Print Back
Universal™ is a family of commercial gas water heaters that are designed to fit into tight retrofit applications.
Unit of Measure

Specifications

Manufacturer

Rheem®

Capacity

35 to 100 gal

Thermal Efficiency

80 %

Input Power

300000 BTU/hr

Tank Capacity

72 gal273 L

Temperature Rise

100 ºF56 ºC

Minimum to Recovery Contents

15

Standard Approximate Shipping Weight

590 lb267 kg

ASME Approximate Shipping Weight

630 lb285 kg

Style

Universal™

Size

C

Type

Liquid Propane Gas Natural Gas

Industry Standards

ANSI ASME Certified C.E.C. Listed CSA® Certified

Maximum Recovery

Recovery at 40 ºF Temperature Rise

727 U.S. gal/h

Recovery at 22 ºC Temperature Rise

2753 L/h

Recovery at 50 ºF Temperature Rise

582 U.S. gal/h

Recovery at 28 ºC Temperature Rise

2202 L/h

Recovery at 60 ºF Temperature Rise

485 U.S. gal/h

Recovery at 33 ºC Temperature Rise

1835 L/h

Recovery at 70 ºF Temperature Rise

416 U.S. gal/h

Recovery at 39 ºC Temperature Rise

1573 L/h

Recovery at 80 ºF Temperature Rise

364 U.S. gal/h

Recovery at 45 ºC Temperature Rise

1376 L/h

Recovery at 90 ºF Temperature Rise

323 U.S. gal/h

Recovery at 50 ºC Temperature Rise

1224 L/h

Recovery at 100 ºF Temperature Rise

291 U.S. gal/h

Recovery at 56 ºC Temperature Rise

1101 L/h

Recovery at 110 ºF Temperature Rise

264 U.S. gal/h

Recovery at 61 ºC Temperature Rise

1001 L/h

Recovery at 120 ºF Temperature Rise

242 U.S. gal/h

Recovery at 67 ºC Temperature Rise

918 L/h

Recovery at 130 ºF Temperature Rise

224 U.S. gal/h

Recovery at 72 ºC Temperature Rise

847 L/h

Recovery at 140 ºF Temperature Rise

208 U.S. gal/h

Recovery at 78 ºC Temperature Rise

787 L/h

Maximum Delivery

Maximum Delivery (5 Minutes)

75 U.S. gal283 L

Maximum Delivery (10 Minutes)

99 U.S. gal374 L

Maximum Delivery (15 Minutes)

123 U.S. gal466 L

Maximum Delivery (20 Minutes)

147 U.S. gal558 L

Maximum Delivery (30 Minutes)

196 U.S. gal741 L

Maximum Delivery (45 Minutes)

269 U.S. gal1017 L

Maximum Delivery (60 Minutes)

341 U.S. gal1292 L

Maximum Delivery (120 Minutes)

632 U.S. gal2393 L

Maximum Delivery (180 Minutes)

923 U.S. gal3494 L

Dimensions

Schematic


Schematic Drawing for Universal™ Commercial Gas Water Heaters

Dimension A

71 in1803 mm

Dimension B

64-1/8 in1629 mm

Dimension C

26-1/4 in667 mm

Dimension D

25 in635 mm

Dimension E

8 in203 mm

Dimension F

58-5/8 in1489 mm

Dimension G

3/4 in19 mm

Dimension H

20 in508 mm

Water Connection

Top Inlet/Outlet Water Connection

1-1/2 in38 mm

Front Side Water Connection

1-1/2 in38 mm

Rear Side Water Connection

1-1/2 in38 mm

Clearances to Combustibles

Side

6 in152 mm

Rear

6 in152 mm

Top

12 in305 mm

Features and Benefits

Features and Benefits

The tighter the commercial retrofit, the more you will appreciate how the Universal™’s compact size and multiple water connections simplify installations. Choose from 80% thermal efficiency models that range from 98,000-399,900 Btu/h and have maximum temperature setting of 180 degrees Fahrenheit.

Space Saver Design
The short heights and narrow jacket diameters, plus the top, front and rear water inlets/outlets offer the ultimate in installation flexibility.

System Sentinel ™ LED Diagnostic System
Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence.

Patented Technology
Universal’s proprietary steel formulation, patented multi-flue design, combined with two coats of porcelain enamel, results in a superior heat exchanger design.

Stainless Steel Burners
Precision burners, raised port design, are formed from high chromium stainless steel. Each burner assembly slides out like a drawer for quick inspection and maintenance.

Low Profile Automatic Flue Damper
Low profile damper minimizes overall product height. Heavy duty vent hood supports are designed to withstand the rigors of installation.

Full-port, Full-flow Drain Valve
Factory installed brass drain valve allows for faster draining and servicing.

Direct Spark-to-Pilot Ignition System
Energy saving ignition that ignites pilot only when there is a call for heat.

Altitude Certifications
Up to 5,000 feet for natural gas and 2,000 feet for LP; with high altitude certification kit, up to 8,000 feet.

Patented Anode Rods
Anode design utilizes multiple magnesium rods to ensure corrosion resistance for a long tank life.

General Information

General Information

Efficiency
All models tested according to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC).

Safety and Construction
Design certified by CSA: For operation at 180 degrees; meets all safety and construction requirement of ANSI Z21.10.3; as an automatic storage or instantaneous water heater; as an automatic circulating tank water heater; and for operation on combustible floors and in alcove installations. Certified for 150 PSI maximum working pressure (160 PSI for ASME models).

Optional Construction
ASME construction is available on designated models. UL Sanitation (NSF5) compliant models are available when equipped with optional seal kit (Part No. AM35450).

CSA/ASME Rated T&P Valve
Factory installed relief valve

Insulation
Sag and moisture proof fiberglass insulation surrounds the storage tank and heavy mineral wool insulation surrounds the combustion chamber.

Hand-hole Cleanout
For easy removal of lime/sediment deposits.

Manual Reset High Limit
ASME models are factory equipped with manual reset high limit to meet the code requirements in many states.

Gas Control System
Thermostat adjusts from 100 to 180 degrees Fahrenheit, 24 volt combination gas valve includes main gas pressure regulation, on-off manual valve, 120/24 volt transformer and high limit temperature cut-out.

Warranty

Warranty

  • 3-Year limited Tank Warranty. Commercial Warranty Certificate for Complete Information.

Note

Note

All Models Require a 120 V Power Source/0.3 amps.

(A) indicates available ASME model.

(A) Suffix Indicates ASME Tank Construction Available.

When ordering ASME construction, place (A) after the model number (for trade reference only)
Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and Pressure Vessel Code, Section IV Part HLW.