Catalog
AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters
Rheem® High Efficiency NON NOx Commercial Water Heaters
AdvantagePlus™ is a family of ultra high efficiency commercial gas water heaters with 95 percent thermal efficiency for lower operating costs.
Unit of Measure
Items |
/Asset/a1356.jpg HE55-100 AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters |
/Asset/a1356.jpg HE55-130 AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters |
/Asset/a1356.jpg HE80-160 AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters |
/Asset/a1356.jpg HE119-199 AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters |
/Asset/a1356.jpg HE80-130 AdvantagePlus™ Ultra-High Efficiency Commercial Gas Water Heaters |
|||||
Description | N/A AdvantagePlus™ is a family of ultra high efficiency commercial gas water heaters with 95 percent thermal efficiency for lower operating costs. | |||||||||
Manufacturer | N/A Rheem® | |||||||||
Tank Capacity | N/A 55 gal208 L | N/A 55 gal208 L | N/A 55 gal208 L | N/A 55 gal208 L | N/A 80 gal303 L | |||||
Input Power | N/A 100000 BTU/hr | N/A 130000 BTU/hr | N/A 160000 BTU/hr | N/A 199000 BTU/hr | N/A 130000 BTU/hr | |||||
Thermal Efficiency | N/A 95 % | |||||||||
Recovery at 40 ºF Temperature Rise | N/A 288 U.S. gal/h | N/A 374 U.S. gal/h | N/A 461 U.S. gal/h | N/A 573 U.S. gal/h | N/A 374 U.S. gal/h | |||||
Recovery at 22 ºC Temperature Rise | N/A 1090 L/h | N/A 1417 L/h | N/A 1744 L/h | N/A 2169 L/h | N/A 1417 L/h | |||||
Recovery at 50 ºF Temperature Rise | N/A 230 U.S. gal/h | N/A 299 U.S. gal/h | N/A 368 U.S. gal/h | N/A 458 U.S. gal/h | N/A 299 U.S. gal/h | |||||
Recovery at 28 ºC Temperature Rise | N/A 872 L/h | N/A 1133 L/h | N/A 1395 L/h | N/A 1735 L/h | N/A 1133 L/h | |||||
Recovery at 60 ºF Temperature Rise | N/A 192 U.S. gal/h | N/A 249 U.S. gal/h | N/A 307 U.S. gal/h | N/A 382 U.S. gal/h | N/A 249 U.S. gal/h | |||||
Recovery at 33 ºC Temperature Rise | N/A 726 L/h | N/A 944 L/h | N/A 1162 L/h | N/A 1446 L/h | N/A 944 L/h | |||||
Recovery at 70 ºF Temperature Rise | N/A 165 U.S. gal/h | N/A 214 U.S. gal/h | N/A 263 U.S. gal/h | N/A 327 U.S. gal/h | N/A 214 U.S. gal/h | |||||
Recovery at 39 ºC Temperature Rise | N/A 623 L/h | N/A 809 L/h | N/A 996 L/h | N/A 1239 L/h | N/A 809 L/h | |||||
Recovery at 80 ºF Temperature Rise | N/A 144 U.S. gal/h | N/A 187 U.S. gal/h | N/A 230 U.S. gal/h | N/A 286 U.S. gal/h | N/A 187 U.S. gal/h | |||||
Recovery at 45 ºC Temperature Rise | N/A 545 L/h | N/A 708 L/h | N/A 872 L/h | N/A 1084 L/h | N/A 708 L/h | |||||
Recovery at 90 ºF Temperature Rise | N/A 128 U.S. gal/h | N/A 166 U.S. gal/h | N/A 205 U.S. gal/h | N/A 255 U.S. gal/h | N/A 166 U.S. gal/h | |||||
Recovery at 50 ºC Temperature Rise | N/A 484 L/h | N/A 630 L/h | N/A 775 L/h | N/A 964 L/h | N/A 630 L/h | |||||
Recovery at 100 ºF Temperature Rise | N/A 115 U.S. gal/h | N/A 150 U.S. gal/h | N/A 184 U.S. gal/h | N/A 229 U.S. gal/h | N/A 150 U.S. gal/h | |||||
Recovery at 56 ºC Temperature Rise | N/A 436 L/h | N/A 567 L/h | N/A 697 L/h | N/A 867 L/h | N/A 567 L/h | |||||
Recovery at 110 ºF Temperature Rise | N/A 105 U.S. gal/h | N/A 136 U.S. gal/h | N/A 167 U.S. gal/h | N/A 208 U.S. gal/h | N/A 136 U.S. gal/h | |||||
