Input Power

120000 BTU/hr35 kW

Capacity

81 U.S. gal307 L

Thermal Efficiency

82 %

Minimum Gas Supply Pressure

0.87 kPa

Maximum Gas Supply Pressure

3.48 kPa

Standard Approximate Shipping Weight

750 lb340 kg

Maximum Working Pressure

160 psi

Style

Sandblaster® Ultra Low NOx

Size

C

Type

Natural Gas

Industry Standards

AHRI Certified® ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 ASME Certified CSA® 4.3 UL® Listed

Maximum Recovery

Recovery at 36 ºF Temperature Rise

331 U.S. gal/h

Recovery at 20 ºC Temperature Rise

1254 L/h

Recovery at 40 ºF Temperature Rise

298 U.S. gal/h

Recovery at 22 ºC Temperature Rise

1129 L/h

Recovery at 50 ºF Temperature Rise

239 U.S. gal/h

Recovery at 28 ºC Temperature Rise

903 L/h

Recovery at 54 ºF Temperature Rise

221 U.S. gal/h

Recovery at 30 ºC Temperature Rise

836 L/h

Recovery at 60 ºF Temperature Rise

199 U.S. gal/h

Recovery at 33 ºC Temperature Rise

752 L/h

Recovery at 70 ºF Temperature Rise

170 U.S. gal/h

Recovery at 39 ºC Temperature Rise

645 L/h

Recovery at 72 ºF Temperature Rise

166 U.S. gal/h

Recovery at 40 ºC Temperature Rise

627 L/h

Recovery at 80 ºF Temperature Rise

149 U.S. gal/h

Recovery at 44 ºC Temperature Rise

564 L/h

Recovery at 90 ºF Temperature Rise

133 U.S. gal/h

Recovery at 50 ºC Temperature Rise

502 L/h

Recovery at 100 ºF Temperature Rise

119 U.S. gal/h

Recovery at 56 ºC Temperature Rise

451 L/h

Recovery at 108 ºF Temperature Rise

110 U.S. gal/h

Recovery at 60 ºC Temperature Rise

418 L/h

Recovery at 110 ºF Temperature Rise

108 U.S. gal/h

Recovery at 61 ºC Temperature Rise

410 L/h

Recovery at 120 ºF Temperature Rise

99 U.S. gal/h

Recovery at 67 ºC Temperature Rise

376 L/h

Recovery at 126 ºF Temperature Rise

95 U.S. gal/h

Recovery at 70 ºC Temperature Rise

358 L/h

Recovery at 130 ºF Temperature Rise

92 U.S. gal/h

Recovery at 72 ºC Temperature Rise

347 L/h

Recovery at 140 ºF Temperature Rise

85 U.S. gal/h

Recovery at 78 ºC Temperature Rise

322 L/h

Dimensions

Schematic


Schematic Drawing for Sandblaster® Ultra-Low NOx Commercial Gas Tank-type Water Heaters (SBL81 120NE)

Dimension A

68-1/4 in173.4 mm

Dimension B

9-1/2 in24.1 mm

Dimension C

70-1/2 in179.1 mm

Dimension D

58-1/4 in147.8 mm

Dimension E

26-1/4 in66.5 mm

Dimension F

21 in53.3 mm

Dimension G

1/2 in. NPT

Dimension H

58-1/2 in148.8 mm

Dimension I

6 in15.2 mm

Dimension J

27-3/4 in70.5 mm

Dimension K

1-1/2 in. NPT

Dimension L

1-1/2 in. NPT

Dimension M

38-1/2 in97.8 mm

Electrical Characteristics

Minimum Water Connection

3.5 in

Maximum Water Connection

14 in

Voltage

120 V

Frequency

60 Hz

Current

<5 A

Top Cover Clearance to Combustibles

12 in

Top Cover Clearance to Non-Combustibles

12 in

Water Connection

Top Inlet Water Connection

1-1/2 in

Front Inlet Water Connection

1-1/2 in

Back Inlet Water Connection

1-1/2 in

Top Outlet Water Connection

1-1/2 in

Front Outlet Water Connection

1-1/2 in

Back Outlet Water Connection

1-1/2 in

Features

Features

82% Thermal Efficiency Means Lower Operating Costs.

Fan Assisted Combustion
  • The blower is built into the Low NOx burner assembly for Ultra-Low NOx readings that comply with SCQAMD rule1146.2 of 14 ng/j or 20 ppm.
Metal Venting
  • Rated Category I Appliance. Uses standard double wall type "B" vent.
  • Can be commonly vented with other Category I appliances.
  • Vent connects directly to the vent connector outlet.
  • No Draft hood or barometric damper required.
  • Perfect choice for retrofit and upgrade installations.
Water Connections
  • For ease of installation, all SBLs feature water connections on the top, front, and rear.
  • "Hydro Cannon" inlet water connection eliminates harmful scale buildup, extending the life of the product.
  • The front inlet connection must be used for the Hydro Cannon benefits.
Glasslined Tank
  • Glass is applie d after the complete tank has been assembled to give a seamless barrier against corrosion by hot water.
Installed Cost Savings
  • When multiple SBL units are exclusively used in a vent manifold, use the National Fuel Gas Code Table 13 Vent Sizing information to determine vent diameter than a natural draft water heater and specifications.
  • The SBL often uses a smaller vent diameter than a natural draft water heater which saves on installation cost.
Fully Automatic Digital Control with Safety Shutoff
  • Accurate, dependable control system.
  • Features a two speed blower control for smooth main burner light-off.
  • Manual reset gas shutoff device for added safety.
  • Maximum inlet gas pressure is 14" W.C. Minimum gas pressure is 3.5" W.C. Natural Gas.
Foam Insulation
  • Saves fuel, helps reduce standby heat loss.
Jacket
  • Heavy gauge steel finished with a baked enamel finish over a bonderized undercoat.
Easy Cleaning
  • Handhole cleanout allows access for easy cleaning.
Fully Tested for Safety and Performance.
  • Design certified by the Underwriters Laboratory for 180 ºF hot water service.
  • Meets rigid requirements of the National Sanitation Foundation when equipped with optional leg kit.
  • Certified for use on combustible flooring.
Intermittent Ignition Device
  • Eliminates standing pilot.
  • Provides flame failure response in less than one second.
  • Spark ignitor and power ON/OFF switch.
Easy-to-Install
  • Completely factory-assembled.
  • Only gas, water, vent and electric connections need be made.
  • Provided with drain valve.
Anodes
  • Long-life, stainless steel core anode rods.
Plug Kits
  • Pipe nipples and caps are included to plug unused water connections.
NSF Leg Kit.
  • Meets NSF Standard 5 with optional leg kit - Part #9008214005.

Testing and Certifications

Testing and Certifications

Approval Ratings and Certification
  • All models meet ANSI Z21.10.3 - CSA 4.3 standards and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1

Other Features

Other Features

  • Integral automatic gas shutoff system prevents excessive water temperature
  • CSA Certified and ASME Rated T&P Relief Valve are factory-installed
  • Maximum working pressure is 160 psi standard
  • Adjustable thermostat with a 120 to 180 ºF range
  • All models certified up to 7,700 ft

Warranty

Warranty

  • 3-Year Limited Tank Warranty / 1-Year Limited Parts Warranty.

Note

Note

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Models available for sale in California only