Catalog
Designed for use as a recovery heater having its own storage tank or booster for supplying sanitizing rinse water for dishwashing.
Unit of Measure
Specifications
|
Maximum Recovery
|
Dimensions
|
Electrical Characteristics
|
Features
|
Other Standard Features
|
Options
|
Warranty
|
Note
Specifications
Manufacturer |
N/A State® |
Tank Capacity |
N/A 80 gal300 L |
Standard Input Power |
N/A 15 kW |
Input Power |
N/A 51195 BTU/hr |
Inlet/Outlet (NPT) |
N/A 1-1/4 in3.2 cm |
Approximate Shipping Weight |
N/A 280 lb127 kg |
Number of Elements |
N/A 3 |
Element Power |
N/A 5000 W |
Voltage |
N/A 208 V240 V277 V480 V |
Phase |
N/A Single Three |
Working Pressure |
N/A 150 psi1034 kPa |
Temperature Range |
N/A 90 to 190 ºF |
Style |
N/A Sandblaster® Immersion Mount |
Size |
N/A C |
Type |
N/A Electric |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed |
Maximum Recovery
Recovery at 30 ºF Temperature Rise |
N/A 205 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 775 L/h |
Recovery at 40 ºF Temperature Rise |
N/A 154 gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 582 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 123 gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 465 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 102 gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 388 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 88 gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 332 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 77 gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 291 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 68 gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 258 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 61 gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 233 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 56 gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 211 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 51 gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 194 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 47 gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 149 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 44 gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 166 L/h |
Electrical Characteristics
Full Load Current Single Phase 208 V |
N/A 72.1 A |
Full Load Current Single Phase 240 V |
N/A 62.5 A |
Full Load Current Single Phase 277 V |
N/A 54.2 A |
Full Load Current Single Phase 480 V |
N/A 31.3 A |
Full Load Current Three Phase 208 V |
N/A 41.6 A |
Full Load Current Three Phase 240 V |
N/A 36.1 A |
Full Load Current Three Phase 480 V |
N/A 18.0 A |
Features
Features |
N/A
Meets the standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1. Advanced Electronic Control - Plain English text and animated icons display detailed operational and diagnostic information. Fault or Alert messages appear if an operational issue occurs. Immersion temperature control adjustable through a range of 90 ºF to 190 ºF.
Linear Sequencing - Banks of heating elements (3 elements per bank) are energized according to adjustable (1 to 20º) differential set points for each bank. First bank on is the last bank off. Helps reduce current surge and provides accurate water temperature control. Gold Elements - CSB models ship with the gold plated elements (see element availability chart on back). Patented elements provide long life and superior scaling resistance. Low watt density means lower surface temperature to minimize scale buildup and more surface to heat water. Gold elements carry a one-year warranty against failure due to lime scale buildup. Glasslined Tank - Three sizes: 50, 80, and 119-gallon capacity. Tank interior is coated with glass specially developed for water heater use. Tanks rated at 150 psi (1034 kPa) working pressure (ASME 150 psi). Foam insulation reduces costly heat loss, and is vermin proof. Fusing - Protects all elements, thermostats, and internal wiring circuits against excess current flow. Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps. Standard Voltages - 208, 240, and 480 V single-phase and three-phase delta. Convertible from three-phase to single-phase (in field) and vice versa. 277 V single-phase also available. Terminal Block - Factory installed. Just bring the service to the heater and connect to block. Magnetic Contactors - Heavy duty, UL rated 100,000 cycles. |
Other Standard Features
Other Standard Features |
N/A
|
Options
Options |
N/A
|