Catalog
The HCG Series High Efficiency Commercial Gas Water Heaters embody all that's great about the American brand. They're designed for outstanding reliability, maximum installation flexibility and, above all, excellent thermal efficiency. In comparison to standard water heaters with only 80% efficiency, they deliver up to 400,000 BTU input and up to 96% efficiency. With their small footprint and top mounted controls, HCG Series units are a natural cost-saving choice for restaurants and other similar applications. ENERGY STAR® Qualified.
Unit of Measure
Specifications
|
Maximum Recovery
|
Dimensions
|
Electrical Characteristics
|
3" Vent Pipe
|
4" Vent Pipe
|
Features
|
Other Features
|
Warranty
|
General Information
|
Note
Specifications
Manufacturer |
N/A American® Water Heater Company |
Standard Type |
N/A Non-ASME |
Input Power |
N/A 120000 BTU/hr35 kW |
Thermal Efficiency |
N/A 95 % |
Approximate Capacity |
N/A 60 U.S. gal227 L |
Maximum Hydrostatic Working Pressure |
N/A 160 psi |
Standard Approximate Shipping Weight |
N/A 460 lb |
ASME Approximate Shipping Weight |
N/A 490 lb |
Minimum Supply Natural Gas Line Size (N.P.T.) |
N/A 1/2 in |
Minimum Supply Propane Gas Line Size (N.P.T.) |
N/A 1/2 in |
Type |
N/A Natural Gas |
Style |
N/A HCG Series |
Size |
N/A C |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 ASME Optional CSA® Certified Energy Star UL® Listed |
Maximum Recovery
Recovery at 30 ºF Temperature Rise |
N/A 461 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 1744 L/h |
Recovery at 40 ºF Temperature Rise |
N/A 345 gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 1308 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 276 gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 1046 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 230 gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 872 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 197 gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 747 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 173 gal/h |
Recovery at 44 ºC Temperature Rise |
N/A 654 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 154 gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 581 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 523 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 126 gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 476 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 115 gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 436 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 106 gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 402 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 99 gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 374 L/h |
Electrical Characteristics
AC Voltage |
N/A 120 V |
Frequency |
N/A 60 Hz |
Blower Current |
N/A 2.2 A |
Igniter Current |
N/A 4 A |
3" Vent Pipe
One 90º Elbows for Maximum 3" Vent Pipe |
N/A 45 ft13.7 m |
Two 90º Elbows for Maximum 3" Vent Pipe |
N/A 40 ft12.2 m |
Three 90º Elbows for Maximum 3" Vent Pipe |
N/A 35 ft10.7 m |
Four 90º Elbows for Maximum 3" Vent Pipe |
N/A 30 ft9.1 m |
4" Vent Pipe
One 90º Elbows for Maximum 4" Vent Pipe |
N/A 115 ft35 m |
Two 90º Elbows for Maximum 4" Vent Pipe |
N/A 110 ft33.5 m |
Three 90º Elbows for Maximum 4" Vent Pipe |
N/A 105 ft32 m |
Four 90º Elbows for Maximum 4" Vent Pipe |
N/A 100 ft30.5 m |
Five 90º Elbows for Maximum 4" Vent Pipe |
N/A 95 ft29 m |
Six 90º Elbows for Maximum 4" Vent Pipe |
N/A 90 ft27.4 m |
Features
Features |
N/A
Fully Submerged, Spiral-Shaped Condensing Heat Exchanger
ASME Construction
|
Other Features
Other Features |
N/A
Commercial Grade Glasslined Tank & Heat Exchanger
|
General Information
General Information |
N/A
Installation Considerations
|
Note
Note |
N/A
Recovery capacities are based on heater performance at 95% and 96% thermal efficiency. For complete information on limited warranties, consult written warranty. Maximum gas supply pressure for 10.5" W.C. natural gas 14" propane gas. Manifold pressure: 4" W.C. natural gas 10" W.C. propane. Maximum number of 90º elbows allowed for the vent (exhaust) pipe is four (4) when installing 3 inch pipe and six (6) when installing 4 inch pipe. Maximum number of 90º elbows allowed for intake air pipe is four (4) when installing 3 inch pipe and six (6) when installing 4 inch pipe. Two (2) 45º elbows equal one (1) 90º elbow. Electrical requirements: 120 VAC/60 HZ, Blower 2.2 Amps FL, Igniter 4.0 Amps. Center line of water outlet on top of water heaters is approximately 7 inches from the front edge of the water heater |