Print Back
All commercial electric units have a Fused Ceramic Shield applied under pressure and fired at 1600 ºF to completely cover the tank interior. This provides a tough interior surface for storage tanks and maximum protection against the wearing effects of high-volume and high-temperature water.
Commercial Electric Water Heaters
Unit of Measure
Items Commercial Electric Water Heaters
LDCE32-30H-1500W
Commercial Electric Water Heaters
Commercial Electric Water Heaters
LDCE32-30H-2000W
Commercial Electric Water Heaters
Commercial Electric Water Heaters
LDCE32-30H-2500W
Commercial Electric Water Heaters
Commercial Electric Water Heaters
LDCE32-30H-3000W
Commercial Electric Water Heaters
Commercial Electric Water Heaters
LDCE32-30H-3500W
Commercial Electric Water Heaters
Manufacturer N/A American® Water Heater Company
Capacity N/A 30 gal
Schematic N/A
Schematic Drawing for Commercial Electric Water Heaters
Jacket Diameter A N/A 18 in
Height to Top of Heater B N/A 45-1/4 in
Height to Side T and P Opening C N/A 38-1/2 in
Standard Voltage N/A 240 V
Standard Input Power N/A 4.5 kW
Maximum Input Power N/A 12 kW
Element Power N/A 1500 W N/A 2000 W N/A 2500 W N/A 3000 W N/A 3500 W
Recovery at 40 ºF Temperature Rise N/A N/A N/A N/A 31 gal/h N/A 36 gal/h
Recovery at 50 ºF Temperature Rise N/A N/A N/A N/A 25 gal/h N/A 29 gal/h
Recovery at 60 ºF Temperature Rise N/A N/A N/A N/A 20 gal/h N/A 24 gal/h
Recovery at 70 ºF Temperature Rise N/A N/A N/A N/A 18 gal/h N/A 20 gal/h
Recovery at 80 ºF Temperature Rise N/A N/A N/A N/A 15 gal/h N/A 18 gal/h
Recovery at 90 ºF Temperature Rise N/A N/A N/A N/A 14 gal/h N/A 16 gal/h
Recovery at 100 ºF Temperature Rise N/A N/A N/A N/A 12 gal/h N/A 14 gal/h
Full Load Current Single Phase 120 V N/A 12.5 A N/A 16.7 A N/A 20.8 A N/A 25 A N/A
Full Load Current Single Phase 208 V N/A 7.2 A N/A 9.6 A N/A 12 A N/A 14.4 A N/A 16.8 A
Full Load Current Single Phase 240 V N/A 6.3 A N/A 8.3 A N/A 10.4 A N/A 12.5 A N/A 14.6 A
Full Load Current Single Phase 277 V N/A 5.4 A N/A 7.2 A N/A 9 A N/A 10.8 A N/A 12.6 A
Full Load Current Single Phase 480 V N/A 3.1 A N/A 4.2 A N/A 5.2 A N/A 6.3 A N/A 7.3 A
Full Load Current Three Phase 208 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 14.4 A N/A 19.2 A
Full Load Current Three Phase 240 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 12.5 A N/A 16.7 A
Full Load Current Three Phase 480 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 6.3 A N/A 8.3 A
Full Load Current Three Phase 208 V (Terminal L3) N/A N/A N/A N/A 25 A N/A 33.3 A
Full Load Current Three Phase 240 V (Terminal L3) N/A N/A N/A N/A 21.7 A N/A 28.9 A
Full Load Current Three Phase 480 V (Terminal L3) N/A N/A N/A N/A 10.8 A N/A 14.4 A
Full Load Current Three Phase 208 V (Terminal L1 and L2) N/A N/A N/A N/A 14.4 A N/A 19.2 A
Full Load Current Three Phase 240 V (Terminal L1 and L2) N/A N/A N/A N/A 12.5 A N/A 16.7 A
Full Load Current Three Phase 480 V (Terminal L1 and L2) N/A N/A N/A N/A 6.3 A N/A 8.3 A
Operation Type N/A N/A N/A N/A Interlocking Operation Simultaneous Operation N/A
Voltage N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 208 V240 V277 V480 V N/A 208 V240 V277 V480 V
Phase N/A Single N/A Single N/A Single N/A Single Three N/A Single
Water Connection N/A 3/4 in
Style N/A Standard
Size N/A C
Type N/A Electric
Industry Standards N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed
Features N/A
  • "Environmentally-Friendly" Non-CFC Insulation.
    Foam insulation traps heat within the tank, saving energy.
  • Combination Surface-Mounted Thermostats with High Limits.
    Adjustable to 170 ºF. One thermostat provided for each element. High limit factory set at 190 ºF.
  • Anode Rod.
    Promotes longer tank life through protection against corrosion of tank interior.
  • Incoloy Screw-In Elements.
    For ease of service and long life.
  • Wattages from 3 kW to 12 kW.
  • 208, 240, 277, 480 Voltages Available.
  • UL® Listed.
  • Non-Metallic, Corrosion-free Durable, Brass Drain Valve.
  • Interlocking or Simultaneous Element Wiring.
  • Single-Phase or Unbalanced Three-Phase Operation Available (277 volt, single phase only).
  • Dip Tube
    Carries cold inlet water deep into the tank to minimize temperature dilution of hot water.
  • 3/4" Water Connections
    Located on top.
Warranty N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.
Note N/A Limited warranty on tank and parts. Complete details in manual. Specify wattage, voltage and phase when ordering.