Catalog
State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
State®
Unit of Measure
Items |
/Asset/a1133.jpg TPO 150 720 OEA TPO Power Oil Large Volume Commercial Water Heater |
/Asset/a1133.jpg TPD 150 720 ONEA TPD Power Dual-Fuel Large Volume Commercial Water Heater |
/Asset/a1133.jpg TPG 150 140 NEA TPG Power Gas Large Volume Commercial Water Heater |
/Asset/a1133.jpg TPG 150 199 NEA TPG Power Gas Large Volume Commercial Water Heater |
/Asset/a1133.jpg TPG 150 255 NEA TPG Power Gas Large Volume Commercial Water Heater |
|||||
Description |
N/A
TPO - Oil Fired Models: No. 1 or 2 Oil
|
N/A
TPD - Dual-Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil
|
N/A | N/A | N/A | |||||
Manufacturer | N/A State® | |||||||||
Nominal Storage Capacity | N/A 145 U.S. gal | N/A 145 U.S. gal | N/A 150 U.S. gal | N/A 150 U.S. gal | N/A 150 U.S. gal | |||||
Input Power | N/A 720000 BTU/hr | N/A 720000 BTU/hr | N/A 140000 BTU/hr | N/A 199000 BTU/hr | N/A 255000 BTU/hr | |||||
First Hour Rating | N/A 5.1 gal | N/A 5.1 gal | N/A 256 gal | N/A 313 gal | N/A 367 gal | |||||
Recovery at 80 ºF Temperature Rise | N/A 873 gal/h | N/A 873 gal/h | N/A 170 gal/h | N/A 241 gal/h | N/A 359 gal/h | |||||
Recovery at 100 ºF Temperature Rise | N/A 698 gal/h | N/A 698 gal/h | N/A 136 gal/h | N/A 193 gal/h | N/A 247 gal/h | |||||
Recovery at 140 ºF Temperature Rise | N/A 416 gal/h | N/A 416 gal/h | N/A 97 gal/h | N/A 138 gal/h | N/A 176 gal/h | |||||
Schematic |
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPO) |
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPD) |
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG) |
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG) |
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG) |
|||||
Dimension A | N/A 82-1/4 in | |||||||||
Dimension B | N/A 14 in | |||||||||
Dimension C | N/A | N/A 1-1/4 in | N/A 1/2 in | N/A 1/2 in | N/A 1/2 in | |||||
Dimension D | N/A 27-3/4 in | N/A 27-3/ 4 in | N/A 27-3/4 in | N/A 27-3/4 in | N/A 27-3/4 in | |||||
Dimension E | N/A 1-1/4 in | |||||||||
Dimension F | N/A 36-1/2 in | |||||||||
Dimension G | N/A 10 in | N/A 10 in | N/A 5 in | N/A 6 in | N/A 6 in | |||||
Dimension H | N/A 57-1/2 in | N/A 57-1/2 in | N/A 47 in | N/A 47 in | N/A 47 in | |||||
Dimension J | N/A 73 in | |||||||||
Shipping Weight with Burner | N/A 1510 lb | N/A 1510 lb | N/A 1292 lb | N/A 1292 lb | N/A 1292 lb | |||||
Motor Power | N/A 1/4 hp | N/A 1/4 hp | N/A 1/7 hp | N/A 1/7 hp | N/A 1/7 hp | |||||
Current | N/A 4.6 A | N/A 4.6 A | N/A 2.5 A | N/A 2.5 A | N/A 2.5 A | |||||
Voltage | N/A 120 V | |||||||||
Frequency | N/A 60 Hz | |||||||||
Type | N/A Gas | N/A Gas | N/A Natural Gas | N/A Natural Gas | N/A Natural Gas | |||||
Style | N/A State Titan® Power Low NOx | N/A State Titan® Power Low NOx | N/A State Titan® Large Volume | N/A State Titan® Large Volume | N/A State Titan® Large Volume | |||||
Size | N/A C | |||||||||
Industry Standards | N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed | |||||||||
Features |
N/A
|
|||||||||
Other Features |
N/A
|
|||||||||
Note |
N/A
Certified Minimum Installation Clearances to Combustibles:
State Titan TPO models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent. |
N/A
Certified Minimum Installation Clearances to Combustibles:
State Titan TPD models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent. |
N/A
Certified Minimum Installation Clearances to Combustibles:
Minimum gas supply pressure: 7 Inches W.C. Maximum gas supply pressure: 13 Inches W.C. TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent. |
N/A
Certified Minimum Installation Clearances to Combustibles:
Minimum gas supply pressure: 7 Inches W.C. Maximum gas supply pressure: 13 Inches W.C. TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent. |
N/A
Certified Minimum Installation Clearances to Combustibles:
Minimum gas supply pressure: 7 Inches W.C. Maximum gas supply pressure: 13 Inches W.C. TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent. |
|||||
|