Items |
GPV85 540 NEA Titan™ Power Burner Low NOx Commercial Gas Water Heaters |
GPV85 650 NEA Titan™ Power Burner Low NOx Commercial Gas Water Heaters |
GPV85 740 NEA Titan™ Power Burner Low NOx Commercial Gas Water Heaters |
GPG85 540 NEA Titan™ Power Burner Low NOx Commercial Gas Water Heaters |
GPG85 650 NEA Titan™ Power Burner Low NOx Commercial Gas Water Heaters |
|||||
Manufacturer | N/A State® | |||||||||
Input Power | N/A 540000 BTU/hr | N/A 650000 BTU/hr | N/A 740000 BTU/hr | N/A 540000 BTU/hr | N/A 650000 BTU/hr | |||||
Tank Capacity | N/A 321.7 L | N/A 321.7 L | N/A 321.7 L | N/A 85 U.S. gal | N/A 85 U.S. gal | |||||
First Hour Rating at 100 ºF Temperature Rise | N/A 2206.7 L | N/A 2611.7 L | N/A 2944.7 L | N/A 583 U.S. gal | N/A 690 U.S. gal | |||||
Recovery at 40 ºF Temperature Rise | N/A | N/A | N/A | N/A 1309 gal/h | N/A 1579 gal/h | |||||
Recovery at 4 ºC Temperature Rise | N/A 4954.6 L/h | N/A 5976.5 L/h | N/A 6790.3 L/h | N/A | N/A | |||||
Recovery at 100 ºF Temperature Rise | N/A | N/A | N/A | N/A 523 gal/h | N/A 630 gal/h | |||||
Recovery at 56 ºC Temperature Rise | N/A 1979.6 L/h | N/A 2384.6 L/h | N/A 2717.6 L/h | N/A | N/A | |||||
Recovery at 140 ºF Temperature Rise | N/A | N/A | N/A | N/A 374 gal/h | N/A 450 gal/h | |||||
Recovery at 78 ºC Temperature Rise | N/A 1415.6 L/h | N/A 1703.3 L/h | N/A 1937.9 L/h | N/A | N/A | |||||
Schematic |
N/A
Schematic Drawing for Titan™ Power Burner Low NOx Commercial Gas Water Heaters (GPV Models) |
N/A
Schematic Drawing for Titan™ Power Burner Low NOx Commercial Gas Water Heaters (GPV Models) |
N/A
Schematic Drawing for Titan™ Power Burner Low NOx Commercial Gas Water Heaters (GPV Models) |
N/A
Schematic Drawing for Titan™ Power Burner Low NOx Commercial Gas Water Heaters (GPG Models) |
N/A
Schematic Drawing for Titan™ Power Burner Low NOx Commercial Gas Water Heaters (GPG Models) |
|||||
Dimension A | N/A | N/A | N/A | N/A 80-3/4 in2051 mm | N/A 80-3/4 in2051 mm | |||||
Dimension B | N/A | N/A | N/A | N/A 73 in1854 mm | N/A 73 in1854 mm | |||||
Dimension C | N/A | N/A | N/A | N/A 32-1/4 in819 mm | N/A 32-1/4 in819 mm | |||||
Dimension D | N/A | N/A | N/A | N/A 9 in229 mm | N/A 9 in229 mm | |||||
Dimension E | N/A | N/A | N/A | N/A 6 in152 mm | N/A 8 in203 mm | |||||
Dimension F | N/A | N/A | N/A | N/A 26-1/2 in673 mm | N/A 26-1/2 in673 mm | |||||
Dimension G | N/A | N/A | N/A | N/A 93 in2362 mm | N/A 93 in2362 mm | |||||
Dimension H | N/A | N/A | N/A | N/A 29-1/2 in749 mm | N/A 29-1/2 in749 mm | |||||
Dimension I | N/A | N/A | N/A | N/A 48-1/2 in1232 mm | N/A 48-1/2 in1232 mm | |||||
Gas Connection | N/A | N/A | N/A | N/A 1 in25.4 mm | N/A 1 in25.4 mm | |||||
Type | N/A Natural Gas | |||||||||
Style | N/A State Titan® | |||||||||
Size | N/A C | |||||||||
Approximate Shipping Weight | N/A | N/A | N/A | N/A 950 lb431 kg | N/A 950 lb431 kg | |||||
Industry Standards | N/A AHRI Certified® ASME Certified CSA® Certified Start-Up UL® Listed | |||||||||
Maximum Working Pressure | N/A 160 psi | |||||||||
Features |
N/A
Powered Gas Low NOx Burner (Natural Gas Only)
Factory-Installed CSA Certified and ASME Rated T & P Relief Valve Glasslined Tank
Handhole Cleanout
|
|||||||||
Testing and Certifications |
N/A
|
|||||||||
Warranty |
N/A
|
|||||||||
Note |
N/A
Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 5.0 amps, use 15 amps supply power. |
N/A
Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 5.0 amps, use 15 amps supply power. |
N/A
Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 5.0 amps, use 15 amps supply power. Minimum gas supply pipe size is 1 1/4". Maximum supply gas pressure 14" W.C. |
N/A
Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120 V, 60 Hz, 1 Phase): 5.0 amps, use 15 amps supply power. Minimum gas supply pipe size is 1 1/4". Maximum supply gas pressure 14" W.C. |
N/A
Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 4% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 5.0 amps, use 15 amps supply power. Minimum gas supply pipe size is 1 1/4". Maximum supply gas pressure 14" W.C. |
|||||
|