Items |
G50-65LP Medium Duty Commercial Gas Water Heaters |
G60-50LP Medium Duty Commercial Gas Water Heaters |
G65-65LP Medium Duty Commercial Gas Water Heaters |
G75-75LP Medium Duty Commercial Gas Water Heaters |
G100-65LP Medium Duty Commercial Gas Water Heaters |
|||||
Manufacturer | N/A Rheem® | |||||||||
Maximum Working Pressure | N/A 150 psi | |||||||||
Input Power | N/A 48000 BTU/hr | N/A 45000 BTU/hr | N/A 50000 BTU/hr | N/A 65000 BTU/hr | N/A 65000 BTU/hr | |||||
Type | N/A Liquid Propane Gas | |||||||||
Capacity | N/A 48 U.S. gal | N/A 60 U.S. gal | N/A 63 U.S. gal | N/A 75 U.S. gal | N/A 98 U.S. gal | |||||
Minimum to Recovery Contents | N/A 65 | N/A 87 | N/A 82 | N/A 75 | N/A 98 | |||||
Approximate Shipping Weight | N/A 180 lb | N/A 180 lb | N/A 225 lb | N/A 320 lb | N/A 350 lb | |||||
Water Connection | N/A 3/4 in. NPT | N/A 3/4 in. NPT | N/A 3/4 in. NPT | N/A 1 in. NPT | N/A 1 in. NPT | |||||
Tank Material | N/A Steel | |||||||||
Finish | N/A Porcelain Enamel | |||||||||
Equipment Grade | N/A Commercial | |||||||||
Recovery at 40 ºF Temperature Rise | N/A 111 U.S. gal/h | N/A 104 U.S. gal/h | N/A 115 U.S. gal/h | N/A 150 U.S. gal/h | N/A 150 U.S. gal/h | |||||
Recovery at 50 ºF Temperature Rise | N/A 88 U.S. gal/h | N/A 83 U.S. gal/h | N/A 92 U.S. gal/h | N/A 120 U.S. gal/h | N/A 120 U.S. gal/h | |||||
Recovery at 60 ºF Temperature Rise | N/A 74 U.S. gal/h | N/A 69 U.S. gal/h | N/A 77 U.S. gal/h | N/A 100 U.S. gal/h | N/A 100 U.S. gal/h | |||||
Recovery at 70 ºF Temperature Rise | N/A 63 U.S. gal/h | N/A 59 U.S. gal/h | N/A 66 U.S. gal/h | N/A 86 U.S. gal/h | N/A 86 U.S. gal/h | |||||
Recovery at 80 ºF Temperature Rise | N/A 55 U.S. gal/h | N/A 52 U.S. gal/h | N/A 58 U.S. gal/h | N/A 75 U.S. gal/h | N/A 75 U.S. gal/h | |||||
Recovery at 90 ºF Temperature Rise | N/A 49 U.S. gal/h | N/A 46 U.S. gal/h | N/A 51 U.S. gal/h | N/A 67 U.S. gal/h | N/A 67 U.S. gal/h | |||||
Recovery at 100 ºF Temperature Rise | N/A 44 U.S. gal/h | N/A 41 U.S. gal/h | N/A 46 U.S. gal/h | N/A 60 U.S. gal/h | N/A 60 U.S. gal/h | |||||
Recovery at 110 ºF Temperature Rise | N/A 40 U.S. gal/h | N/A 38 U.S. gal/h | N/A 42 U.S. gal/h | N/A 54 U.S. gal/h | N/A 54 U.S. gal/h | |||||
Recovery at 120 ºF Temperature Rise | N/A 37 U.S. gal/h | N/A 35 U.S. gal/h | N/A 38 U.S. gal/h | N/A 50 U.S. gal/h | N/A 50 U.S. gal/h | |||||
Recovery at 130 ºF Temperature Rise | N/A 34 U.S. gal/h | N/A 32 U.S. gal/h | N/A 35 U.S. gal/h | N/A 46 U.S. gal/h | N/A 46 U.S. gal/h | |||||
Maximum Delivery at 100 ºF (5 Minutes) | N/A 37 U.S. gal | N/A 45 U.S. gal | N/A 48 U.S. gal | N/A 56 U.S. gal | N/A 74 U.S. gal | |||||
Maximum Delivery at 100 ºF (10 Minutes) | N/A 41 U.S. gal | N/A 49 U.S. gal | N/A 52 U.S. gal | N/A 63 U.S. gal | N/A 79 U.S. gal | |||||
Maximum Delivery at 100 ºF (15 Minutes) | N/A 45 U.S. gal | N/A 52 U.S. gal | N/A 56 U.S. gal | N/A 68 U.S. gal | N/A 84 U.S. gal | |||||
Maximum Delivery at 100 ºF (20 Minutes) | N/A 48 U.S. gal | N/A 56 U.S. gal | N/A 60 U.S. gal | N/A 73 U.S. gal | N/A 89 U.S. gal | |||||
Maximum Delivery at 100 ºF (30 Minutes) | N/A 56 U.S. gal | N/A 63 U.S. gal | N/A 67 U.S. gal | N/A 82 U.S. gal | N/A 99 U.S. gal | |||||
Maximum Delivery at 100 ºF (45 Minutes) | N/A 67 U.S. gal | N/A 73 U.S. gal | N/A 79 U.S. gal | N/A 97 U.S. gal | N/A 114 U.S. gal | |||||
Maximum Delivery at 100 ºF (60 Minutes) | N/A 78 U.S. gal | N/A 84 U.S. gal | N/A 90 U.S. gal | N/A 112 U.S. gal | N/A 129 U.S. gal | |||||
