Catalog
Unit of Measure
Specifications
|
Dimensions
|
Maximum Recovery
|
Electrical Characteristics
|
Clearances to Combustibles
|
Water Connection
|
Features
|
Testing and Certifications
|
Other Features
|
Warranty
|
Note
Specifications
Manufacturer |
N/A American® Water Heater Company |
Input Power |
N/A 250000 KBTU/hr73 kW |
Capacity |
N/A 93 U.S. gal352 L |
Thermal Efficiency |
N/A 82 % |
Standard Type |
N/A Non-ASME |
Minimum Gas Supply Pressure |
N/A 0.87 kPa3.50 inWc |
Maximum Gas Supply Pressure |
N/A 14 inWc3.48 kPa |
Standard Approximate Shipping Weight |
N/A 835 lb379 kg |
Options |
N/A
|
Type |
N/A Natural Gas |
Style |
N/A Ultra-Low NOx Heavy-Duty |
Size |
N/A C |
Industry Standards |
N/A AHRI Certified® ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed |
Dimensions
Maximum Recovery
Recovery at 36 ºF Temperature Rise |
N/A 690 gal/h |
Recovery at 20 ºC Temperature Rise |
N/A 2613 L/h |
Recovery at 40 ºF Temperature Rise |
N/A 621 gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 2351 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 497 gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 1881 L/h |
Recovery at 54 ºF Temperature Rise |
N/A 460 gal/h |
Recovery at 30 ºC Temperature Rise |
N/A 1742 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 414 gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 1568 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 355 gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 1344 L/h |
Recovery at 72 ºF Temperature Rise |
N/A 345 gal/h |
Recovery at 40 ºC Temperature Rise |
N/A 1306 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 311 gal/h |
Recovery at 44 ºC Temperature Rise |
N/A 1176 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 276 gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 1045 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 248 gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 941 L/h |
Recovery at 108 ºF Temperature Rise |
N/A 230 gal/h |
Recovery at 60 ºC Temperature Rise |
N/A 871 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 226 gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 855 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 207 gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 784 L/h |
Recovery at 126 ºF Temperature Rise |
N/A 197 gal/h |
Recovery at 70 ºC Temperature Rise |
N/A 746 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 191 gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 723 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 177 gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 672 L/h |
Clearances to Combustibles
Sides and Rear Clearance to Combustibles |
N/A 0 in |
Top Cover Clearance to Combustibles |
N/A 12 in |
Sides and Rear Clearance to Non-Combustibles |
N/A 0 in |
Top Cover Clearance to Non-Combustibles |
N/A 12 in |
Water Connection
Top Inlet Water Connection |
N/A 1-1/2 in |
Front Inlet Water Connection |
N/A 1-1/2 in |
Back Inlet Water Connection |
N/A 1-1/2 in |
Top Outlet Water Connection |
N/A 1-1/2 in |
Front Outlet Water Connection |
N/A 1-1/2 in |
Back Outlet Water Connection |
N/A 1-1/2 in |
Features
Features |
N/A
82% thermal efficiency means lower operating costs. Fan Assisted Combustion
|
Testing and Certifications
Testing and Certifications |
N/A
Approval Ratings and Certification
|
Other Features
Other Features |
N/A
|