Manufacturer N/A Bradford White®
Capacity N/A 48 U.S. gal40 Imp. gal182 L N/A 48 U.S. gal40 Imp. gal182 L N/A 48 U.S. gal40 Imp. gal182 L N/A 48 U.S. gal40 Imp. gal182 L N/A 65 U.S. gal54 Imp. gal246 L
Input Power N/A 65000 BTU/hr19.1 kW N/A 61000 BTU/hr17.9 kW N/A 65000 BTU/hr19.1 kW N/A 61000 BTU/hr17.9 kW N/A 65000 BTU/hr19.1 kW
First Hour Rating1 N/A 103 gal390 L N/A 103 gal390 L N/A 103 gal390 L N/A 103 gal390 L N/A 127 gal481 L
Recovery at 100 ºF Temperature Rise
N/A 63 U.S. gal/h53 Imp. gal/h N/A 59 U.S. gal/h49 Imp. gal/h N/A 63 U.S. gal/h53 Imp. gal/h N/A 59 U.S. gal/h49 Imp. gal/h N/A 63 U.S. gal/h53 Imp. gal/h
Recovery at 56 ºC Temperature Rise
N/A 238 L/h N/A 223 L/h N/A 238 L/h N/A 223 L/h N/A 238 L/h
Type N/A Natural Gas N/A Liquid Propane Gas N/A Natural Gas N/A Liquid Propane Gas N/A Natural Gas
Schematic N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters
Floor to Flue Connection A N/A 59-1/4 in1550 mm N/A 59-1/4 in1550 mm N/A 59-1/4 in1550 mm N/A 59-1/4 in1550 mm N/A 63 in1600 mm
Jacket Diameter B N/A 22 in559 mm N/A 22 in559 mm N/A 22 in559 mm N/A 22 in559 mm N/A 24 in609 mm
Vent Size C N/A 4 in102 mm
Floor to T and P Connection D N/A 50 in1270 mm N/A 50 in1270 mm N/A 50 in1270 mm N/A 50 in1270 mm N/A 53-1/2 in1359 mm
Floor to Gas Connection E N/A 13 in330 mm N/A 13 in330 mm N/A 13 in330 mm N/A 13 in330 mm N/A 12-3/16 in309 mm
Floor to Space Heating Return F N/A 13-1/2 in343 mm N/A 13-1/2 in343 mm N/A 13-1/2 in343 mm N/A 13-1/2 in343 mm N/A 13-1/2 in342 mm
Floor to Space Heating Outlet G N/A 50 in1270 mm N/A 50 in1270 mm N/A 50 in1270 mm N/A 50 in1270 mm N/A 53-1/2 in1359 mm
Floor to Water Connection H N/A 57 in1448 mm N/A 57 in1448 mm N/A 57 in1448 mm N/A 57 in1448 mm N/A 60-3/4 in1543 mm
Depth K N/A 26 in660 mm N/A 26 in660 mm N/A 26 in660 mm N/A 26 in660 mm N/A 28 in711 mm
Approximate Shipping Weight N/A 164 lb74 kg N/A 164 lb74 kg N/A 164 lb74 kg N/A 164 lb74 kg N/A 205 lb93 kg
Test Pressure N/A 300 psi2068 kPa
Working Pressure N/A 150 psi1034 kPa
Style N/A Light-Duty Atmospheric Vent
Size N/A C
Industry Standards N/A ANSI Standards Z-21.10.1 ASHRAE 90.1b (Current Standards) C.E.C. Listed CSA® Certified
Features N/A The Atmospheric Vent FVIR Defender Safety System® Models Feature:
  • Bradford White ICON System™ - Intelligent gas control with proven millivolt powered technology and built-in piezo igniter. A standard, off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity.
    • Enhanced Performance - Proprietary algorithms provide enhanced First Hour Delivery ratings and tighter temperature differentials.
    • Advanced Temperature Control System - Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels (up to 180 ºF).
    • Intelligent Diagnostics - An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting.
    • Pilot On Indication - Flashing green LED provides positive indication that pilot is on.
    • Separate Immersed Thermowell - High strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve.
  • Advanced ScreenLok® Technology Flame Arrestor Design-Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater.
  • Resettable Thermal Switch - Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow.
  • Maintenance Free - No regular cleaning of air inlet openings or flame arrestor is required under normal conditions.
  • Sight Window - Offers a view into the combustion chamber to observe the operation of the pilot and burner.
  • Factory Installed Hydrojet® Total Performance System - Cold water inlet sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.
  • Vitraglas® Lining - Bradford White tanks are lined with a exclusively engineered enamel formula that provides superior protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600 ºF.
  • Side Connections - 3/4" NPT tappings allow easy connections for space heating applications (potable water only).
  • 2" Non-CFC Foam Insulation - Covers the sides and top of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
  • Pedestal Base.
  • Water Connections - 3/4" NPT factory installed true dielectric fittings.
  • Factory Installed Heat Traps.
  • Protective Magnesium Anode Rod.
  • 4" "Snap Lock" Draft Diverter.
  • T & P Relief Valve - Installed.
  • Low Restriction Brass Drain Valve - Durable tamper proof design.
General Information N/A All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All potable water connections are 3/4" NPT (19 mm) on 8" (203 mm) centers. All gas connections 1/2" (13 mm).

All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
Warranty N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.
N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.
N/A
  • 5-Year Limited Tank Warranty.
  • 1-Year Limited Warranty on Component Parts.
N/A
  • 5-Year Limited Tank Warranty.
  • 1-Year Limited Warranty on Component Parts.
N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.
Note N/A Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency.

NSF kits available.

Meets NAECA Requirements.
N/A Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency.

Propane models feature a Titanium Stainless Steel propane burner.

NSF kits available.

Meets NAECA Requirements.
N/A Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency.

NSF kits available.

Meets NAECA Requirements.
N/A Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency.

Propane models feature a Titanium Stainless Steel propane burner.

NSF kits available.

Meets NAECA Requirements.
N/A Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency.

NSF kits available.

Meets NAECA Requirements.
  • 1 First Hour Rating is based on the latest AHRI Directory listings.