Manufacturer |
N/A Bradford White® |
Standard Type |
N/A Non-ASME |
Capacity |
N/A 100 U.S. gal83 Imp. gal379 L |
Input Power |
N/A 300000 BTU/hr87.9 kW·h |
First Hour Delivery at 100 ºF Temperature Rise |
N/A 405 gal |
Water Connection Diameter |
N/A 1-1/2 in38 mm |
Gas Connection Diameter |
N/A 3/4 in19 mm |
Relief Valve Opening |
N/A 1 in25 mm |
Approximate Shipping Weight |
N/A 900 lb408 kg |
Type |
N/A Natural Gas |
Style |
N/A Ultra-High Efficiency |
Size |
N/A C |
Test Pressure |
N/A 300 psi2068 kPa |
Working Pressure |
N/A 150 psi1034 kPa |
Industry Standards |
N/A AHRI Certified® ASME Certified CSA® Certified NSF |
Maximum Intake Length for 3" Vent Pipe (Power Direct Vent) |
N/A 30 ft |
Maximum Exhaust Length for 3" Vent Pipe (Power Direct Vent) |
N/A 30 ft |
Maximum Exhaust Length for 3" Vent Pipe (Power Vent) |
N/A 60 ft |
Maximum Intake Length for 4" Vent Pipe (Power Direct Vent) |
N/A 55 ft |
Maximum Exhaust Length for 4" Vent Pipe (Power Direct Vent) |
N/A 55 ft |
Maximum Exhaust Length for 4" Vent Pipe (Power Vent) |
N/A 110 ft |
Recovery at 40 ºF Degree Rise |
N/A 836 gal/h |
Recovery at 22 ºC Degree Rise |
N/A 3165 L/h |
Recovery at 100 ºF Degree Rise |
N/A 335 gal/h |
Recovery at 56 ºC Degree Rise |
N/A 1268 L/h |
Recovery at 140 ºF Degree Rise |
N/A 239 gal/h |
Recovery at 78 ºC Degree Rise |
N/A 905 L/h |
Thermal Efficiency |
N/A 92 % |
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. |
Optional Equipment Features |
N/A
Maxitrol Gas Pressure Regulating valve - Ensures proper supply pressure to eF unit of 7" to 11" W.C. (provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. NSF Compliance Kit - p/n 265-44542-04. Low Gas Inlet Pressure Option - Pre-assembled to allow operation at lower inlet natural gas pressure (Down to 3.5" w.c.). |
Additional Equipment Features |
N/A
|
Features |
N/A
|
Note |
N/A
Air intake cannot exceed exhaust by more than 30 ft. in any venting situation. Subtract 5 ft. for each additional 90º elbow. All models comply with the latest ultra-low NOx requirements of 14 ng/J or less. Amp Draw range = 1.0 to 1.8 amps. 14.0" w.c. maximum static, 4.5" w.c. minimum running (Recommend 7.0" w.c. minimum running) Concentric Vent Kit Termination - 3" termination fitting provides for only one exit opening through wall or roof (p/n 239-44069-01). Diagrams are for both 60 and 100 gallon models. |