Items |
50T-65FB-3N Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
50T-65FS-3X Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
50T-65FB-5N Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
50T-65FS-5X Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
65T-65FB-3N Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Capacity | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 65 U.S. gal54 Imp. gal246 L | |||||
Input Power | N/A 65000 BTU/hr19.1 kW | N/A 61000 BTU/hr17.9 kW | N/A 65000 BTU/hr19.1 kW | N/A 61000 BTU/hr17.9 kW | N/A 65000 BTU/hr19.1 kW | |||||
First Hour Rating1 | N/A 103 gal390 L | N/A 103 gal390 L | N/A 103 gal390 L | N/A 103 gal390 L | N/A 127 gal481 L | |||||
Recovery at 100 ºF Temperature Rise | N/A 63 U.S. gal/h53 Imp. gal/h | N/A 59 U.S. gal/h49 Imp. gal/h | N/A 63 U.S. gal/h53 Imp. gal/h | N/A 59 U.S. gal/h49 Imp. gal/h | N/A 63 U.S. gal/h53 Imp. gal/h | |||||
Recovery at 56 ºC Temperature Rise | N/A 238 L/h | N/A 223 L/h | N/A 238 L/h | N/A 223 L/h | N/A 238 L/h | |||||
Type | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | |||||
Schematic |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent Energy Saver Gas Water Heaters |
|||||||||
Floor to Flue Connection A | N/A 59-1/4 in1550 mm | N/A 59-1/4 in1550 mm | N/A 59-1/4 in1550 mm | N/A 59-1/4 in1550 mm | N/A 63 in1600 mm | |||||
Jacket Diameter B | N/A 22 in559 mm | N/A 22 in559 mm | N/A 22 in559 mm | N/A 22 in559 mm | N/A 24 in609 mm | |||||
Vent Size C | N/A 4 in102 mm | |||||||||
Floor to T and P Connection D | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 53-1/2 in1359 mm | |||||
Floor to Gas Connection E | N/A 13 in330 mm | N/A 13 in330 mm | N/A 13 in330 mm | N/A 13 in330 mm | N/A 12-3/16 in309 mm | |||||
Floor to Space Heating Return F | N/A 13-1/2 in343 mm | N/A 13-1/2 in343 mm | N/A 13-1/2 in343 mm | N/A 13-1/2 in343 mm | N/A 13-1/2 in342 mm | |||||
Floor to Space Heating Outlet G | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 50 in1270 mm | N/A 53-1/2 in1359 mm | |||||
Floor to Water Connection H | N/A 57 in1448 mm | N/A 57 in1448 mm | N/A 57 in1448 mm | N/A 57 in1448 mm | N/A 60-3/4 in1543 mm | |||||
Depth K | N/A 26 in660 mm | N/A 26 in660 mm | N/A 26 in660 mm | N/A 26 in660 mm | N/A 28 in711 mm | |||||
Approximate Shipping Weight | N/A 164 lb74 kg | N/A 164 lb74 kg | N/A 164 lb74 kg | N/A 164 lb74 kg | N/A 205 lb93 kg | |||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Style | N/A Light-Duty Atmospheric Vent | |||||||||
Size | N/A C | |||||||||
Industry Standards | N/A ANSI Standards Z-21.10.1 ASHRAE 90.1b (Current Standards) C.E.C. Listed CSA® Certified | |||||||||
Features |
N/A
The Atmospheric Vent FVIR Defender Safety System® Models Feature:
|
|||||||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All potable water connections are 3/4" NPT (19 mm) on 8" (203 mm) centers. All gas connections 1/2" (13 mm). All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. |
|||||||||
Warranty |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Note |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency. NSF kits available. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency. Propane models feature a Titanium Stainless Steel propane burner. NSF kits available. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency. NSF kits available. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency. Propane models feature a Titanium Stainless Steel propane burner. NSF kits available. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 79% Recovery Efficiency. NSF kits available. Meets NAECA Requirements. |
|||||
|