Catalog
Unit of Measure
Items
Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters

Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters
Manufacturer N/A American® Water Heater Company
Schematic N/A
Schematic Drawing for Heavy Duty Ultra-Low NOx Commercial Gas Tank-Type Water Heaters
Dimension A N/A 68-1/4 in173.4 cm N/A 68-1/4 in173.4 cm N/A 76 in193 cm N/A 76 in193 cm N/A 76 in193 cm
Dimension B N/A 9-1/2 in24.1 cm N/A 9-1/2 in24.1 cm N/A 16-1/4 in41.2 cm N/A 16-1/4 in41.2 cm N/A 16-1/4 in41.2 cm
Dimension C N/A 70-1/2 in179.1 cm N/A 70-1/2 in179.1 cm N/A 78-1/4 in198.8 cm N/A 78-1/4 in198.8 cm N/A 78-1/4 in198.8 cm
Dimension D N/A 58-1/4 in147.8 cm N/A 58-1/4 in147.8 cm N/A 65-3/4 in167 cm N/A 65-3/4 in167 cm N/A 65-3/4 in167 cm
Dimension E N/A 26-1/4 in66.5 cm N/A 26-1/4 in66.5 cm N/A 25-3/4 in65.4 cm N/A 25-3/4 in65.4 cm N/A 25-3/4 in65.4 cm
Dimension F N/A 21 in53.3 cm
Dimension G N/A 1/2 in. NPT N/A 1/2 in. NPT N/A 3/4 in. NPT N/A 3/4 in. NPT N/A 3/4 in. NPT
Dimension H N/A 58-1/2 in148.8 cm N/A 58-1/2 in148.8 cm N/A 66-1/4 in168.3 cm N/A 66-1/4 in168.3 cm N/A 66-1/4 in168.3 cm
Dimension I N/A 6 in15.2 cm
Dimension J N/A 27-3/4 in70.5 cm
Dimension K N/A 1/2 in. NPT N/A 1/2 in. NPT N/A 1-1/2 in. NPT N/A 1-1/2 in. NPT N/A 1-1/2 in. NPT
Dimension L N/A 1/2 in NPT N/A 1/2 in NPT N/A 1-1/2 in NPT N/A 1-1/2 in NPT N/A 1-1/2 in NPT
Dimension M N/A 38-1/2 in97.8 cm N/A 38-1/2 in97.8 cm N/A 41 in104 cm N/A 41 in104 cm N/A 41 in104 cm
Input Power N/A 120000 KBTU/hr35 kW N/A 154000 KBTU/hr45 kW N/A 275000 KBTU/hr81 kW N/A 275000 KBTU/hr81 kW N/A 310000 KBTU/hr91 kW
Capacity N/A 81 U.S. gal307 L N/A 81 U.S. gal307 L N/A 85 U.S. gal322 L N/A 85 U.S. gal322 L N/A 85 U.S. gal322 L
Thermal Efficiency N/A 82 %
Standard Type N/A Non-ASME N/A Non-ASME N/A ASME N/A Non-ASME N/A ASME
Recovery at 36 ºF Temperature Rise N/A 331 gal/h N/A 425 gal/h N/A 754 gal/h N/A 754 gal/h N/A 849 gal/h
Recovery at 20 ºC Temperature Rise N/A 1254 L/h N/A 1609 L/h N/A 2853 L/h N/A 2853 L/h N/A 3216 L/h
Recovery at 40 ºF Temperature Rise N/A 298 gal/h N/A 383 gal/h N/A 678 gal/h N/A 678 gal/h N/A 765 gal/h
Recovery at 22 ºC Temperature Rise N/A 1129 L/h N/A 1448 L/h N/A 2567 L/h N/A 2567 L/h N/A 2894 L/h
Recovery at 50 ºF Temperature Rise N/A 239 gal/h N/A 306 gal/h N/A 543 gal/h N/A 543 gal/h N/A 612 gal/h
Recovery at 28 ºC Temperature Rise N/A 903 L/h N/A 1159 L/h N/A 2054 L/h N/A 2054 L/h N/A 2315 L/h
Recovery at 54 ºF Temperature Rise N/A 221 gal/h N/A 283 gal/h N/A 502 gal/h N/A 502 gal/h N/A 566 gal/h
Recovery at 30 ºC Temperature Rise N/A 836 L/h N/A 1073 L/h N/A 1902 L/h N/A 1902 L/h N/A 2144 L/h
Recovery at 60 ºF Temperature Rise N/A 199 gal/h N/A 255 gal/h N/A 452 gal/h N/A 452 gal/h N/A 510 gal/h
Recovery at 33 ºC Temperature Rise N/A 752 L/h N/A 966 L/h N/A 1712 L/h N/A 1712 L/h N/A 1929 L/h
Recovery at 70 ºF Temperature Rise N/A 170 gal/h N/A 219 gal/h N/A 388 gal/h N/A 388 gal/h N/A 437 gal/h
