Manufacturer |
N/A State® |
Tank Capacity |
N/A 119 gal450 L |
Standard Input Power |
N/A 13.5 kW |
Input Power |
N/A 46075 BTU/hr |
Inlet/Outlet (NPT) |
N/A 1-1/4 in3.2 cm |
Approximate Shipping Weight |
N/A 390 lb177 kg |
Number of Elements |
N/A 3 |
Element Power |
N/A 4500 W |
Voltage |
N/A 208 V240 V277 V480 V |
Phase |
N/A Single Three |
Working Pressure |
N/A 150 psi1034 kPa |
Style |
N/A Sandblaster® Surface Mount |
Size |
N/A C |
Type |
N/A Electric |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified cUL® Listed UL® Listed |
Recovery at 30 ºF Temperature Rise |
N/A 184 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 698 L/h |
Recovery at 40 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 523 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 111 gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 419 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 92 gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 349 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 79 gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 299 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 69 gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 262 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 62 gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 233 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 55 gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 209 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 50 gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 190 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 46 gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 174 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 43 gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 161 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 40 gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 150 L/h |
Full Load Current Single Phase 208 V |
N/A 64.9 A |
Full Load Current Single Phase 240 V |
N/A 56.3 A |
Full Load Current Single Phase 277 V |
N/A 48.7 A |
Full Load Current Single Phase 480 V |
N/A 28.1 A |
Full Load Current Three Phase 208 V |
N/A 37.5 A |
Full Load Current Three Phase 240 V |
N/A 32.5 A |
Full Load Current Three Phase 480 V |
N/A 16.2 A |
Features |
N/A
Meets the current edition of ASHRAE/IESNA 90.1 standards. Gold Elements - CSB models ship with the gold plated elements. Patented gold elements provide long life and superior scaling resistance. Low watt density means lower surface temperature to minimize scale buildup and more surface to heat water. Gold elements carry a one-year warranty against failure due to lime scale build-up. Glasslined Tank - Three sizes: 50, 80, and 119 gallon capacity. Tank interior is coated with glass specially developed for water heater use. Tanks rated at 150 psi (1034 kPa) working pressure (ASME 150 psi). Foam insulation reduces costly heat loss, and is vermin proof. Fusing - Protects all elements, thermostats, and internal wiring circuits against excess current flow. Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps. Standard Voltages - 208, 240, and 480 V single-phase and three-phase delta. Convertible from three-phase to single -phase (in field) and vice versa. 277 V single-phase also available. Terminal Block - Factory-installed. Just bring the service to the heater and connect to block. Controls - One temperature control (adjustable through a range of 120 to 180 ºF) and manual reset high temperature cut-off per element. Thermostat step control may be achieved by varying settings on individual temperature controls. Located behind hinged control compartment door for quick, easy access. |
Other Standard Features |
N/A
|
Options |
N/A
|