Print Back
Designed for use as a recovery heater having its own storage tank or booster for supplying sanitizing rinse water for dishwashing.
Unit of Measure

Specifications

Manufacturer

N/A A. O. Smith®

Input Power

N/A 45 kW153585 BTU/hr

Number of Elements

N/A 9

Element Power

N/A 5000 W

Tank Capacity

N/A 50 gal189 L

Equipment Grade

N/A Commercial

Inlet/Outlet (NPT)

N/A 1-1/4 in3.2 cm

Approximate Shipping Weight

N/A 265 lb120 kg

Heating Source

N/A Electric

Industry Standards

N/A ASHRAE/IESNA 90.1 ASME Certified

Electrical Characteristics

Full Load Current Single Phase 208 V

N/A 216.3 A

Full Load Current Single Phase 240 V

N/A 187.5 A

Full Load Current Single Phase 277 V

N/A 162.5 A

Full Load Current Single Phase 480 V

N/A 93.8 A

Full Load Current Three Phase 208 V

N/A 124.9 A

Full Load Current Three Phase 240 V

N/A 108.3 A

Full Load Current Three Phase 480 V

N/A 54.1 A

Standard Voltage

N/A 208 V240 V480 V

Phase

N/A Single Three

Dimensions

Schematic

N/A
Schematic Drawing for Gold Xi™ DVE Series Commercial Electric Water Heaters

Dimension A

N/A 55-3/4 in142 cm

Dimension B

N/A 21-3/4 in55.2 cm

Dimension C

N/A 27 in68.6 cm

Maximum Recovery (ºF)

Recovery at 30 ºF Temperature Rise

N/A 615 gal/h

Recovery at 40 ºF Temperature Rise

N/A 461 gal/h

Recovery at 50 ºF Temperature Rise

N/A 369 gal/h

Recovery at 60 ºF Temperature Rise

N/A 307 gal/h

Recovery at 70 ºF Temperature Rise

N/A 263 gal/h

Recovery at 80 ºF Temperature Rise

N/A 230 gal/h

Recovery at 90 ºF Temperature Rise

N/A 205 gal/h

Recovery at 100 ºF Temperature Rise

N/A 184 gal/h

Recovery at 110 ºF Temperature Rise

N/A 168 gal/h

Recovery at 120 ºF Temperature Rise

N/A 154 gal/h

Recovery at 130 ºF Temperature Rise

N/A 142 gal/h

Recovery at 140 ºF Temperature Rise

N/A 132 gal/h

Maximum Recovery (ºC)

Recovery at 17 ºC Temperature Rise

N/A 2326 L/h

Recovery at 22 ºC Temperature Rise

N/A 1745 L/h

Recovery at 28 ºC Temperature Rise

N/A 1398 L/h

Recovery at 33 ºC Temperature Rise

N/A 1163 L/h

Recovery at 39 ºC Temperature Rise

N/A 997 L/h

Recovery at 45 ºC Temperature Rise

N/A 872 L/h

Recovery at 50 ºC Temperature Rise

N/A 755 L/h

Recovery at 56 ºC Temperature Rise

N/A 698 L/h

Recovery at 61 ºC Temperature Rise

N/A 634 L/h

Recovery at 67 ºC Temperature Rise

N/A 582 L/h

Recovery at 72 ºC Temperature Rise

N/A 537 L/h

Recovery at 78 ºC Temperature Rise

N/A 498 L/h

Testing and Certifications

Testing and Certifications

N/A Meets the thermal efficiency and or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ISENA 90.1.

iCOMM™ Compatible.

Options

Options

N/A Manifold Kits with Isolation Valves - Available for multiple installations. Two heaters #9003429205. Three heaters #9003430205. Four heaters #9003431205.

International Voltages - 220, 380, 400, 415, 480, 575, and 600 volts three-phase available with Y connected elements.

Warranty

Warranty

N/A
  • 3-Year Limited Tank Warranty.