Print Back
American Standard® Commercial Water Heaters
Unit of Measure
Items Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
75-76-AS
Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heater
Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
75-76-AS-LP
Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heater
Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
N-75-76-AS
Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heater
Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heaters
D-75-399-ASME
Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heater
Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heaters
D-75-399-AS-LP
Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heater
Manufacturer N/A American Standard®
Tank Capacity N/A 75 gal
Input Power N/A 76100 BTU N/A 76100 BTU N/A 76100 BTU N/A 399900 BTU N/A 399900 BTU
Type N/A Natural Gas N/A Liquid Propane Gas N/A Natural Gas N/A Natural Gas N/A Liquid Propane Gas
Model Type N/A N/A N/A SCAQMD Low NOx N/A N/A
Thermal Efficiency N/A 80 % N/A 80 % N/A 80 % N/A 81 % N/A 81 %
Schematic N/A
Schematic Drawing for Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
N/A
Schematic Drawing for Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
N/A
Schematic Drawing for Model 75-76-AS 75 Gallon (gal) Light Duty Storage Commercial Gas Water Heaters
N/A
Schematic Drawing for Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heaters
N/A
Schematic Drawing for Model D-75-399-AS 75 Gallon (gal) Heavy Duty Instantaneous Direct Spark Ignition Dampered Commercial Gas Water Heaters
Exterior Dimension A N/A 66-3/4 in N/A 66-3/4 in N/A 66-3/4 in N/A 75-3/4 in N/A 75-3/4 in
Exterior Dimension B N/A 26-1/4 in N/A 26-1/4 in N/A 26-1/4 in N/A 30-1/4 in N/A 30-1/4 in
Exterior Dimension C N/A 64-1/2 in N/A 64-1/2 in N/A 64-1/2 in N/A 66-1/4 in N/A 66-1/4 in
Vent Size N/A 4 in N/A 4 in N/A 4 in N/A 8 in N/A 8 in
Top Pipe Size N/A 1-1/2 in N/A 1-1/2 in N/A 1-1/2 in N/A N/A
Rear and Front Water Connection N/A N/A N/A N/A 2 in N/A 2 in
Height to Top Water I.P.S. Connection D N/A 66-3/4 in N/A 66-3/4 in N/A 66-3/4 in N/A N/A
Top Spread Water I.P.S. Connection E N/A 16 in N/A 16 in N/A 16 in N/A N/A
Height to Rear and Front Hot Water I.P.S. Connection F N/A N/A N/A N/A 57 in N/A 57 in
Height to Rear and Front Cold Water I.P.S. Connection G N/A N/A N/A N/A 19-1/4 in N/A 19-1/4 in
Gas I.P.S. Connection Height F N/A 18 in N/A 18 in N/A 18 in N/A N/A
Height to T and P Opening G N/A 56-1/2 in N/A 56-1/2 in N/A 56-1/2 in N/A N/A
Gas I.P.S. Connection Height H N/A N/A N/A N/A 4-3/4 in N/A 4-3/4 in
Gas I.P.S. Connection Size N/A 1/2 in N/A 1/2 in N/A 1/2 in N/A 3/4 in N/A 3/4 in
Height to T and P Opening J N/A N/A N/A N/A 58-1/4 in N/A 58-1/4 in
T and P Opening N/A 3/4 in N/A 3/4 in N/A 3/4 in N/A 1 in N/A 1 in
Recovery at 40 ºF Temperature Rise N/A 185 gal/h N/A 185 gal/h N/A 185 gal/h N/A 982 gal/h N/A 982 gal/h
Recovery at 50 ºF Temperature Rise N/A 148 gal/h N/A 148 gal/h N/A 148 gal/h N/A 785 gal/h N/A 785 gal/h
Recovery at 60 ºF Temperature Rise N/A 123 gal/h N/A 123 gal/h N/A 123 gal/h N/A 654 gal/h N/A 654 gal/h
Recovery at 70 ºF Temperature Rise N/A 105 gal/h N/A 105 gal/h N/A 105 gal/h N/A 561 gal/h N/A 561 gal/h
Recovery at 80 ºF Temperature Rise N/A 92 gal/h N/A 92 gal/h N/A 92 gal/h N/A 491 gal/h N/A 491 gal/h
Recovery at 90 ºF Temperature Rise N/A 82 gal/h N/A 82 gal/h N/A 82 gal/h N/A 436 gal/h N/A 436 gal/h
Recovery at 100 ºF Temperature Rise N/A 74 gal/h N/A 74 gal/h N/A 74 gal/h N/A 393 gal/h N/A 393 gal/h
Recovery at 110 ºF Temperature Rise N/A 67 gal/h N/A 67 gal/h N/A 67 gal/h N/A 357 gal/h N/A 357 gal/h
Recovery at 120 ºF Temperature Rise N/A 62 gal/h N/A 62 gal/h N/A 62 gal/h N/A 327 gal/h N/A 327 gal/h
Recovery at 130 ºF Temperature Rise N/A 57 gal/h N/A 57 gal/h N/A 57 gal/h N/A 302 gal/h N/A 302 gal/h
Recovery at 140 ºF Temperature Rise N/A 53 gal/h N/A 53 gal/h N/A 53 gal/h N/A 280 gal/h N/A 280 gal/h
Storage Capacity N/A 75 U.S. gal
One Hour Recovery at 100 ºF Temperature Rise N/A 74 gal/h N/A 74 gal/h N/A 74 gal/h N/A 393 gal/h N/A 393 gal/h
Maximum Hot Water Delivery (1 Hour) N/A 127 L N/A 127 L N/A 127 L N/A 446 L N/A 446 L
Maximum Hot Water Delivery (2 Hours) N/A 201 L N/A 201 L N/A 201 L N/A 839 L N/A 839 L
Maximum Hot Water Delivery (3 Hours) N/A 275 L N/A 275 L N/A 275 L N/A 1232 L N/A 1232 L
Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise N/A 1.2 g/min N/A 1.2 g/min N/A 1.2 g/min N/A 6.6 g/min N/A 6.6 g/min
AC Voltage N/A N/A N/A N/A 120 V N/A 120 V
Frequency N/A N/A N/A N/A 60 Hz N/A 60 Hz
Current N/A N/A N/A N/A <5 A N/A <5 A
Size N/A C
Test Pressure N/A 300 psi
Working Pressure N/A 150 psi
Industry Standards N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 NSF N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 NSF N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 NSF N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 1992 90.1b ASME Certified NSF N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 1992 90.1b NSF
Testing and Certifications N/A
  • American Standard® gas water heaters are certified at 300 PSI test pressure and for 150 PSI working pressure
  • Tested and listed with CSA® International in accordance with ANSI Z21.10.3 - CSA® 4.3 for up to 180 ºF operation as an automatic storage and/or automatic circulating tank heater. ASHRAE Standard 90.1 1999 addendum 90.1b. CSA® certified to meet NSF/ANSI 5 Standards
N/A
  • American Standard® gas water heaters are certified at 300 PSI test pressure and for 150 PSI working pressure
  • Tested and listed with CSA® International in accordance with ANSI Z21.10.3 - CSA® 4.3 for up to 180 ºF operation as an automatic storage and/or automatic circulating tank heater. ASHRAE Standard 90.1 1999 addendum 90.1b. CSA® certified to meet NSF/ANSI 5 Standards
N/A
  • American Standard® gas water heaters are certified at 300 PSI test pressure and for 150 PSI working pressure
  • Tested and listed with CSA® International in accordance with ANSI Z21.10.3 - CSA® 4.3 for up to 180 ºF operation as an automatic storage and/or automatic circulating tank heater. ASHRAE Standard 90.1 1999 addendum 90.1b. CSA® certified to meet NSF/ANSI 5 Standards
N/A
  • American Standard® gas water heaters are certified at 300 PSI test pressure and for 150 PSI working pressure. All tanks are hydrostatically tested at the factory
  • Tested and listed with CSA® International in accordance with ANSI Z21.10.3 CSA® 4.3 for up to 180 ºF operation as an instantaneous and/or automatic circulating tank heater. Meets ASHRAE 1992 90.1b
N/A
  • American Standard® gas water heaters are certified at 300 PSI test pressure and for 150 PSI working pressure. All tanks are hydrostatically tested at the factory
  • Tested and listed with CSA® International in accordance with ANSI Z21.10.3 CSA® 4.3 for up to 180 ºF operation as an instantaneous and/or automatic circulating tank heater. Meets ASHRAE 1992 90.1b
Features N/A
  • Heavy Gauge Steel Tank for extra years of trouble-free service.
  • Inner tank glass-lined with Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • R-16.7 non-CFC foam insulated to save energy and reduce fuel costs by maximizing heat retention.
  • Two anode rods to prolong tank life.
  • Self-Cleaning turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Full size hand-hole cleanout for eased tank inspection and/or removal of sediment deposits.
  • Furnished with four heavy gauge steel legs designed to maximize durability and afford rock-steady installation.
  • Automatic non-electric gas thermostat adjustable to 180 ºF. When installed with a mixing valve, the 75-76-AS can deliver 180 ºF sanitizing and 140 ºF general purpose hot water simultaneously.
  • Hinged with knob outside access combustion chamber door and sliding inner door to sequester burner and pilot area for added safety.
  • Factory installed energy cut-off system and pressure/temperature relief valve.
  • Small vent size and top mount 1-1/2" water connections to afford universal replacement of other brands.
  • All tanks are hydrostatically tested at the factory.
N/A
  • Heavy Gauge Steel Tank for extra years of trouble-free service.
  • Inner tank glass-lined with Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • R-16.7 non-CFC foam insulated to save energy and reduce fuel costs by maximizing heat retention.
  • Two anode rods to prolong tank life.
  • Self-Cleaning turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Full size hand-hole cleanout for eased tank inspection and/or removal of sediment deposits.
  • Furnished with four heavy gauge steel legs designed to maximize durability and afford rock-steady installation.
  • Automatic non-electric gas thermostat adjustable to 180 ºF. When installed with a mixing valve, the 75-76-AS can deliver 180 ºF sanitizing and 140 ºF general purpose hot water simultaneously.
  • Hinged with knob outside access combustion chamber door and sliding inner door to sequester burner and pilot area for added safety.
  • Factory installed energy cut-off system and pressure/temperature relief valve.
  • Small vent size and top mount 1-1/2" water connections to afford universal replacement of other brands.
  • All tanks are hydrostatically tested at the factory.
N/A
  • Heavy Gauge Steel Tank for extra years of trouble-free service.
  • Inner tank glass-lined with Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • R-16.7 non-CFC foam insulated to save energy and reduce fuel costs by maximizing heat retention.
  • Two anode rods to prolong tank life.
  • Self-Cleaning turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Full size hand-hole cleanout for eased tank inspection and/or removal of sediment deposits.