Recovery at 61 ºC Temperature Rise | N/A 396 L/h | N/A 515 L/h | N/A 634 L/h | N/A 789 L/h | N/A 515 L/h | |||||
Recovery at 67 ºC Temperature Rise | N/A 363 L/h | N/A 472 L/h | N/A 581 L/h | N/A 723 L/h | N/A 472 L/h | |||||
Recovery at 120 ºF Temperature Rise | N/A 96 U.S. gal/h | N/A 125 U.S. gal/h | N/A 154 U.S. gal/h | N/A 191 U.S. gal/h | N/A 125 U.S. gal/h | |||||
Recovery at 130 ºF Temperature Rise | N/A | |||||||||
Recovery at 72 ºC Temperature Rise | N/A | |||||||||
Recovery at 140 ºF Temperature Rise | N/A | |||||||||
Recovery at 78 ºC Temperature Rise | N/A | |||||||||
Maximum Delivery at 100 ºF (5 Minutes) | N/A 48 U.S. gal | N/A 51 U.S. gal | N/A 54 U.S. gal | N/A 58 U.S. gal | N/A 68 U.S. gal | |||||
Maximum Delivery at 56 ºC (5 Minutes) | N/A 182 L | N/A 193 L | N/A 204 L | N/A 218 L | N/A 259 L | |||||
Maximum Delivery at 100 ºF (10 Minutes) | N/A 58 U.S. gal | N/A 63 U.S. gal | N/A 69 U.S. gal | N/A 77 U.S. gal | N/A 81 U.S. gal | |||||
Maximum Delivery at 56 ºC (10 Minutes) | N/A 219 L | N/A 240 L | N/A 262 L | N/A 291 L | N/A 306 L | |||||
Maximum Delivery at 100 ºF (15 Minutes) | N/A 67 U.S. gal | N/A 76 U.S. gal | N/A 85 U.S. gal | N/A 96 U.S. gal | N/A 93 U.S. gal | |||||
Maximum Delivery at 56 ºC (15 Minutes) | N/A 255 L | N/A 288 L | N/A 320 L | N/A 363 L | N/A 354 L | |||||
Maximum Delivery at 100 ºF (20 Minutes) | N/A 77 U.S. gal | N/A 88 U.S. gal | N/A 100 U.S. gal | N/A 115 U.S. gal | N/A 106 U.S. gal | |||||
Maximum Delivery at 56 ºC (20 Minutes) | N/A 291 L | N/A 335 L | N/A 379 L | N/A 435 L | N/A 401 L | |||||
Maximum Delivery at 100 ºF (30 Minutes) | N/A 96 U.S. gal | N/A 113 U.S. gal | N/A 131 U.S. gal | N/A 153 U.S. gal | N/A 131 U.S. gal | |||||
Maximum Delivery at 56 ºC (30 Minutes) | N/A 364 L | N/A 430 L | N/A 495 L | N/A 580 L | N/A 495 L | |||||
Maximum Delivery at 100 ºF (45 Minutes) | N/A 125 U.S. gal | N/A 151 U.S. gal | N/A 177 U.S. gal | N/A 210 U.S. gal | N/A 168 U.S. gal | |||||
Maximum Delivery at 56 ºC (45 Minutes) | N/A 473 L | N/A 571 L | N/A 670 L | N/A 797 L | N/A 637 L | |||||
Maximum Delivery at 100 ºF (60 Minutes) | N/A 154 U.S. gal | N/A 188 U.S. gal | N/A 223 U.S. gal | N/A 268 U.S. gal | N/A 206 U.S. gal | |||||
Maximum Delivery at 56 ºC (60 Minutes) | N/A 582 L | N/A 713 L | N/A 844 L | N/A 1014 L | N/A 779 L | |||||
Maximum Delivery at 100 ºF (120 Minutes) | N/A 269 U.S. gal | N/A 338 U.S. gal | N/A 407 U.S. gal | N/A 497 U.S. gal | N/A 355 U.S. gal | |||||
Maximum Delivery at 56 ºC (120 Minutes) | N/A 1019 L | N/A 1281 L | N/A 1542 L | N/A 1883 L | N/A 1345 L | |||||
Maximum Delivery at 100 ºF (180 Minutes) | N/A 384 U.S. gal | N/A 488 U.S. gal | N/A 591 U.S. gal | N/A 726 U.S. gal | N/A 505 U.S. gal | |||||
Maximum Delivery at 56 ºC (180 Minutes) | N/A 1455 L | N/A 1848 L | N/A 2241 L | N/A 2751 L | N/A 1912 L | |||||
Minimum to Recovery Contents | N/A 29 | N/A 22 | N/A 18 | N/A 14 | N/A 32 | |||||
Schematic |
N/A
Schematic Drawing for AdvantagePlus™ Ultra High Efficiency Commercial Gas Water Heaters |
|||||||||
Dimension A | N/A 52 in1321 mm | N/A 52 in1321 mm | N/A 72 in1854 mm | N/A 73 in1854 mm | N/A 52 in1321 mm | |||||
Dimension B | N/A 23-1/2 in597 mm | N/A 23-1/2 in597 mm | N/A 23-1/2 in597 mm | N/A 27 in686 mm | N/A 23-1/2 in597 mm | |||||
