Print Back
Unit of Measure

Specifications

Manufacturer

N/A Bradford White®

Capacity

N/A 98 U.S. gal82 Imp. gal371 L

Input Power

N/A 250000 BTU/hr73.2 kW

Water Connection

N/A 1-1/2 in38 mm

Gas Connection Diameter

N/A 3/4 in19 mm

Relief Valve Opening

N/A 1 in25 mm

Standard Approximate Shipping Weight

N/A 610 lb277 kg

ASME Approximate Shipping Weight

N/A 690 lb313 kg

Model Type

N/A Low NOx Compliance

Type

N/A Natural Gas

Style

N/A Flue Damper Millivolt Ignition

Size

N/A C

Test Pressure

N/A 300 psi2068 kPa

Working Pressure

N/A 150 psi1034 kPa

Industry Standards

N/A AHRI Certified® ASME Certified CSA® Certified NSF

Maximum Recovery

Recovery at 40 ºF Degree Rise

N/A 606 gal/h

Recovery at 22 ºC Degree Rise

N/A 2294 L/h

Recovery at 100 ºF Degree Rise

N/A 242 gal/h

Recovery at 56 ºC Degree Rise

N/A 916 L/h

Recovery at 140 ºF Degree Rise

N/A 173 gal/h

Recovery at 78 ºC Degree Rise

N/A 655 L/h

Dimensions

Schematic

N/A
Schematic Drawing for Commercial Flue Damper Millivolt-Powered Energy Saver Gas Water Heaters

Top Vent Height A

N/A 83-3/8 in2118 mm

Jacket Diameter B

N/A 28-1/4 in718 mm

Vent Diameter C

N/A 6 in152 mm

Front Hot Water Connection D

N/A 67 in1702 mm

Floor to Gas Connection E

N/A 4-3/4 in121 mm

Front Cold Water Connection F

N/A 19-1/2 in495 mm

Floor to Top of Heater H

N/A 75-1/2 in1818 mm

Floor to Top Water Connection J

N/A 77-1/4 in1962 mm

General Information

General Information

N/A All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Features

Features

N/A The Commercial Flue Damper Models feature:
  • Automatic Flue Damper - Reduces stand-by loss, saving gas consumption and improving overall efficiency.
  • Hand Hole Cleanout - Allows inspection of the tank interior and facilitates the removal of sediment deposits.
  • Millivolt-Powered Control - No external electrical source is required for operation. An adjustable thermostat can be set up to 180 ºF (82 ºC).
  • Factory Installed Hydrojet® Sediment Reduction System - Cold water inlet sediment reducing device helps prevent sediment build up in the tank.
  • Vitraglas® Lining - Bradford White tanks are lined with an exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600 ºF (871 ºC).
  • Water Connections - Factory installed true dielectric waterway fittings extend heater life and ease installation. Multiple water connection locations allow for greater installation flexibility.
  • E.C.O. - An automatic re-set Energy Cut Off (E.C.O.) shuts off all gas in the event of an overheat condition. This automatically resets when operation conditions are back to normal.
  • Non-CFC Foam Insulation - Covers the sides and top of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
  • Magnesium Anode Rods - Provide added protection against corrosion for long trouble-free service.
  • Sanitizing Capability - Temperature setting up to 180 ºF (82 ºC).
  • Low NOx Construction Available.
  • T&P Relief Valve - Installed.
  • Low Restriction Brass Drain Valve - Durable tamper proof design.
  • NSF construction available.
  • North Carolina Code Compliant.
  • ASME code available on all models above 200,000 BTU/Hr.

Warranty

Warranty

N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.

Note

Note

N/A ASME Code Available.

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed.