Print Back
Designed for use as a recovery heater having its own storage tank or booster for supplying sanitizing rinse water for dishwashing.
Unit of Measure

Specifications

Manufacturer

N/A A. O. Smith®

Input Power

N/A 15 kW51195 BTU/hr

Number of Elements

N/A 3

Element Power

N/A 5000 W

Tank Capacity

N/A 119 gal450 L

Equipment Grade

N/A Commercial

Inlet/Outlet (NPT)

N/A 1-1/4 in3.2 cm

Approximate Shipping Weight

N/A 390 lb117 kg

Heating Source

N/A Electric

Industry Standards

N/A ASHRAE/IESNA 90.1 ASME Certified

Electrical Characteristics

Full Load Current Single Phase 208 V

N/A 72.1 A

Full Load Current Single Phase 240 V

N/A 62.5 A

Full Load Current Single Phase 277 V

N/A 54.2 A

Full Load Current Single Phase 480 V

N/A 31.3 A

Full Load Current Three Phase 208 V

N/A 41.6 A

Full Load Current Three Phase 240 V

N/A 36.1 A

Full Load Current Three Phase 480 V

N/A 18.0 A

Standard Voltage

N/A 208 V240 V480 V

Phase

N/A Single Three

Dimensions

Schematic

N/A
Schematic Drawing for Gold Xi™ DVE Series Commercial Electric Water Heaters

Dimension A

N/A 62-1/4 in158.1 cm

Dimension B

N/A 29-1/2 in75 cm

Dimension C

N/A 35 in88.9 cm

Maximum Recovery (ºF)

Recovery at 30 ºF Temperature Rise

N/A 205 gal/h

Recovery at 40 ºF Temperature Rise

N/A 154 gal/h

Recovery at 50 ºF Temperature Rise

N/A 123 gal/h

Recovery at 60 ºF Temperature Rise

N/A 102 gal/h

Recovery at 70 ºF Temperature Rise

N/A 88 gal/h

Recovery at 80 ºF Temperature Rise

N/A 77 gal/h

Recovery at 90 ºF Temperature Rise

N/A 68 gal/h

Recovery at 100 ºF Temperature Rise

N/A 61 gal/h

Recovery at 110 ºF Temperature Rise

N/A 56 gal/h

Recovery at 120 ºF Temperature Rise

N/A 51 gal/h

Recovery at 130 ºF Temperature Rise

N/A 47 gal/h

Recovery at 140 ºF Temperature Rise

N/A 44 gal/h

Maximum Recovery (ºC)

Recovery at 17 ºC Temperature Rise

N/A 775 L/h

Recovery at 22 ºC Temperature Rise

N/A 582 L/h

Recovery at 28 ºC Temperature Rise

N/A 465 L/h

Recovery at 33 ºC Temperature Rise

N/A 388 L/h

Recovery at 39 ºC Temperature Rise

N/A 332 L/h

Recovery at 45 ºC Temperature Rise

N/A 291 L/h

Recovery at 50 ºC Temperature Rise

N/A 258 L/h

Recovery at 56 ºC Temperature Rise

N/A 233 L/h

Recovery at 61 ºC Temperature Rise

N/A 211 L/h

Recovery at 67 ºC Temperature Rise

N/A 194 L/h

Recovery at 72 ºC Temperature Rise

N/A 149 L/h

Recovery at 78 ºC Temperature Rise

N/A 166 L/h

Testing and Certifications

Testing and Certifications

N/A Meets the thermal efficiency and or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ISENA 90.1.

iCOMM™ Compatible.

Options

Options

N/A Manifold Kits with Isolation Valves - Available for multiple installations. Two heaters #9003429205. Three heaters #9003430205. Four heaters #9003431205.

International Voltages - 220, 380, 400, 415, 480, 575, and 600 volts three-phase available with Y connected elements.

Warranty

Warranty

N/A
  • 3-Year Limited Tank Warranty.