Dimension C | N/A 32 in813 mm | N/A 32 in813 mm | N/A 32 in813 mm | N/A 36 in914 mm | N/A 32 in813 mm | |||||
Dimension D | N/A 45 in1143 mm | N/A 45 in1143 mm | N/A 65 in1651 mm | N/A 66-3/4 in1695 mm | N/A 45 in1143 mm | |||||
Dimension E | N/A 5 in127 mm | N/A 5 in127 mm | N/A 5 in127 mm | N/A 6-3/4 in171 mm | N/A 5 in127 mm | |||||
Dimension F | N/A 25-1/4 in641 mm | N/A 25-1/4 in641 mm | N/A 25-1/4 in641 mm | N/A 28-7/8 in733 mm | N/A 25-1/4 in641 mm | |||||
Dimension G | N/A 27-9/16 in700 mm | N/A 27-9/16 in700 mm | N/A 20-1/4 in514 mm | N/A 22 in559 mm | N/A 27-9/16 in700 mm | |||||
Dimension H | N/A 5-7/8 in149 mm | N/A 5-7/8 in149 mm | N/A 7-3/4 in197 mm | N/A 9-1/2 in241 mm | N/A 5-7/8 in149 mm | |||||
Vent Size | N/A 2 in51 mm | N/A 2 in51 mm | N/A 3 in76 mm | N/A 3 in76 mm | N/A 3 in76 mm | |||||
Inlet Water Connection | N/A 1 in25 mm | N/A 1 in25 mm | N/A 1-1/2 in38 mm | N/A 1-1/2 in38 mm | N/A 1 in25 mm | |||||
Outlet Water Connection | N/A 1 in25 mm | N/A 1 in25 mm | N/A 1-1/2 in38 mm | N/A 1-1/2 in38 mm | N/A 1 in25 mm | |||||
Approximate Shipping Weight | N/A 175 lb79 kg | N/A 175 lb79 kg | N/A 235 lb106 kg | N/A 405 lb184 kg | N/A 175 lb79 kg | |||||
Type | N/A Liquid Propane Gas Natural Gas | |||||||||
Style | N/A AdvantagePlus™ | |||||||||
Size | N/A C | |||||||||
Material | N/A 316 Stainless Steel | |||||||||
Industry Standards | N/A AHRI Certified® NSF UL® Listed | |||||||||
Features and Benefits |
N/A
Rheem AdvantagePlus™ water heaters offer ultra high efficiency and reliability. Models are available that range from 100,000-199,000 Btu/h, with a temperature setting from 70 to 160 degrees Fahrenheit; 180 degree maximum temperature available on HE55-160 and HE55-199 models, with included booster kit. Efficiency
Self-diagnostic electronic control with HSI ignition control and diagnostics. Technology & Construction The heart of the system is a coil heat exchanger, which is constructed of corrosion resistant, high efficiency, 90/10 cupronickel. Stainless steel tank construction requires no anode rods. Durable plastic exterior shell. Removable Front Cover Allows for easy access to equipment (24 inches of service clearance is recommended). Low Cost Venting No chimney required. Vents through standard PVC, CPVC and ABS pipes, with a vent run up to 85 feet total for exhaust and intake. Power Direct Vent. Install as a two pipe power direct vent when air quality or negative air pressure are issues. Optional concentric vent kits are available for side or vertical venting. Optional aluminum outside vent termination kit. Ultra Low NOx Burner Design reduces NOx emissions to less than 14 ng/J. (SCAQMD Rule 1146.2 compliant). Clearances Zero clearance to combustibles. |
|||||||||
General Information |
N/A
Certification & Ratings AdvantagePlus commercial water heaters are UL/ULCX listed and exceed the minimum efficiency requirements of ASHRAE/IES 901b-1992. They are supplied with an CSA/ASME rated temperature and pressure relief valve. The control panel is an integrated solid state temperature and ignition control device with integral diagnostics, LED fault display capability and digital display of temperature setting. All models are North Carolina Code compliant. Meet all safety and construction requirements of ANSI Z-21.10.3. Certified for 150 psi maximum working pressure. |