  • Furnished with four heavy gauge steel legs designed to maximize durability and afford rock-steady installation.
  • Automatic non-electric gas thermostat adjustable to 180 ºF. When installed with a mixing valve, the 75-76-AS can deliver 180 ºF sanitizing and 140 ºF general purpose hot water simultaneously.
  • Hinged with knob outside access combustion chamber door and sliding inner door to sequester burner and pilot area for added safety.
  • Factory installed energy cut-off system and pressure/temperature relief valve.
  • Small vent size and top mount 1-1/2" water connections to afford universal replacement of other brands.
  • All tanks are hydrostatically tested at the factory.
N/A
  • Heavy Gauge Steel Tank utilizes only twelve internal flue tubes resulting in fewer critical welds to yield added years of trouble-free service.
  • ASME Construction Model available.
  • Inner tank glass-lined with Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • R-8.3 non-CFC foam insulated to save energy and reduce fuel costs by maximizing heat retention.
  • Four anode rods to prolong tank life.
  • Self-Cleaning turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Full size hand-hole cleanout for eased tank inspection and/or removal of sediment deposits.
  • Electronic direct-spark ignition system saves fuel by eliminating the need for a standby gas pilot.
  • Automatic motorized flue damper reduces tank heat loss during standby periods for lowest operating costs.
  • Fully adjustable 24-volt controls provide temperature settings to 180 ºF. When installed with a mixing valve, the D-75-399-AS can deliver 180 ºF sanitizing and 140 ºF general purpose hot water simultaneously.
  • Factory installed energy cut-off system and pressure/temperature relief valve.
  • Two inch rear and front water connections for simplified replacement of similar units, connection to circulating lines and eased multiple heater or storage tank installations. CSA® certified to meet NSF/ANSI 5 Standards.
N/A
  • Heavy Gauge Steel Tank utilizes only twelve internal flue tubes resulting in fewer critical welds to yield added years of trouble-free service.
  • ASME Construction Model available.
  • Inner tank glass-lined with Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • R-8.3 non-CFC foam insulated to save energy and reduce fuel costs by maximizing heat retention.
  • Four anode rods to prolong tank life.
  • Self-Cleaning turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Full size hand-hole cleanout for eased tank inspection and/or removal of sediment deposits.
  • Electronic direct-spark ignition system saves fuel by eliminating the need for a standby gas pilot.
  • Automatic motorized flue damper reduces tank heat loss during standby periods for lowest operating costs.
  • Fully adjustable 24-volt controls provide temperature settings to 180 ºF. When installed with a mixing valve, the D-75-399-AS can deliver 180 ºF sanitizing and 140 ºF general purpose hot water simultaneously.
  • Factory installed energy cut-off system and pressure/temperature relief valve.
  • Two inch rear and front water connections for simplified replacement of similar units, connection to circulating lines and eased multiple heater or storage tank installations. CSA® certified to meet NSF/ANSI 5 Standards.
Warranty N/A
  • 3-Year Limited Warranty - On Inner Glass-Lined Tank.
  • 1-Year Limited Warranty - On all Other Component Parts.
Note N/A This water heater meets the requirements of ASHRAE and meets or exceeds the thermal efficiency requirements of california and other states recognizing ASHRAE.

Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.
N/A This water heater meets the requirements of ASHRAE and meets or exceeds the thermal efficiency requirements of california and other states recognizing ASHRAE.

Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.
N/A This water heater meets the requirements of ASHRAE and meets or exceeds the thermal efficiency requirements of california and other states recognizing ASHRAE.

Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.
N/A This water heater meets the requirements of ASHRAE 1992 standard addendum 90.1b and meets or exceeds the thermal efficiency and standby loss requirements of california and other states recognizing ASHRAE.

Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANZI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.
N/A This water heater meets the requirements of ASHRAE 1992 standard addendum 90.1b and meets or exceeds the thermal efficiency and standby loss requirements of california and other states recognizing ASHRAE.

Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANZI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice.