
|||||||||
Note |
N/A
Telescoping Solid Vent Kit (239-47811-00) or Flexible Vent Kit (239-47813-00) can be ordered and shipped with water heater, or ordered and shipped separately. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 78% Recovery Efficiency. |
|||||||||
|