Manufacturer |
N/A Rheem® |
Capacity |
N/A 75 gal284 L |
Input Power |
N/A 70000 BTU/hr |
Type |
N/A Liquid Propane Gas |
Approximate Shipping Weight |
N/A 330 lb150 kg |
Working Pressure |
N/A 150 psi |
Thermal Efficiency |
N/A 80 % |
Style |
N/A Power Vent |
Size |
N/A C |
Industry Standards |
N/A ANSI Z-21.10.1 ASHRAE Standards ASME Certified CSA® Certified |
Recovery at 40 ºF Temperature Rise |
N/A 161 U.S. gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 610 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 129 U.S. gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 489 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 107 U.S. gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 407 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 92 U.S. gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 349 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 81 U.S. gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 305 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 72 U.S. gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 272 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 64 U.S. gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 244 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 59 U.S. gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 222 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 54 U.S. gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 203 L/h |
Maximum Delivery at 100 ºF (5 Minutes) |
N/A 58 U.S. gal |
Maximum Delivery at 55.6 ºC (5 Minutes) |
N/A 219 L |
Maximum Delivery at 100 ºF (10 Minutes) |
N/A 63 U.S. gal |
Maximum Delivery at 55.6 ºC (10 Minutes) |
N/A 239 L |
Maximum Delivery at 100 ºF (15 Minutes) |
N/A 68 U.S. gal |
Maximum Delivery at 55.6 ºC (15 Minutes) |
N/A 259 L |
Maximum Delivery at 100 ºF (20 Minutes) |
N/A 74 U.S. gal |
Maximum Delivery at 55.6 ºC (20 Minutes) |
N/A 279 L |
Maximum Delivery at 100 ºF (30 Minutes) |
N/A 84 U.S. gal |
Maximum Delivery at 55.6 ºC (30 Minutes) |
N/A 319 L |
Maximum Delivery at 100 ºF (45 Minutes) |
N/A 100 U.S. gal |
Maximum Delivery at 55.6 ºC (45 Minutes) |
N/A 380 L |
Maximum Delivery at 100 ºF (60 Minutes) |
N/A 117 U.S. gal |
Maximum Delivery at 55.6 ºC (60 Minutes) |
N/A 443 L |
Maximum Delivery at 100 ºF (120 Minutes) |
N/A 182 U.S. gal |
Maximum Delivery at 55.6 ºC (120 Minutes) |
N/A 687 L |
Maximum Delivery at 100 ºF (180 Minutes) |
N/A 246 U.S. gal |
Maximum Delivery at 55.6 ºC (180 Minutes) |
N/A 932 L |
Minimum to Recovery Contents |
N/A 70 |
Features and Benefits |
N/A
Power Vent commercial gas water heaters are available in 70,000 and 75,000 BTU/hr, with a maximum temperature setting of 160 degrees Fahrenheit and vent up to 95 equivalent feet. This water heater is specifically designed where medium quantities of hot water are required. Typical applications include large residences, small restaurants, apartments up to six units and small office buildings. Thermal Efficiency Meets or exceeds a minimum of 80% (non-condensing). Superior Tank Design Proprietary steel formulation with a unique coat of high temperature porcelain enamel to maximize corrosion resistance. FVIR Compliant Maintenance free with no filter to clean. Flammable Vapor Detection Sensor A protective control system disables the heater in the presence of flammable vapor accumulation. Self-Diagnostic System Integrated self-diagnostic system control takes the guess work away. Integral Automatic Blower The powered blower assists in quietly bringing in combustion air and discharging combustion gases using 110 volt electrical connection. Low Emissions Environmentally friendly burner is 40 ng/J NOx compliant. Easier, Less Costly Venting Installs with PVC, ABS, or CPVC vent options with vertical or horizontal termination. Side connections are available for ease of installation and flexibility. Maximum vent length is 95 equivalent feet using 4" PVC; Vents up to 35 equivalent feet using 3" PVC pipe. For Canadian installations, use ULC- S636 PVC and CPVC pipe. Longer Life A patented magnesium anode rod design with resistor protects the tank from corrosion. Hot Surface Ignition (HSI) Less fuel consumption versus a standing pilot. Self-Cleaning Fights sediment buildup to increase operating efficiency and extend tank life. Full-port, Full-flow Drain Valve Factory installed brass drain valve allows for faster draining and servicing. |
General Information |
N/A
Efficiency These models have been tested according to DOE test procedures, and meet or exceed thermal efficiency and standby loss requirements of current ASHRAE standards (Part of the Federally mandated Energy Policy Act (EPact) and NRCAN). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction Design certified by CSA® Laboratories:
|