Recovery at 39 ºC Temperature Rise N/A 645 L/h N/A 828 L/h N/A 1467 L/h N/A 1467 L/h N/A 1654 L/h
Recovery at 72 ºF Temperature Rise N/A 166 gal/h N/A 213 gal/h N/A 377 gal/h N/A 377 gal/h N/A 425 gal/h
Recovery at 40 ºC Temperature Rise N/A 627 L/h N/A 805 L/h N/A 1426 L/h N/A 1426 L/h N/A 1608 L/h
Recovery at 80 ºF Temperature Rise N/A 149 gal/h N/A 191 gal/h N/A 339 gal/h N/A 339 gal/h N/A 382 gal/h
Recovery at 44 ºC Temperature Rise N/A 564 L/h N/A 724 L/h N/A 1284 L/h N/A 1284 L/h N/A 1447 L/h
Recovery at 90 ºF Temperature Rise N/A 133 gal/h N/A 170 gal/h N/A 301 gal/h N/A 301 gal/h N/A 340 gal/h
Recovery at 50 ºC Temperature Rise N/A 502 L/h N/A 644 L/h N/A 1141 L/h N/A 1141 L/h N/A 1286 L/h
Recovery at 100 ºF Temperature Rise N/A 119 gal/h N/A 153 gal/h N/A 271 gal/h N/A 271 gal/h N/A 306 gal/h
Recovery at 56 ºC Temperature Rise N/A 451 L/h N/A 579 L/h N/A 1027 L/h N/A 1027 L/h N/A 1158 L/h
Recovery at 108 ºF Temperature Rise N/A 110 gal/h N/A 142 gal/h N/A 251 gal/h N/A 251 gal/h N/A 283 gal/h
Recovery at 60 ºC Temperature Rise N/A 418 L/h N/A 536 L/h N/A 951 L/h N/A 951 L/h N/A 1072 L/h
Recovery at 110 ºF Temperature Rise N/A 108 gal/h N/A 139 gal/h N/A 247 gal/h N/A 247 gal/h N/A 278 gal/h
Recovery at 61 ºC Temperature Rise N/A 410 L/h N/A 527 L/h N/A 934 L/h N/A 934 L/h N/A 1052 L/h
Recovery at 120 ºF Temperature Rise N/A 99 gal/h N/A 128 gal/h N/A 226 gal/h N/A 226 gal/h N/A 255 gal/h
Recovery at 67 ºC Temperature Rise N/A 376 L/h N/A 483 L/h N/A 856 L/h N/A 856 L/h N/A 965 L/h
Recovery at 126 ºF Temperature Rise N/A 95 gal/h N/A 121 gal/h N/A 215 gal/h N/A 215 gal/h N/A 243 gal/h
Recovery at 70 ºC Temperature Rise N/A 358 L/h N/A 460 L/h N/A 815 L/h N/A 815 L/h N/A 919 L/h
Recovery at 130 ºF Temperature Rise N/A 92 gal/h N/A 118 gal/h N/A 209 gal/h N/A 209 gal/h N/A 235 gal/h
Recovery at 72 ºC Temperature Rise N/A 347 L/h N/A 446 L/h N/A 790 L/h N/A 790 L/h N/A 890 L/h
Recovery at 140 ºF Temperature Rise N/A 85 gal/h N/A 109 gal/h N/A 194 gal/h N/A 194 gal/h N/A 218 gal/h
Recovery at 78 ºC Temperature Rise N/A 322 L/h N/A 414 L/h N/A 734 L/h N/A 734 L/h N/A 827 L/h
Minimum Gas Supply Pressure N/A 0.87 kPa3.50 inWc
Maximum Gas Supply Pressure N/A 14 inWc3.48 kPa
Voltage N/A 120 V
Frequency N/A 60 Hz
Current N/A <5 A
Sides and Rear Clearance to Combustibles N/A 0 in
Top Cover Clearance to Combustibles N/A 12 in
Sides and Rear Clearance to Non-Combustibles N/A 0 in
Top Cover Clearance to Non-Combustibles N/A 12 in
Top Inlet Water Connection N/A 1-1/2 in
Front Inlet Water Connection N/A 1-1/2 in
Back Inlet Water Connection N/A 1-1/2 in
Top Outlet Water Connection N/A 1-1/2 in
Front Outlet Water Connection N/A 1-1/2 in
Back Outlet Water Connection N/A 1-1/2 in
Standard Approximate Shipping Weight N/A 750 lb340 kg N/A 750 lb340 kg N/A N/A 850 lb386 kg N/A
ASME Approximate Shipping Weight N/A N/A N/A 900 lb408 kg N/A N/A 900 lb408 kg
Features N/A 82% thermal efficiency means lower operating costs.

