Manufacturer |
N/A American® Water Heater Company |
Capacity |
N/A 34 gal |
Input Power |
N/A 150000 BTU/hr |
Thermal Efficiency |
N/A 95 % |
Approximate Shipping Weight |
N/A 150 lb |
Tank |
N/A Stainless Steel |
Diameter |
N/A 22 in |
Minimum Approximate Installed Height |
N/A 67 in |
Side Wall Vent Option |
N/A Standard |
Vent Type |
N/A ABS CPVC Plastic PVC |
Sealed Combustion |
N/A Yes |
Self-Diagnostic Control |
N/A Yes |
Resists Negative Building Pressure |
N/A Yes |
Maximum Temperature Setting |
N/A 185 ºF |
Insulation Thickness |
N/A 2 in |
Low NOx |
N/A Standard |
Style |
N/A Polaris® High Efficiency |
Size |
N/A C |
Type |
N/A Liquid Propane Gas |
Industry Standards |
N/A ANSI Standards Z-21.10.3 ASHRAE Standards CSA® 4.3 IESNA 90.1 |
Recovery at 40 ºF Temperature Rise |
N/A 432 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 345 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 288 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 247 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 216 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 192 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 173 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 157 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 144 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 133 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 123 gal/h |
First Hour Rating at 40 ºF Temperature Rise |
N/A 459 gal |
First Hour Rating at 50 ºF Temperature Rise |
N/A 373 gal |
First Hour Rating at 60 ºF Temperature Rise |
N/A 315 gal |
First Hour Rating at 70 ºF Temperature Rise |
N/A 274 gal |
First Hour Rating at 80 ºF Temperature Rise |
N/A 243 gal |
First Hour Rating at 90 ºF Temperature Rise |
N/A 219 gal |
First Hour Rating at 100 ºF Temperature Rise |
N/A 200 gal |
First Hour Rating at 110 ºF Temperature Rise |
N/A 184 gal |
First Hour Rating at 120 ºF Temperature Rise |
N/A 171 gal |
First Hour Rating at 130 ºF Temperature Rise |
N/A 160 gal |
First Hour Rating at 140 ºF Temperature Rise |
N/A 151 gal |
Maximum First Hour Recovery and Storage at 40 ºF Temperature Rise |
N/A 7.7 gal/h |
Maximum First Hour Recovery and Storage at 50 ºF Temperature Rise |
N/A 6.2 gal/h |
Maximum First Hour Recovery and Storage at 60 ºF Temperature Rise |
N/A 5.3 gal/h |
Maximum First Hour Recovery and Storage at 70 ºF Temperature Rise |
N/A 4.6 gal/h |
Maximum First Hour Recovery and Storage at 80 ºF Temperature Rise |
N/A 4.1 gal/h |
Maximum First Hour Recovery and Storage at 90 ºF Temperature Rise |
N/A 3.7 gal/h |
Maximum First Hour Recovery and Storage at 100 ºF Temperature Rise |
N/A 3.3 gal/h |
Maximum First Hour Recovery and Storage at 110 ºF Temperature Rise |
N/A 3.1 gal/h |
Maximum First Hour Recovery and Storage at 120 ºF Temperature Rise |
N/A 2.9 gal/h |
Maximum First Hour Recovery and Storage at 130 ºF Temperature Rise |
N/A 2.7 gal/h |
Maximum First Hour Recovery and Storage at 140 ºF Temperature Rise |
N/A 2.5 gal/h |
Maximum Recovery at 40 ºF Temperature Rise (Continuous Operation) |
N/A 7.2 gpm |
Maximum Recovery at 50 ºF Temperature Rise (Continuous Operation) |
N/A 5.8 gpm |
Maximum Recovery at 60 ºF Temperature Rise (Continuous Operation) |
N/A 4.8 gpm |
Maximum Recovery at 70 ºF Temperature Rise (Continuous Operation) |
N/A 4.1 gpm |
Maximum Recovery at 80 ºF Temperature Rise (Continuous Operation) |
N/A 3.6 gpm |
Maximum Recovery at 90 ºF Temperature Rise (Continuous Operation) |
N/A 3.2 gpm |
Maximum Recovery at 100 ºF Temperature Rise (Continuous Operation) |
N/A 2.9 gpm |
Maximum Recovery at 110 ºF Temperature Rise (Continuous Operation) |
N/A 2.6 gpm |
Maximum Recovery at 120 ºF Temperature Rise (Continuous Operation) |
N/A 2.4 gpm |
Maximum Recovery at 130 ºF Temperature Rise (Continuous Operation) |
N/A 2.2 gpm |
Maximum Recovery at 140 ºF Temperature Rise (Continuous Operation) |
N/A 2.1 gpm |
General Information |
N/A
Up to 96% Efficient
An ultra quiet radial blower is combined with a submerged burner for whisper quiet operation. Indicator lights illuminate when the power is on and when the igniter and burner are operating. |
Woven Metal Burner |
N/A
|
Whisper Quiet Blower |
N/A A high capacity, quiet, brushless, DC motor is combined with an integrated gas/air control safety system resulting in excellent combustion with flexible venting options. |
Easy to Install and Service |
N/A
|
Features |
N/A
|
Other Features |
N/A
|
Note |
N/A
This water heater design has been tested by CSA International and complies with ANSI Z21.10.1, Section 2.35 Flammable Vapor Resistance 3" Concentric Vent Part «6911089 of 2" Concentric Vent Part »6911088. Specification are subject to change without notice In accordance with our policy of continuous improvement. Input output and recovery may vary depending upon air inlet and exhaust outlet Installations. Length and number of bends In Inlet and outlet pipes may reduce Input and output.1/2" gas supply line can be used for up to 150,000 BTU units; units over 150,000 BTU's require a 3/4" gas supply line. All installations are one or two temperature, with or without recirculation. |