Items |
PDX-50S-60FB-3N Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
PDX-50S-60FB-5N Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
PDX-50S-60FS-3X Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
PDX-50S-60FS-5X Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
PDX-65S-65FB-3N Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Capacity | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 48 U.S. gal40 Imp. gal182 L | N/A 65 U.S. gal54 Imp. gal246 L | |||||
Input Power | N/A 60000 BTU/hr17.6 kW | N/A 60000 BTU/hr17.6 kW | N/A 60000 BTU/hr17.6 kW | N/A 60000 BTU/hr17.6 kW | N/A 65000 BTU/hr19.0 kW | |||||
First Hour Rating1 | N/A 105 gal397 L | N/A 105 gal397 L | N/A 105 gal397 L | N/A 105 gal397 L | N/A 120 gal454 L | |||||
Recovery at 100 ºF Temperature Rise | N/A 58 U.S. gal/h48 Imp. gal/h | N/A 58 U.S. gal/h48 Imp. gal/h | N/A 58 U.S. gal/h48 Imp. gal/h | N/A 58 U.S. gal/h48 Imp. gal/h | N/A 63 U.S. gal/h52 Imp. gal/h | |||||
Recovery at 56 ºC Temperature Rise | N/A 220 L/h | N/A 220 L/h | N/A 220 L/h | N/A 220 L/h | N/A 238 L/h | |||||
Schematic |
N/A
Schematic Drawing for Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heaters |
|||||||||
Floor to Exhaust Outlet A | N/A 68 in1727 mm | N/A 68 in1727 mm | N/A 68 in1727 mm | N/A 68 in1727 mm | N/A 71-1/4 in1809 mm | |||||
Jacket Diameter B | N/A 22 in559 mm | N/A 22 in559 mm | N/A 22 in559 mm | N/A 22 in559 mm | N/A 24 in610 mm | |||||
Vent Size C | N/A 3 in76 mm | |||||||||
Floor to T and P Connection D | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 55-5/8 in1489 mm | |||||
Floor to Gas Connection E | N/A 13-5/8 in346 mm | |||||||||
Floor to Space Heating Return F | N/A 15-3/4 in400 mm | |||||||||
Floor to Space Heating Supply G | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 52-1/4 in1327 mm | N/A 55-5/8 in1489 mm | |||||
Floor to Air Intake H | N/A 67 in1701 mm | N/A 67 in1701 mm | N/A 67 in1701 mm | N/A 67 in1701 mm | N/A 69-1/2 in1765 mm | |||||
Floor to Water Connection J | N/A 59-3/4 in1517 mm | N/A 59-3/4 in1517 mm | N/A 59-3/4 in1517 mm | N/A 59-3/4 in1517 mm | N/A 63 in1600 mm | |||||
Depth K | N/A 32 in812 mm | N/A 32 in812 mm | N/A 32 in812 mm | N/A 32 in812 mm | N/A 34-1/8 in867 mm | |||||
Center Line Distance from Intake to Exhaust L | N/A 9-1/4 in235 mm | |||||||||
Approximate Shipping Weight | N/A 303 lb137 kg | N/A 303 lb137 kg | N/A 303 lb137 kg | N/A 303 lb137 kg | N/A 330 lb149 kg | |||||
AC Voltage | N/A 110 V | |||||||||
Frequency | N/A 60 Hz | |||||||||
Current | N/A 3.1 A | |||||||||
Maximum Intake Length for 3" Vent Pipe | N/A 60 ft | |||||||||
Maximum Exhaust Length for 3" Vent Pipe | N/A 60 ft | |||||||||
Minimum Vent Length for 3" Vent Pipe | N/A 7 ft | |||||||||
One 90º Elbows for 3" Vent Pipe | N/A 55 ft | |||||||||
Two 90º Elbows for 3" Vent Pipe | N/A 50 ft | |||||||||
Three 90º Elbows for 3" Vent Pipe | N/A 45 ft | |||||||||
Maximum Intake Length for 4" Vent Pipe | N/A 100 ft | |||||||||
Maximum Exhaust Length for 4" Vent Pipe | N/A 100 ft | |||||||||
Minimum Vent Length for 4" Vent Pipe | N/A 7 ft | |||||||||
One 90º Elbows for 4" Vent Pipe | N/A 95 ft | |||||||||
Two 90º Elbows for 4" Vent Pipe | N/A 90 ft | |||||||||
Three 90º Elbows for 4" Vent Pipe | N/A 85 ft | |||||||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Gas Connection | N/A 1/2 in13 mm | |||||||||
Style | N/A Light-Duty Power Direct Vent | |||||||||
Type | N/A Natural Gas | N/A Natural Gas | N/A Liquid Propane Gas | N/A Liquid Propane Gas | N/A Natural Gas | |||||
Size | N/A C | |||||||||
Industry Standards | N/A AHRI Certified® ANSI CSA® Certified | |||||||||
Features |
N/A
The LD Power Direct Vent FVIR Defender Safety System® Models Feature:
|
|||||||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All water connections are 3/4" NPT (19 mm) on 11" (203 mm) centers. All gas connections are 1/2" (13 mm). All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. |
|||||||||
Warranty |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Note |
N/A
110 V.A.C Required for Power Venting / 110 V.A.C., 60 HZ, 3.1 Amperes. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Recovery Efficiency. |
N/A
110 V.A.C Required for Power Venting / 110 V.A.C., 60 HZ, 3.1 Amperes. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Recovery Efficiency. |
N/A
110 V.A.C Required for Power Venting / 110 V.A.C., 60 HZ, 3.1 Amperes. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Recovery Efficiency. Propane models feature a Titanium Stainless Steel propane burner. |
N/A
110 V.A.C Required for Power Venting / 110 V.A.C., 60 HZ, 3.1 Amperes. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Recovery Efficiency. Propane models feature a Titanium Stainless Steel propane burner. |
N/A
110 V.A.C Required for Power Venting / 110 V.A.C., 60 HZ, 3.1 Amperes. Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Recovery Efficiency. |
|||||
|