Maximum Delivery at 100 ºF (120 Minutes) | N/A 122 U.S. gal | N/A 125 U.S. gal | N/A 136 U.S. gal | N/A 172 U.S. gal | N/A 189 U.S. gal | |||||
Maximum Delivery at 100 ºF (180 Minutes) | N/A 166 U.S. gal | N/A 166 U.S. gal | N/A 182 U.S. gal | N/A 232 U.S. gal | N/A 248 U.S. gal | |||||
Schematic |
N/A
Schematic for Medium Duty Gas Commercial Water Heaters |
|||||||||
Dimension A | N/A 62-1/2 in | N/A 62 in | N/A 65 in | N/A 64 in | N/A 67-3/4 in | |||||
Dimension B | N/A 58-1/2 in | N/A 58 in | N/A 61-1/4 in | N/A 60 in | N/A 64 in | |||||
Dimension C | N/A 21-3/4 in | N/A 23 in | N/A 23 in | N/A 26-1/4 in | N/A 27-1/4 in | |||||
Dimension D | N/A 14 in | N/A 13-1/4 in | N/A 14 in | N/A 13-1/4 in | N/A 14-3/8 in | |||||
Dimension E | N/A 4 in | |||||||||
Dimension F | N/A 11 in | N/A 8 in | N/A 11 in | N/A 11 in | N/A 11 in | |||||
Dimension G | N/A 51-3/4 in | N/A 48-1/2 in | N/A 54-3/4 in | N/A 53-1/4 in | N/A 57-3/16 in | |||||
Side Clearance to Combustibles | N/A 0 in | N/A 1 in | N/A 0 in | N/A 1 in | N/A 1 in | |||||
Front Clearance to Combustibles | N/A 3 in | |||||||||
Top Clearance to Combustibles | N/A 12 in | N/A 2 in | N/A 12 in | N/A 2 in | N/A 12 in | |||||
Industry Standards | N/A AHRI Certified® ANSI Standards Z-21.10.3 ANSI Z-21.10.1 ASHRAE Standards ASME Certified CSA® Certified | |||||||||
Features and Benefits |
N/A
The tighter the commercial retrofit, the more you will appreciate how this water heater's compact size simplifies installations. Choose from 80% Thermal Efficiency models that range from 45,000 to 80,000 Btu/h and have a maximum temperature setting of 160 degrees Fahrenheit. Space Saver Design Short heights and narrow jacket diameters offer the ultimate in installation flexibility. Patented Technology Proprietary steel formulation with a unique coat of high temperature porcelain enamel to maximize corrosion resistance resulting in a superior tank design. Patented Anode Rods Magnesium anode rods are used to ensure corrosion resistance for a long tank life. Efficiency Rigid foam insulation provides superior insulating qualities, improves efficiency and reduces operating costs. Our patented process of injecting foam into the insulating cavity adds additional durability. Automatic Controls Control system is designed to shut off gas if the pilot flame is extinguished. Relighting is a safe, easy procedure. Thermostat settings to 160 ºF. A built-in gas pressure regulator assures even gas flow. Full Port, Full Flow Brass Drain Valve Factory installed brass drain valve allows for faster draining and servicing. |
|||||||||
Testing and Certifications |
N/A
CSA®/ASME Rated T&P Valve Factory installed relief valve |
|||||||||
General Information |
N/A
Efficiency These models have been tested according to DOE test procedures, and meet or exceed the thermal efficiency and standby loss requirements of current ASHRAE standards (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction These products are design certified by CSA Laboratories:
Certified for 150 PSI maximum working pressure. |
|||||||||
Warranty |
N/A
|
|||||||||
Note |
N/A
FVIR Compliant. Side taps. Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. |
N/A
FVIR Compliant. Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. |
N/A
FVIR Compliant. Side taps. Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. |
N/A
FVIR Compliant. Side taps. Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. |
N/A
FVIR Compliant. Side taps. Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. |
|||||
|