Fan Assisted Combustion
  • The blower is built into the Low NOx burner assembly for Ultra-Low NOx readings that comply with SCQAMD rule 1146.2 of 14 ng/j or 20 ppm.
Metal Venting
  • Rated Category I Appliance. Uses standard double wall type "B" vent.
  • Can be commonly vented with other Category I appliances.
  • Vent connects directly to the vent connector outlet.
  • No Draft hood or barometric damper required.
  • Perfect choice for retrofit and upgrade installations.
Water Connections
  • For ease of installation, all BCL3s feature water connections on the top, front, and rear.
  • Self Cleaning inlet water connection eliminates harmful scale buildup, extending the life of the product.
  • The front inlet connection must be used for the Self Cleaning benefits.
Glasslined Tank
  • Our proprietary slush coating is applied after the complete tank has been assembled to give a seamless barrier against hot water corrosion.
  • Maximum working pressure 160 psi.
Installed Cost Savings
  • When multiple BCL3 units are exclusively used in a vent manifold, use the National Fuel Gas Code Table 13 Vent Sizing information to determine vent diameter and specifications.
Fully Automatic Digital Control with Safety Shutoff
  • Accurate, dependable control system. Features a two speed blower control for smooth main burner light off.
  • Manual reset gas shutoff device for added safety.
  • Maximum inlet gas pressure is 14" W.C. Minimum gas pressure is 3.5" W.C. Natural Gas.
Foam Insulation
  • Saves fuel, helps reduce standby heat loss.
Jacket
  • Heavy gauge steel finished with a baked enamel finish over a bonderized undercoat.
Easy Cleaning
  • Handhole cleanout allows access for easy cleaning.
Fully Tested for Safety and Performance
  • Design certified by the Underwriters Laboratory for 180 ºF hot water service.
  • Meets rigid requirements of the National Sanitation Foundation when equipped with optional leg kit.
  • Certified for use on combustible flooring.
Intermittent Ignition Device.
  • Eliminates standing pilot.
  • Provides flame failure response in less than one second.
  • Spark ignitor and power ON/OFF switch.
Easy-To-Install
  • Completely factory-assembled.
  • Only gas, water, vent and electric connections need be made.
  • Provided with drain valve.
Anodes
  • Long-life, stainless steel core anode rods.
Plug Kits
  • Pipe nipples and caps are included to plug unused water connections.
Testing and Certifications N/A Approval Ratings and Certification
  • All models meet ANSI Z21.10.3 - CSA 4.3 standards and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
Other Features N/A
  • Integral automatic gas shutoff system prevents excessive water temperature
  • CSA Certified and ASME Rated T&P Relief Valve are factory-installed
  • Maximum working pressure is 160 psi standard
  • Adjustable thermostat with a 120 to 180 ºF range
  • All models certified up to 7,700 ft
Options N/A
  • Meets NSF Standard 5 with optional leg kit - Part #9008214005
Type N/A Natural Gas
Style N/A Ultra-Low NOx Heavy-Duty
Size N/A C
Industry Standards N/A AHRI Certified® ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed
Warranty N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.
Note N/A Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

All models rated at 82% thermal efficiency.

Models available for sale in California only.