|||||||||
Testing and Certifications |
N/A
CSA®/ASME Rated T&P Valve Factory installed relief valve Altitude Certification Certified up to 10,000 feet above sea level |
|||||||||
Warranty |
N/A
|
|||||||||
Booster Installation Kit includes |
N/A
|
|||||||||
Note |
N/A
No Chimney Required Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory. Maximum setpoint of 160 ºF. All models require a 120 V power source. 0" clearance to combustibles on all advantage plus units, however, a 24" control panel service clearance is recommended. Models with inputs of 100,000 BTU/hr and 130,000 BTU/hr are certified to vent with 2" schedule 40 PVC or CPVC pipe. (For Canadian Installation please use ULC-S636 PVC or CPVC pipe.) An aluminum outside vent termination kit is also available. (SP12162) |
N/A
No Chimney Required Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory. Maximum setpoint of 160 ºF. All models require a 120 V power source. 0" clearance to combustibles on all advantage plus units, however, a 24" control panel service clearance is recommended. Models with inputs of 100,000 BTU/hr and 130,000 BTU/hr are certified to vent with 2" schedule 40 PVC or CPVC pipe. (For Canadian Installation please use ULC-S636 PVC or CPVC pipe.) An aluminum outside vent termination kit is also available. (SP12162) |
N/A
No Chimney Required Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory. Maximum setpoint of 160 ºF. 130,000 Btu/h models are certified to be installed with 2" venting. All models require a 120 V power source. 0" clearance to combustibles on all advantage plus units, however, a 24" control panel service clearance is recommended. Models with inputs of 100,000 BTU/hr and 130,000 BTU/hr are certified to vent with 2" schedule 40 PVC or CPVC pipe. (For Canadian Installation please use ULC-S636 PVC or CPVC pipe.) An aluminum outside vent termination kit is also available. (SP12162) |
N/A
No Chimney Required Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory. Maximum setpoint of 160 ºF. 130,000 Btu/h models are certified to be installed with 2" venting. All models require a 120 V power source. 0" clearance to combustibles on all advantage plus units, however, a 24" control panel service clearance is recommended. Models with inputs of 100,000 BTU/hr and 130,000 BTU/hr are certified to vent with 2" schedule 40 PVC or CPVC pipe. (For Canadian Installation please use ULC-S636 PVC or CPVC pipe.) An aluminum outside vent termination kit is also available. (SP12162) |
N/A
No Chimney Required Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory. Maximum setpoint of 160 ºF. All models require a 120 V power source. 0" clearance to combustibles on all advantage plus units, however, a 24" control panel service clearance is recommended. Models with inputs of 100,000 BTU/hr and 130,000 BTU/hr are certified to vent with 2" schedule 40 PVC or CPVC pipe. (For Canadian Installation please use ULC-S636 PVC or CPVC pipe.) An aluminum outside vent termination kit is also available. (SP12162) |
|||||
|