/Asset/a1373.jpg HE-70-125 High Efficiency Series Commercial Gas Water Heaters |
/Asset/a1373.jpg HE-70-125-LP High Efficiency Series Commercial Gas Water Heaters |
/Asset/a1373.jpg HE-100-150 High Efficiency Series Commercial Gas Water Heaters |
/Asset/a1373.jpg HE-100-199 High Efficiency Series Commercial Gas Water Heaters |
/Asset/a1373.jpg HE-100-250 High Efficiency Series Commercial Gas Water Heaters |
|||||
| Manufacturer | N/A American Standard® | |||||||||
| Capacity | N/A 70 U.S. gal | N/A 70 U.S. gal | N/A 100 U.S. gal | N/A 100 U.S. gal | N/A 100 U.S. gal | |||||
| Input Power | N/A 125000 BTU | N/A 125000 BTU | N/A 150000 BTU | N/A 199000 BTU | N/A 250000 BTU | |||||
| First Hour Delivery at 100 ºF Temperature Rise | N/A 195 | N/A 195 | N/A 245 | N/A 305 | N/A 358 | |||||
| Thermal Efficiency | N/A 96.4 % | N/A 96.4 % | N/A 98 % | N/A 97.5 % | N/A 95.3 % | |||||
| Schematic |
N/A
![]() Schematic Drawing for High Efficiency Series Commercial Gas Water Heaters |
|||||||||
| Floor to Top of Heater A | N/A 69 in | N/A 69 in | N/A 76-7/8 in | N/A 76-7/8 in | N/A 76-7/8 in | |||||
| Floor to Cold Water Inlet B | N/A 7-1/4 in | |||||||||
| Floor to Hot Water Outlet C | N/A 63-3/4 in | N/A 63-3/4 in | N/A 71-1/2 in | N/A 71-1/2 in | N/A 71-1/2 in | |||||
| Floor to Air Intake D | N/A 60-1/8 in | N/A 60-1/8 in | N/A 68-1/8 in | N/A 68-1/8 in | N/A 68-1/8 in | |||||
| Floor to Exhaust E | N/A 9-1/4 in | |||||||||
| Floor to Top T and P | N/A 51 in | N/A 51 in | N/A 58 in | N/A 58 in | N/A 58 in | |||||
| Heater Diameter G | N/A 26-3/8 in | N/A 26-3/8 in | N/A 28-3/8 in | N/A 28-3/8 in | N/A 28-3/8 in | |||||
| Floor to Drain H | N/A 5-1/2 in | |||||||||
| Floor to Gas Inlet J | N/A 62-1/4 in | N/A 62-1/4 in | N/A 70-1/4 in | N/A 70-1/4 in | N/A 70-1/4 in | |||||
| Water Connection (In) | N/A 1-1/2 in | |||||||||
| Water Connection (Out) | N/A 1-1/2 in | |||||||||
| Gas Connection | N/A 1/2 in | |||||||||
| T and P Connection | N/A 3/4 in | N/A 3/4 in | N/A 3/4 in | N/A 3/4 in | N/A 1 in | |||||
| Approximate Shipping Weight | N/A 290 lb | N/A 290 lb | N/A 490 lb | N/A 490 lb | N/A 490 lb | |||||
| Recovery at 30 ºF Temperature Rise | N/A 487 gal/h | N/A 487 gal/h | N/A 594 gal/h | N/A 784 gal/h | N/A 963 gal/h | |||||
| Recovery at 40 ºF Temperature Rise | N/A 365 gal/h | N/A 365 gal/h | N/A 446 gal/h | N/A 588 gal/h | N/A 722 gal/h | |||||
| Recovery at 50 ºF Temperature Rise | N/A 292 gal/h | N/A 292 gal/h | N/A 356 gal/h | N/A 470 gal/h | N/A 578 gal/h | |||||
| Recovery at 60 ºF Temperature Rise | N/A 365 gal/h | N/A 365 gal/h | N/A 297 gal/h | N/A 392 gal/h | N/A 418 gal/h | |||||
| Recovery at 70 ºF Temperature Rise | N/A 209 gal/h | N/A 209 gal/h | N/A 255 gal/h | N/A 336 gal/h | N/A 413 gal/h | |||||
| Recovery at 80 ºF Temperature Rise | N/A 183 gal/h | N/A 183 gal/h | N/A 223 gal/h | N/A 294 gal/h | N/A 361 gal/h | |||||
| Recovery at 90 ºF Temperature Rise | N/A 162 gal/h | N/A 162 gal/h | N/A 198 gal/h | N/A 261 gal/h | N/A 321 gal/h | |||||
| Recovery at 100 ºF Temperature Rise | N/A 146 gal/h | N/A 146 gal/h | N/A 175 gal/h | N/A 235 gal/h | N/A 288 gal/h | |||||
| Recovery at 110 ºF Temperature Rise | N/A 133 gal/h | N/A 133 gal/h | N/A 162 gal/h | N/A 214 gal/h | N/A 263 gal/h | |||||
| Recovery at 120 ºF Temperature Rise | N/A 122 gal/h | N/A 122 gal/h | N/A 149 gal/h | N/A 196 gal/h | N/A 241 gal/h | |||||
| Recovery at 130 ºF Temperature Rise | N/A 112 gal/h | N/A 112 gal/h | N/A 137 gal/h | N/A 181 gal/h | N/A 222 gal/h | |||||
| Recovery at 140 ºF Temperature Rise | N/A 104 gal/h | N/A 104 gal/h | N/A 127 gal/h | N/A 168 gal/h | N/A 206 gal/h | |||||
| Sides Installation Clearances | N/A 0 in | |||||||||
| Front Installation Clearances | N/A 0 in | |||||||||
| Rear Installation Clearances | N/A 0 in | |||||||||
| Top Installation Clearances | N/A 0 in | |||||||||
| To Combustible Installation Clearances | N/A 0 in | |||||||||
| Maximum Equivalent Vent Length using 2" Pipe PVC, ABS, and CPVC | N/A 65 ft | |||||||||
| Maximum Equivalent Vent Length using 3" Pipe PVC, ABS, and CPVC | N/A 135 ft | |||||||||
| Maximum Equivalent Vent Length using 4" Pipe PVC, ABS, and CPVC | N/A 135 ft | |||||||||
| Gas Valve Piping at Inlet Size | N/A 1/2 in | |||||||||
| Type | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | N/A Natural Gas | N/A Natural Gas | |||||
| Size | N/A C | |||||||||
| Industry Standards | N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 ETL | |||||||||
| Testing and Certifications |
N/A
|
|||||||||
| Features |
N/A
|
|||||||||
| Warranty |
N/A
|
|||||||||
| Note | N/A Manufacturer reserves the right to make product changes and/or improvements with or without notice. | |||||||||
|
|
||||||||||